3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase
1.Reliability
2.Interface-friendly
3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase
Product Discription
The power adopts advantaged SPWM IGBT high-frequency inverter technology, internal structure is AC-DC-AC, thoroughly eliminate the network interference, output waveforms are pure. It has the following features: wide range of constant-voltage and constant-frequency, high precision, light weight, small capacity, output transformer with apartheid, with the good with a high quality uninterrupted power supply system.
1.Input voltage: 130~280V
2.Input frequency: 30~70Hz
3.Output voltage: 220V/380V±0.5%
4.Output frequency:50Hz±0.01%
5.Wave distortion: <1%
6.Isolation transformer output, safe and credible
7.Auto-protection and alarm for output overvoltage, over current, overheat, short circuit
8.Efficiency reach above 90% ,widely applicable load,for nasty, capacitive resistance,any combination of the load
Product Parameter
Model | 11005 | 11010 | 11030 | 11050 | 11100 | 31150 | 31200 | 313000 | 31450 | 311000 | ||
Capacity(VA) | 500 | 1K | 3K | 5K | 10K | 15K | 20K | 30K | 45K | 100K | ||
Output currency | 2.1 | 4.2 | 12 | 21 | 42 | 63 | 84 | 125 | 188 | 420 | ||
Circuit model | IGBT/SPWM pulse width adjustment mode | |||||||||||
AC Input | Voltage | 130V-280V | 265V-495V | |||||||||
Frequency | 30-70Hz | |||||||||||
Phase | single phase | three phase four wire | ||||||||||
AC output voltage | 220V±1% | |||||||||||
Output frequency | 50Hz/60Hz | |||||||||||
frequency stability | ≤±0.01% | |||||||||||
Voltage stability | ≤1% | |||||||||||
Wave distortion | ≤2% | |||||||||||
Reaction time | ≤2mS | |||||||||||
frequency meter | 0.1Hz | |||||||||||
Voltage meter | 0.1V | |||||||||||
Current meter | 0. 1A | |||||||||||
Power meter | 0.1W | |||||||||||
Efficiency | efficiency more than 90% ,be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads. | |||||||||||
Protection function | The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage Express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm. | |||||||||||
Insulation reactance | 500Vdc 20MΩ | |||||||||||
Pressure endurance insulation | 1500Vac/5mA/1min | |||||||||||
Cooling model | Compulsive fan cooling | |||||||||||
Working temperature | -10℃-45℃ | |||||||||||
Relative humidity | 0-90%(No condensing) | |||||||||||
Altitude | 1500meters | |||||||||||
Dimension (W×L×H)mm | 410*440*135 | 460*440*220 | 560*350*600 | 660*400*700 | 830*450*1100 | 1160*520* 1370 |
FAQ
What is the delivery time?
We can delivery the equipment within 5 days after receiving your payment.
- Q:Motor a speed, the inverter will burn what is going on, the inverter is a large yuan
- If you buy the inverter and the motor can match, it is certainly the quality of the inverter.
- Q:What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- The frequency changer mainly consists of rectifying (alternating current direct current), filtering, re-rectifying (direct current alternating current), braking unit, driving unit, detecting unit micro-processing unit and so on. Motor asynchronous speed expression bit: N = 60 f (1-s) / p (1) Where n --- the speed of asynchronous motor; f --- the frequency of asynchronous motor; s --- motor slip; p --- motor pole pairs. From the formula (1) we can see that the output speed of the motor is related to the input power frequency, slip rate and the number of pole pairs of the motor. Therefore, the direct speed regulation mode of AC motor mainly has variable speed (adjustment P), rotor Resistance speed control or cascade speed or internal feedback motor (adjust s) and frequency control (adjust f) and so on. And we now use the most widely used is the frequency control, from the speed n is proportional to the frequency f, as long as the change in frequency f can change the motor speed, when the frequency f in the range of 0 ~ 50Hz, the motor speed adjustment range is very width. The inverter is to change the motor power frequency to achieve speed adjustment, is an ideal high efficiency, high performance speed control means.
- Q:Oil-free vertical vacuum pump why a little negative pressure inverter on the torque limit
- and then use the inverter into three-phase AC, 380 volts almost, Can only use the transformer rose to 380 volts.
- Q:Why the number of motor poles increased, the inverter capacity will increase
- The relationship between the motor current and the power is The power is equal to the current and voltage of the product again good with the power factor. (Simplex)
- Q:Laptop warranty period is not over, the power adapter is broken, repair money?
- Have to admit that the emergence of Thinkpad x100e, will hit the Internet completely decent, this product is not the name of the Internet, but "ultra-portable notebook", which also shows the x100e relentless and the Internet is willing to belong to similar products. It can be said, x100e is turned out in 2010 turned out professional jet client!
- Q:Master Hello a machine requires 500 speed matching 6-pole motor frequency converter transferred to about 28HZ
- 6-pole motor synchronous speed of 1000 r / min, the actual motor speed is lower than the number, the actual speed is required to 500 r / min, then the motor and passive pulley diameter ratio of about 1: 1.6 or so, and then specific With the inverter to speed up to achieve the purpose, please refer to.
- Q:Laptop computer about electricity no electricity, is the power adapter problem?
- To judge this is very simple: 1. The computer is in the battery state to see if it works properly. If it does not work, the battery has a problem 2. Remove the battery from the computer with a power adapter to see if it is working properly. If not, there is a problem with the power adapter 3. If the two states can work that is the computer charge management part of the poor contact and other issues.
- Q:The laptop's power adapter can be used on a desktop computer
- Desktop machine is called DIY it ~ is the assembly machine inside the motherboard graphics card hard drive memory What is the need for power supply every power to have a different interface
- Q:Can the inverter be used to control the speed of the DC motor?
- For the brush commutation DC motor, the speed of the output torque in a certain circumstances and the input voltage related. For this type of motor, use the inverter to control the output of the rectifier device that supplies power to the motor, which can control the speed. For the brushless DC motor, the controller is in accordance with a certain law to change the form of stator winding power supply to produce a rotating magnetic field to drive the rotor rotation. That is, the DC motor controller outside the part of the AC motor and the structure and the principle has not much difference (see below. For such motors, with the inverter to replace the controller, and control the same as the AC motor Control the speed.
- Q:Notebook power adapter on how to look at power
- It should be noted that there are many in Japan to buy a notebook or over there in the parallel imports, input only support 110V in China is not used, because the Chinese standard is 220V. Now the subject is 90W 20V. Output voltage and power will be identified, such as the target for the 90W 20V, that output power is 90W, the output voltage is 20V. If only the output voltage and output current are identified,
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 100 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords