butterfly valve VitonStandardSize: DN40-DN1200 Place of Origin: China (Mainland)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 9999 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Standard or Nonstandard: Standard Structure: Butterfly Pressure: Low Pressure Power: Manual Material: Casting Temperature of Media: Normal Temperature Media: Water Port Size: DN40-DN1200 Place of Origin: China (Mainland) Wafer type: butterfly valve Packaging & Delivery
Packaging Details: Plactic bag+Paper cover+Plywood cases
Delivery Detail: Within 20 days
Specifications
Wafer type lined butterfly valve
1.Design standard:ISO,BS,API
2.DN40-DN1200
3.PN10/PN16/PN25
4.Center lined disc
Wafer type lined butterfly valve
Technical Data
DN40-DN1200mm PN1.0-1.6MPa
General Design:ISO 5752 / BS 5155 / API 609
Body: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel
Seat: EPDM, PTFE, NBR,Viton
Stem: Stainless Steel, Steel,
Disc: Ductile Iron with Nickel Coating,Ductile Iron with Nylon Coating, Stainless Stee 304/316l, Alu-Bronze,Duplex steel
Flange Connection:DIN,ANSI,JIS,BS
Product Features
Wafer type flanged body style fit between FF or RF flanges
PTFE bushing ensure the maximum shaft support and centralized alignment
360°polished disc assures positive on-off
Hard-Backed Cartridge seat or Edge-Boot seat
The pin,spline or square connection are all available
Universal ISO 5211 mounting pad.
- Q: What's the use of fire butterfly valve?
- Fire butterfly valve is the abbreviation of fire signal butterfly valve, which belongs to a kind of fire valve.Fire valve is an important accessory on the industrial and building pipelines. The fire fighting valve is composed of three parts: valve body, headstock gear and valve cover. Among them, the fire signal butterfly valve has the advantages of simple structure, reliable sealing, light opening, long life, convenient maintenance and so on. It is widely used in water supply and drainage, building, fire fighting systems, all kinds of pipelines, especially in fire lines.
- Q: I am confused as to the answer of this question. Please help.Indicate the status of the mitral, tricuspid and semilunar valves (whether they are open or closd) during the various phases of the cardiac cycle. Discuss the pressure in each of the relevant chambers or blood vessels during the phases with reference to the opening or closing of the valves.
- A heartbeat is a two-part pumping action that takes about a second. As blood collects in the upper chambers (the right and left atria), the heart's natural pacemaker (the SA node) sends out an electrical signal that causes the atria to contract. This contraction pushes blood through the tricuspid and mitral valves into the resting lower chambers (the right and left ventricles). This part of the two-part pumping phase (the longer of the two) is called diastole. The second part of the pumping phase begins when the ventricles are full of blood. The electrical signals from the SA node travel along a pathway of cells to the ventricles, causing them to contract. This is called systole. As the tricuspid and mitral valves shut tight to prevent a back flow of blood, the pulmonary and aortic valves are pushed open. While blood is pushed from the right ventricle into the lungs to pick up oxygen, oxygen-rich blood flows from the left ventricle to the heart and other parts of the body. After blood moves into the pulmonary artery and the aorta, the ventricles relax, and the pulmonary and aortic valves close. The lower pressure in the ventricles causes the tricuspid and mitral valves to open, and the cycle begins again. This series of contractions is repeated over and over again, increasing during times of exertion and decreasing while you are at rest. The heart normally beats about 60 to 80 times a minute when you are at rest, but this can vary. As you get older, your resting heart rate rises. Also, it is usually lower in people who are physically fit.
