• AGM Battery the Eos Series Battery Eos-600 System 1
  • AGM Battery the Eos Series Battery Eos-600 System 2
  • AGM Battery the Eos Series Battery Eos-600 System 3
  • AGM Battery the Eos Series Battery Eos-600 System 4
  • AGM Battery the Eos Series Battery Eos-600 System 5
AGM Battery the Eos Series Battery Eos-600

AGM Battery the Eos Series Battery Eos-600

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 unit
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range summary


                                 

The Eos range products are designed as standby power for communication, power, military and broadcast and television system. Elegant design with high energy density, latest improved technology are adopted in this series,design life is 15+ years.

The Eos range batteries are ensured the quality with NARADA's QA system according to the ISO9001 standard.

Technical features


  • AGM technology is applied.

  • 15+ years design life under floating application and cycle life is above 1200 at 80% DOD under temperature 25oC.

  • Reliable seal performance, no acid spillage, recombination efficiency reach 99.9%

  • Initial capacity above 100%, the remaining capacity above 94% after storage for 3 months (25oC)

  • low float charge voltage. design (2.25V/cell, 25oC), extremely consistent float charge voltage

  • Flexible connectors and convenient installation

 

Type:

  Eos-600

Voltage:

  2V

Nominal Capacity:

  600Ah(C10)  600Ah(10 hours rate:)

Length:

  223mm

Width:

  184.5mm

Height:

  360.5mm

Height                                                with termial:

  372mm

Weight:

  35Kg

 

Compliant standards

  • IEC60896-21/22

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system ISO9001(TUV)

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main applications

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Other applications to provide integrated stored energy system

Products characteristics:

  • Recommended float charge voltage for 2V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate :< 2% per month at 77oF(25oC)

  • Design life: 15+ years at 77oF(25oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ

What is a AGM (Absorbed Glass Mat )Battery?

The newer type of sealed nonspillable maintenance free valve regulated battery uses "Absorbed Glass Mats", or AGM separators between the plates. This is a very fine fiber Boron-Silicate glass mat. These type of batteries have all the advantages of gelled, but can take much more abuse. These are also called "starved electrolyte.Ąą Just like the Gel batteries, the AGM Battery will not leak acid if broken.

What are the advantages of the AGM battery?

The advantages of AGM batteries are no maintenance, sealed against fumes, hydrogen, leakage, or non-spilling even if they are broken, and can survive most freezes. AGM batteries are "recombinant" ¨C which means the Oxygen and Hydrogen recombine inside the battery. These use gas phase transfer of oxygen to the negative plates to recombine them back into water while charging and prevent the loss of water through electrolysis. The recombining is typically 99+% efficient, so almost no water is lost. Charging voltages for most AGM batteries are the same as for a standard type battery so there is no need for special charging adjustments or problems with incompatible chargers or charge controls. Since the internal resistance is extremely low, there is almost no heating of the battery even under heavy charge and discharge currents. AGM batteries have a very low self-discharge rate (from 1% to 3% per month). So they can sit in storage for much longer periods without charging. The plates in AGM's are tightly packed and rigidly mounted, and will withstand shock and vibration better than any standard battery.


 

Q: How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q: How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q: How to determine the battery is good or bad?
Instrument test: the general use of battery discharge tester, the test instrument two positive and negative clamp were holding the battery positive and negative electrodes, press the test button to observe the test instrument instructions.
Q: How to deal with waste batteries?
In addition to lead-acid batteries, all kinds of batteries are dissolved in sulfuric acid, and then by means of ion resin from the solution to extract a variety of metals, raw materials obtained in this way than the heat treatment method is pure, so the market price is higher, and the battery contains 95% of the various substances can be extracted.
Q: What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q: Maintenance-free battery how to detect it?
Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
Q: What battery does the van use?
General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
Q: 80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q: What kind of battery is divided into?
At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
Q: What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords