battery free maintenance battery 12v 38ah

battery free maintenance battery 12v 38ah

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
50 unit
Supply Capability:
450000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Place of Origin:                     Jiangsu, China (Mainland)

  • Brand Name:                      free maintenance battery

  • Model Number:                     LCPC38-12

  • Usage:                     UPS

  • Voltage:                     12v

  • Sealed Type:                     Sealed

  • Maintenance Type:                     Free

  • Size:                     196*165*180(mm)

  • Weight:                     12.8kg

  • Nominal Capacity:                     38AH

  • Type:                      free maintenance battery

  • self-discharge:                     <2%/month

  • packing:                     plywood case

  • HS Code:                     8507200000

  • product capacity:                     150000pcs/day

  • Factory:                     400000 square meter

  • export markets:                     America,Africa, Mid-east,Asia ,South America, Europe

Specifications

12v 38ah  free maintenance battery
1)CE,TLC,ROHS,ISO,CQC,MSDS
2)export experience 15 years
3)long lifetime and no leakage                           

Battery Construction


ComponentPositive plateNegative plateContainerSafety valveTerminalSeparator

 

Electrolyte

 

Raw MaterialLead dioxideLeadABSRubberCopperFiberglass

 

Sulfuric acid

 

  

1. Container/Cover: Made of  ABS Plastic from Taiwan

 

2. Negative Plates: Use the special PbCa alloy grids, optimize the recombination efficiency and less gassing.

 

3. Separator: Import high quality AGM separator.

 

4. Positive Plates: Thick PbCa grids minimize corrosion and prolong life.

 

5. Terminal post: Cooper material with maximum conductivity, enhance the high current rapidly.

 

6. Vent Valve: Allows the release of excess gas automatically for safety.

 

 

Q: How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q: What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q: How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q: What battery does the van use?
General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
Q: How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q: The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q: How does the battery increase the voltage?
You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Q: Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q: Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.