• Automatic Door High Speed for Fashion Decoration System 1
  • Automatic Door High Speed for Fashion Decoration System 2
  • Automatic Door High Speed for Fashion Decoration System 3
Automatic Door High Speed for Fashion Decoration

Automatic Door High Speed for Fashion Decoration

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
2000 set
Supply Capability:
2400000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Automatic Doors

1.industrial rolling and automatic
2.fit for clean room
3.anti-insect and dustproof
4.high frequency opening
5.high speed

Product Use:
Winsion KJM -62 Rollway High Speed Door Workshop Roller Shutter China Automatic Door , special design for purifying the workshop access, opening in high-speed, turn off the signal to connect the air shower control system, achieve air shower, clean the dust quickly through the requirements, meet the needs about plant's environmental.
Applications:
>Indoors door
>Food industry,electronics, pharmaceutical protective door.
>People and the vehicle, large goods can pass.

Technical parameters:

1.Appearance: High-strength antioxidant aluminum alloy frame 120 × 130 mm, silver-white, meet the standard 6063-T6, cold rolled steel electrostatic spraying door cover, chassis.
2. Power performance: Germany SEW brake motor, power 0.55- 1.5KW, power supply 220V/380V, brake voltage is 220V.
3. Control system: imported microcomputer frequency conversion to control of electric box (Mitsubishi cpu).
4. Control voltage: safe low-voltage 24VDC.
5. Opening speed: open 0.8-1.5m / s / off 0.6-1.2m / s (frequency conversion can adjust the speed).
6. Door curtain material: imported high-density polyester fiber and the surface coating processing, thickness 0.8mm-1.5mm, variety colors can be choose.
7. Tensile strength: 5700/5100N/5cm, tear strength 900/80N.
8. Fire-proofing level: German standard MZD / NBL fire resistant.
9. Usage temperature: -10 °C +70 °C .
10. Transparent window: import PVC transparent crystal soft plate, thickness 1.5mm, rectangle or oval.
11. Wind resistant material: aluminum alloy wind resistant ribs, Sub-section connecting, easy to replace.
12. Wind resistant capability: 9m / s (50Pa standard 3 × 3).
13. Sealability: the bottom of the door curtain U-shaped balloon bags can tight fitting with the uneven ground, the seal strip on the both sides of the door can vermins-proof and dust-proof.
14. Security Configuration: Standard infrared opto-electrical protection, pressure balloon, warning lights, anti- collision column, power failure hand crank.


Technical Specification

Parameter

ES-90/SOGD-100

ES-100/SOGD-150

Range of the Door

Single-leaf

Double-leaf

Single-leaf

Double-leaf

Door Leaf max Weight

90kg

90kg x 2

120kg

120kg x 2

Door Width

700-1300mm

650-1050mm

750-1600mm

650-1250mm

Installation Type

Surface Mounting

Max Door Leaf Thickness

50mm

Motor

DC24V, 65W

Power Supply

AC220±10%, 50-60 Hz

Input Current (Standby)

0.095A

Input Current(Operation)

1.6A

Opening Speed

250-550mm/s (adjustable)

Closing Speed

250-550mm/s (adjustable)

Creep Speed

30-100mm/s (adjustable)

Hold-open Time

2-20s (adjustable)

Hold-Close Force

70N

Manual Pushing Force

<50n< span="">

<60n< span="">

Power Consumption

<150w< span="">

Ambient Temperature

-20+50 °C






Q: Please Help
Sorry to hear you are having a concern with the automatic passenger door on your 2004 Dodge Caravan. I checked for Technical Service Bulletins but could not find any concerns regarding the automatic door. You may want to consider having the vehicle diagnosed by your local authorized Dodge Service Department or a trusted mechanic. Lisa Customer Care Chrysler Group LLC
Q: Automatic door is how to do when someone came to the door?
Mainly by the door above the sensor, the sensor is generally two, a far-infrared, a microwave, far infrared light affected by the relatively large, so not stable, microwave self-induction moving objects can not Induction of prohibited objects, that is, if you stand in the middle of the door does not move, the door will automatically shut up to hold you, then the best way is to install the microwave sensor and then in the middle of the door to install a set of infrared on the radio Closing the door. Microwave sensors are currently more popular, and far out of the basic infrared has been eliminated.
Q: Meet the requirements of the fire door on both sides of the revolving door
Pass the height of 4 meters above the width of 5 meters can be manually manual, you can go to understand the next Stanley fire door
Q: There are several types of sensors for automatic doors
Dripping in the afternoon to eat
Q: I accidentally kicked off one of my garage door eyes. I turned it back on, but now the door will not operate. I push the button and it moves forward and right back, then the unit clicks a few times. Can anyone help me get this back in working condition. It was with the house when I bought it, and there is no manual, so any help will be appreciated
All you have to do is adjust the eye you kicked so it is in line with the other one. They should both have little lights on them and if I remember correctly, when both lights are on they are adjusted correctly.
Q: our idea was to put the circuit on a wrist band to operate the door
Is there security? If not, Then you don't need any circuits. If yes, RFID tags are well known, so what is new?
Q: How is my world automatic door?
Dig a 2 * 3 lattice on the ground
Q: I live in an aprtment. I have a garage that works automaticaly. I didnt realize that it wasnt opened all the way yet and backed into the door with my SUV. well the maintenance guy came and fixed it to the point tha it works going up and down automatically. BUT, when closed there is a gap . the door got dentted so its kind os slanted when down all the way. He said they gonna have the door people come look at it and bill me.What could the cost be. Its working but the bottom of the door is dented. so thats what needs to be fixed. the dent so the gap and be fixed. maintenance guy said probably need to replace one panel.
We have a term for things that are outta whack or unsquare its called :Racked;---for a pro to replace one panel--plan on $300 with the Service Call---If it looks like more then that--ask how much to replace the whole door and compare--if you dint agree with the price locate your own Pro for an estimate. Since you are paying for it dont be shy to ask the price before they do the repair.
Q: What is the price of the Bill automatic door?
Smooth automatic door of the basic working principle is: installed in front of the door sensor infrared emission tube emitting a beam of infrared light, in the detection area to form a radiation surface, the radiation surface for the detection area, the light will be reflected in the target into this In a region, the infrared receiver detects and sends an electrical signal that reflects the red light. The signal is amplified, plastic input microcomputer. The computer according to the set procedures to command the motor and drive mechanism to work, so that the door set by the program to open, accelerate, full speed, brake slowly, close. When the door is closed when the door will be back when the obstacles, until the barrier is closed. As can be seen from the previous narrative, and then add some control components, by the controller can achieve more smooth automatic doors performance.
Q: I am disabled and use a wheelchair. I have an injured arm that I am careful about using. A grocery store I go to locks all automatic doors after 10 pm, forcing customers to pull open the exit doors which are heavy and have no handles on them. They open automatically OUT when done shopping but to get in they expect you to open them manually. Forced to do this, I re injured my shoulder. I know that locking automatic doors is a violation of ADA codes. What pain and suffering damages should I seek? Arm is in pain every day. It has disrupted my life.
The store did no such violation. They have a right to close the doors at closing time and they always do this. In fact, in a mall, if you are not out on time, sometimes, you are forced to exit at the opposite end of the mall and then walk all the way around to your car. If you could not open the door yourself, you should have had the sense to go find help and ask for it. Your other option would be to pay closer attention to the time and be out before they close the automatic doors. You have no case. The store was not negligent and you would have to prove negligence in order to have a case. It is unfortunate that you hurt your arm but, you did it yourself by using poor judgment. The store had nothing to do with your decision to try and open a door with your injured arm, which you knew was already injured.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords