• Lead Acid Battery the OPzS Series  6OPzS600 System 1
  • Lead Acid Battery the OPzS Series  6OPzS600 System 2
  • Lead Acid Battery the OPzS Series  6OPzS600 System 3
  • Lead Acid Battery the OPzS Series  6OPzS600 System 4
  • Lead Acid Battery the OPzS Series  6OPzS600 System 5
  • Lead Acid Battery the OPzS Series  6OPzS600 System 6
Lead Acid Battery the OPzS Series  6OPzS600

Lead Acid Battery the OPzS Series 6OPzS600

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
5000000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Lead Acid Battery the OPzS Series Introduction


OPzS Series Lead Acid batteries are designed with a combination of die-casting Tubular positive framework and superfluous electrolyte technologies to offer a very high level of reliability and a long service life.
OPzS batteries used special filter and proof design to ensure no acid fog runs over and burning proof, and also convenient examine and maintenance.
The specification of OPzS series batteries make it ideal for a wide range of applications such as Telecommunications, Photovoltaic System, Security System, emergency lighting and UPS.

 

 

 


Lead Acid Battery the OPzS Series  6OPzS600Lead Acid Battery the OPzS Series  6OPzS600



Type:

  6OPzS600

Voltage:

  2V

Nominal Capacity:

  600Ah(C10)  600Ah(10 hours rate:)

Length:

  145mm

Width:

  206mm

Height:

  646mm

Height with termial:

  646mm

Weight:

  35.3Kg

Lead Acid Battery the OPzS Series Feature:

  • Low maintenance

  • Super long service life

  • Transparent containers, convenient to observe

  • Special filter installation for acid fog proof

  • High quality and high reliability

  • Special pole sealed technology

  • DIN40736-1 compliant

  • 20 years float life at25oC

Lead Acid Battery the OPzS Series Compliant Standards :

  • IEC60896-11

  • Din standard

  • UL

  • Manufactured under system ISO9001(TUV) and ISO14001(DNV) by Narada

Lead Acid Battery the OPzS Series Battery Installation Compliant with:

  • EN 50272-2 or local equivalents

Lead Acid Battery the OPzS Series Main Application:

  • Telecommunications

  • Energy storage such as solar and wind system

  • Motive power applications

  • Railway and mining markets

  • Uninterruptible power supply (UPS)

  • Other floating and cycling applications

FAQ 


Is there a maximum temperature for charging lead acid batteries?

When charging lead acid batteries, the temperature should not exceed 120ĄăF. At this point the battery should be taken off charge and allowed to cool before resuming the charge process.

Are lead acid batteries recyclable?

Lead acid batteries are 100% recyclable. Lead is the most recycled metal in the world today. The plastic containers and covers of old batteries are neutralized, reground and used in the manufacture of new battery cases. The electrolyte can be processed for recycled waste water uses. In some cases, the electrolyte is cleaned and reprocessed and sold as battery grade electrolyte. In other instances, the sulfate content is removed as Ammonia Sulfate and used in fertilizers. The separators are often used as a fuel source for the recycling process.

What is battery cycle life?

One cycle of a battery is a discharge from full charge to full discharge and a return to full charge again. The total number of cycles a battery can perform before failure is called its Cycle Life. Moat battery manufacturers will not discus the Cycle Life of their product. Many advertised Deep Cycle batteries have not been tested, or, which is the case with cranking batteries, were never designed for long Cycle Life .


Q: How to repair the battery?
Charge the battery at constant voltage. It is the beginning of the time, using 0.1C ~ 0.25C current charge, to 16.2V later, by reducing the current method to maintain the charging voltage, until the charge current drops to 0.03C when the stop charging.
Q: How is the capacity of the battery defined?
General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: What is the meaning of the battery above 12v65Ah?
Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
Q: How should the battery be well maintained?
Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
Q: 80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q: The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
Q: What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q: Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords