butterfly valve NBR StandardSize: DN40-DN1200 Place of Origin: China (Mainland)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 9999 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Standard or Nonstandard: Standard Structure: Butterfly Pressure: Low Pressure Power: Manual Material: Casting Temperature of Media: Normal Temperature Media: Water Port Size: DN40-DN1200 Place of Origin: China (Mainland) Wafer type: butterfly valve Packaging & Delivery
Packaging Details: Plactic bag+Paper cover+Plywood cases
Delivery Detail: Within 20 days
Specifications
Wafer type lined butterfly valve
1.Design standard:ISO,BS,API
2.DN40-DN1200
3.PN10/PN16/PN25
4.Center lined disc
Wafer type lined butterfly valve
Technical Data
DN40-DN1200mm PN1.0-1.6MPa
General Design:ISO 5752 / BS 5155 / API 609
Body: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel
Seat: EPDM, PTFE, NBR,Viton
Stem: Stainless Steel, Steel,
Disc: Ductile Iron with Nickel Coating,Ductile Iron with Nylon Coating, Stainless Stee 304/316l, Alu-Bronze,Duplex steel
Flange Connection:DIN,ANSI,JIS,BS
Product Features
Wafer type flanged body style fit between FF or RF flanges
PTFE bushing ensure the maximum shaft support and centralized alignment
360°polished disc assures positive on-off
Hard-Backed Cartridge seat or Edge-Boot seat
The pin,spline or square connection are all available
Universal ISO 5211 mounting pad.
- Q: I got my timing belt done on a 1999 Civic Si on September 26 @ 113,699 miles. at 116,9xx miles I bent a valve on my third cylinder. How likely is it that the timing belt is the reason why this happened? I heard that if the timing belt is a tooth or so off, it could bend a valve. So is it likely that this could have happened? Anyway to check?
- If it was a timing belt issue it woudn't have only been one cylinder. And usually if it's only off by one tooth, it just runs poorly. IT has to be off by quite a bit, or the belt has to straight up break to bend a valve,, if that happened it would have made a horrible clanging noise repeatedly before it eventually sputtered out. the 1999 Si revs to what... 8000 rpms? You didn't happen to miss a shift and over-rev the engine, did you?
- Q: What is the difference between turbine butterfly valve and flanged butterfly valve?
- The worm gear is the driving mode and corresponds to the handle; the flange is connected and corresponds to the clamp. Flange worm valve is generally, the handle of the butterfly valve
- Q: The difference between butterfly valve and gate valve
- Its varieties and quantities are still expanding, and the development of high temperature, high pressure, large caliber, high sealing, long life, excellent regulation, as well as multi-function development of one valve. Its reliability and other performance indicators have reached a high level. Disadvantages, there is a certain resistance to the medium. Gate valves are more used in steam pipes and large diameter water supply pipelines, because of the general requirements of fluid resistance is small, the use of gate valve. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open. Need a higher installation space, the valve sealing surface has a certain self sealing capacity, its spool by the media pressure closely with the valve seat sealing surface contact, to achieve tight leakage.
- Q: In the pipeline attached building Atlas 05S502, in the middle of a water meter and check valve, the two sides are divided into two butterfly valve, want to ask why to arrange this way, what is the role of the two butterfly valve?
- Check the water gauge and check valve on both sides to facilitate the maintenance and replacement of water meter and check valve.
- Q: Function of signal butterfly valve in fire sprinkler system
- The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance; two is the sprinkler system is not allowed inside water, when the butterfly is closed, will transmit a signal to the the fire alarm system, fire alarm system receives a monitoring signal (so called signal butterfly valve), fire sprinkler system that the floor is anhydrous state, fast repair.Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
- Q: Is the pressure test of the centerline butterfly valve checked or checked?
- The pressure test of the central butterfly valve is carried out at each station.Basis:1) GB/T12238-2008 flange and clamp connection elastic seal butterfly valveRules: butterfly valve must be carried out by factory inspection and testing, inspection qualified before leaving the factory.2) CJ/T 261-2007, butterfly valves for water supply and drainageRules: each product shall be inspected by factory and quality inspection department. After inspection, the product certificate shall be attached to the factory.Butterfly: also known as butterfly valve, control valve has a simple structure, can be used for low pressure pipeline valve switching control is closed parts (disc or disc) is a disk, around the valve axis to achieve the opening and closing a valve, the valve can be used to control air, water, steam, all kinds of corrosive media, mud, oil, metals and radioactive liquid media and other types of fluid flow. On the pipeline, mainly from cutting and throttling. Butterfly valve headstock is a disc shaped disc, in the valve body around its own axis of rotation, so as to achieve the purpose of opening or closing or regulation.
- Q: For example, the arrow above is from left to right, and the direction of my current is from right to left. Is that ok? I have a diameter of 700 of the hard seal butterfly valve is so installed, but it will leak water, it will not leak, very serious
- The direction of the arrow on the valve body is cast, refers to the flow of media, users see the arrow, the arrow direction according to the logical and installation, this installation has become a habit, it is easy to accept the installation instructions, according to the national standard is not what error. But in the eccentric butterfly valve is installed so that sometimes there will be some problems, said the following example: according to the flow of eccentric butterfly valve with the medium flow consistent installation, tube medium is liquid, after the valve is closed, if the original direction of medium inlet pressure, reduced or zero, the export of medium reflux reflux, if senior supply, resulting in the high pressure medium, the pressure is greater than the inlet pressure, the valve will be subjected to reverse pressure, because the hard seal butterfly valve as a one-way valve so that the use is not conducive to sealing butterfly valve, and there will be leakage.
- Q: How to control the single acting pneumatic butterfly valve?
- Single acting pneumatic butterfly valve can be divided into gas open type and gas closed type, which is usually called "normally closed" and "normally open". This is very critical. The single feature pneumatic butterfly valve is the biggest feature of its spring reset function, when the loss of gas or sudden failure, you can automatically restore the original state. So it's important to open the air or air this time.
- Q: e.g. a patient with a prosthetic aortic valve and a patient with a prosthetic mitral valve. Also, can you get stenosis of mechanical valves or just tissue grafts?Thanks!
- mechanical okorder /
- Q: What is the difference between wafer (flangeless) type and LUG type of butterfly valves?
- WAFER butterfly valve is the valve is divided into LUG (ears) with and without LUG, ordinary LUG without clip on 12 points in the direction of valve is generally two to four bolt holes was not, whereas the LUG of butterfly valve cross dispersed in a circle. Bolt hole. With LUG all bolted through the LUG, so that the butterfly valve and the clamp on the two flange connection is more solid, you check the valve picture, it is easy to understand
Send your message to us