- Q: Ok, so I took my car in for maintenance (Mustang GT convertible 2002) and the mechanic told me the valve gaskets needed to be replaced and when he gave me the estimate, they were two seperate charges for valve gaskets and valve covers, total of about $250.00 not including labor. Is he trying to rip me off cause I'm a girl by the way? Anyways, I didn't get it done cause it needed something else too and I didn't have enough money so I said I would be back in two weeks. So I called the dealership to inquire about the price and I asked the parts guy for a price on valve gaskets and he was like, I don't know what you mean, we have valve cover gaskets but nothing says just valve gaskets? I told him to give me the price anyways, thinking I would ask my brother (who hasn't tried to help me anyways) and it was $60.00 for both (I need two). How can this be if the other guy was charging me $250.00 for different parts? Help!!! Frustrated and confused, I don't know anything about cars :(
- here okorder /... usually you can tell when a car needs the gasket to be replaced because it will leak oil where the gasket is at the bottom of the cover i think hes ripping you off because cars usually dont need to have the valve cover replaced, just the gaskets so take it to another mechanic and get another estimate
- Q: Model specification for butterfly valves
- 1. classification by structure(1) Central sealed butterfly valve (2) single eccentric sealed butterfly valve (3) double eccentric sealed butterfly valve (4) three eccentric sealed butterfly valve2. by secret cover material classification(1) soft sealing butterfly valve. (2) metal hard sealing butterfly valve.3. classified by seal type(1) forced sealing butterfly valve (2) pressure sealed butterfly valve. (3) automatic sealing butterfly valve. The pressure of the seal is automatically generated by the pressure of the medium.4. classification by work pressure(1) vacuum butterfly valve. Butterfly valve with lower working pressure than standard atmosphere. (2) low pressure butterfly valve. Butterfly valve with nominal pressure PN<1.6MPa. (3) medium pressure butterfly valve. Butterfly valve with nominal pressure PN 2.5--6.4MPa. (4) high pressure butterfly valve. Nominal pressure PN is 10. 0--80.0MPa butterfly valve. (5) ultra high pressure butterfly valve. Butterfly valve with nominal pressure PN>100MPa.5. classification by operating temperature(1) high temperature butterfly valve. T>450 degrees C butterfly valve (2) medium temperature butterfly valve. 120 C6. classification by connection1 pairs of clip butterfly valve2, flange butterfly valve (3) lug butterfly valve. (4) welded butterfly valve.
- Q: How does the pneumatic butterfly valve control the angle of opening?
- This is really not good, control seems to be pneumatic defects, can only rely on the feeling
- Q: Specifically an engine valve retainer.
- There okorder for year make model engine valve diagram and you should find a drawing of your setup.
- Q: Butterfly valves are widely used in 2.0MPa below the pressure and temperature of not more than 200 degrees of various media, right?
- 5. butterfly valve structureButterfly valve mainly by the body, butterfly plate, stem, sealing ring and transmission components.(1) the valve body is cylindrical, and the upper and lower parts each have a cylindrical boss for installing the valve stem. Butterfly valve and pipe flange connection, such as the use of clamp connection, the minimum length of its structure.(2) stem, stem is the axis of the butterfly plate, shaft end adopts stuffing box sealing structure, can prevent leakage of medium. The upper end of the valve stem is directly connected with the driving device to transmit the torque.(3) the butterfly plate is the opening and closing part of butterfly valve.
- Q: Butterfly valve in the use of the difference? Caliber?
- According to the function and use of the valve and butterfly valve, gate valve, small flow resistance, good sealing performance, the valve plate and the flow direction of the medium is the vertical angle, if the valve is not in place in the valve plate switch, wash medium on the valve plate of the valve plate is easy to fibrillation, according to valve seal damage.Also known as butterfly valve, control valve has a simple structure, can be used for low pressure pipeline valve switching control is closed parts (disc or disc) is a disk, around the valve axis to achieve the opening and closing a valve, the valve can be used to control the flow of air, water, steam steam, all kinds of corrosive medium, mud, oil, metals and radioactive liquid media and other types of fluid. On the pipeline, mainly from cutting and throttling. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
- Q: DN80 flange butterfly valve, DN80 flange butterfly valve DN80, flange butterfly valve DN80 what is the difference?
- No, what's the difference?. It's not all the same.Flange connectionDN80 caliber butterfly valve. What's the difference?. Model and pressure. Materials are not ~!
- Q: What are the uses and classifications of manually operated clip butterfly valves?
- In the butterfly valve body cylindrical channel, the disc shaped butterfly plate revolves around the axis, the rotation angle is 0 degrees -90 degrees between, when rotates to 90 degrees, the valve opens the card completely. Butterfly valves are not only widely used in petroleum, gas, chemical, water treatment and other general industries, but also applied to the cooling water system of thermal power stations.
Send your message to us
butterfly valve VitonStandardSize: DN40-DN1200 Place of Origin: China (Mainland)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 9999 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords