Without Holding Brake Plug Set MR-CCN1 Motor Part For Servo Amplifier
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 100 kg/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Brand: Mitsubishi
Product Name: plug set model: mr-ccn1
Content: servo amplifier connector.
Purpose: for mr-je-b input and output signals. Motor series: low inertia, small
capacity. Use serial pair / incremental encoder. Rated output power: 0.1kw.
Rated speed: 3000rpm. With or without holding brake: without holding brake.
Without GB.
Shaft end: straight shaft Mitsubishi mr-ccn1.
The rotor inside the servo motor is a permanent magnet. Unw two-phase
electricity controlled by the servo amplifier forms an electromagnetic field.
The rotor rotates under the action of this magnetic field. At the same time,
the motor and its own encoder feed back signals to the driver. The driver
compares the feedback value with the target value and adjusts the rotation
angle of the rotor mr-ccn1
The accuracy of servo motor depends on the resolution of encoder. Servo motor
series: medium inertia, small capacity. Rated output: 7.0kw.
Rated speed: 2000r/min
Electromagnetic braking: without Mitsubishi mr-ccn1 oil seal: attached (Note 1,
note 2, note 3). Power supply: 200V.
Note 1 It can be supported by hg-kr and hg-mr series above 0.1kw and hg-sr
series. Note 2 With reducer, oil seal is not equipped.
Note 3 The boundary dimension standards of hg-kr and hg-mr series servo motors
with oil seal are different. Realize the stable driving of medium capacity and
medium inertia products.
Through Jiahua structural design, Mitsubishi mr-ccn1 is realized. High speed &
high torque. Shorten positioning time and realize high-speed equipment. Reduce
power on torque ripple.
By combining the number of poles and slots of Jiahua motor, the power on torque
ripple is greatly reduced, and the smooth and constant speed operation of the
equipment is further realized.
To improve the environmental resistance, hg-sr and hg-jr series products adopt
IP67. Servo motor series: low inertia, medium and large capacity. Rated output:
9.0KW Mitsubishi relay connector kit. Rated speed; 3000r/min。 Electromagnetic
braking: without. Power supply: 200V.
Suitable for high frequency operation or high acceleration and deceleration
operation of medium, large capacity and low inertia products. To improve the
environmental resistance, hg-sr and hg-jr series products adopt IP67. High
speed & high torque. Shorten positioning time and realize high-speed equipment.
In 100 sites, there are 100 different drive controls. In order to meet
diversified and detailed site needs as much as possible,
In the configuration of mr-j4 product line, the main rich co service amplifier
and co service motor product Mitsubishi relay connector kit are provided, which
can meet the different needs of different customers. Servo motor series: medium
inertia, small capacity. Rated output: 0.85kw.
Rated speed: 1000r / min Mitsubishi relay connector kit. Electromagnetic
braking: without. Power supply: 200V.
Realize the stable driving of medium capacity and medium inertia products.
Through optimized structural design, the small total length in the industry is
realized,
High speed & high torque, shorten positioning time, realize high-speed
equipment and reduce power on torque ripple.
By combining the number of poles and slots of Jiahua motor, the torque ripple
of power on is greatly reduced, and the smooth and constant speed operation of
the equipment mr-ccn1 is further realized.
To improve the environmental resistance, the series products of hg-sr and hg-jr
adopt IP67 Mitsubishi mr-ccn1. Length of line: 10M. IP grade: IP65. Direct
connection type.
The cable is unshielded. Bending life: standard.
Connector kit for motor electromagnetic brake.
Cable for electromagnetic brake: used for hf-kp / hf-mp series (led out from
the same side of motor shaft).
- Q: e.g. medical equipment
- Best thing to do is use a surge protector and if the equipment is costly enough use one voltage stabiliser/CVT/UPS in addition.
- Q: i have a situation with my computer i don't know what it is but i have done a lot of test so please help me identifying this and how to solve it My build: CPU: i7 5820k MOBO: x99 g1 gaming 5pPSU: seasonic m12 750wGFX: g1 gaming gtx 980 ti
- Using water pipes as temporary grounding solution is not bad. But. You or someone must solve the grounding issue in your house or apartment properly. The next time you have thunder storms or similar disturbances, your electrical equipments and electronics at home might be broken, one after another. You have quite a big problem there, do not under estimate it!.
- Q: I am a commercial real estate appraiser and I oftentimes need to be specific about the electrical service available within a building. I can read the service panel(s) and total the various amps volts, but I don't know what is relevant to report. For example, I recently inspected a very large industrial building and all of the service panels combined had a total of 30,000 amp, and I also noted that it had a 3-phase unit. Is that relevant to report that is was 30,000 amp, 3-phase service? Should I also report the voltage? Should it read: 30,000 amp/### volt 3-phase service. In the future, can I just read the service panel(s) and total the numbers? Just because a panel says 4000 amps, does that mean it actually has 4000, or that it can handle that many amps?I know that's allot of questions, but any help that I can get would be helpful. Thanks!
- I believe that the sum of the individual service panels can exceed the service capacity of the building just as the sum of the individual circuit breakers in a panel can exceed the capacity of the panel. It is allowable to assume that not every load will be using power at the same time. Near the meter, there should be a master circuit breaker or set of fuses that determine the ampere rating of the service to the building. In a large industrial facility, that location may accessible only to qualified personnel, and you may need to ask a qualified person to give you a description. You should state the voltage, number of phases and current or KVA available at the meter location. For a large facility, you may want to itemize the ratings of panels serving major spaces and/or verify that all major spaces have the same voltage and number of phases available. For large industrial facilities, you should also determine if the utility or the customer owns major outdoor electrical equipment that is on the property.
- Q: construction, agricultural, forestry, medical, electrical HVAC etcwhat it will be the best name for a business that it will supply some agency with all kind of equipment ( for all possible industries and activities)
- Industrial okorder
- Q: I cut a deal with my electrical shop teacher. If i tell him how we can relate an electrical class to ski lifts and snowmaking and learn about how they work and the electrical portion of them then hell take my shop to our local mountain Wachusett. Can anyone tell me how ski lifts and snowmaking equipment work and how i can relate it to electrical
- Most ski lifts drive their cables from an electric motor. (This provides efficient torque control and emergency shut-down capability.) Snow making equipment uses electric drives for the water pumps and air compressors. (They make snow by freezing a sprayed water mist with the expansion cooling of the compressed air.)
- Q: I want to run an appliance that uses DC 5V 2.5A at 6 watts consumption using an adapter from the cigarette lighter socket. I have a standard 12v car battery in the small car. Do i need to get a bigger battery/more batteries, special alternator, or something else to run this appliance permanently?Is there an online calculator to help me work out how much battery power i need?Many Thanks to all answerers.
- First, 5 V times 2.5A equals 12.5 W, not 6 W. I'll assume, therefore that 6 W is the average, but the peak may be 12.5W. Also, assuming no conversion losses by the adapter, 12.5W in 12.5W out. Since the socket delivers 12 V, you're looking at about 1A peak. To a second approximation, divide by the adapter's efficiency (I'd guess 85%) to find out what's drawn - might be just shy of 15W. Most sockets have a current or power rating. My car says 120W, 12V - which translates to 10A. If you can't find the rating, check the fuse rating. It's probably 10 or 15A. If your car socket has the same rating as mine, you could run 8-10 of your appliances with no problem, all at peak, and 20 of them on average.
- Q: for example, a 3ds?
- Never heard of 3ds? DVDs - dish soap water. Dry with clean cotton towel. Does not work? Buy a new one.
- Q: I need some opinions on why do we recycle, computers, tv, cellphones, etc.I know it saves the environment because if we throw it away, it would just end up in landfills but is there anymore reasons?
- They are made from a number of valuable materials. Gold, for one. Its used on connectors as it doesn't tarnish or corrode, making the connection reliable. They also use a number of poisonous heavy metals. Letting used computers go into the garbage dump allows those metals to leach out and possibly pollute the water supply. Recycling keeps down that pollution by reusing those metals.
Send your message to us
Without Holding Brake Plug Set MR-CCN1 Motor Part For Servo Amplifier
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 100 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches