Wafer Type Check Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 40 Tons Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery of Wafer Type Check Valve
Packaging Details: wooden case applicable for shipping
Delivery Detail: 30days
Specifications of Wafer Type Check Valve
valve type: wafer, nominail pressure: 1.0/1.6MPa, DN50-DN400, certificate: ISO9000, ISO40001, CE, API, EN1074
series: Dual plate check valve
1) Size: DN40-DN400
2) standard: API594 ANSI 16.34
3) pressure standard: API598
4) face to face: ISO5752, DIN3202
5) body: cast iron/ductile iron/WCB
6) Seal ring: NBR/EPDM
7) Shaft: Carbon Steel/stainless steel
8) suitable temperature:-15~150
- Q:What kind of check valve is used in the sewage pump of sewage treatment plant?
- Selection of check valve for pump outlet check valveGeneral pump station project, for the pump outlet check valve, the following principles should be observed;The outlet check valve shall be used when the diameter of the outlet pipe of the pump is smaller, that is, DN50mmThe pipeline of the pump outlet pipe diameter DN is larger than 50mm, should be used in swing check valves can be installed horizontally or vertically. Swing check valve to rotate around the shaft, the fluid resistance is generally less than the lift check valve, which applies to the larger diameter of the occasion, the installation location restrictions, usually installed in horizontal pipelines, it applies with large caliber occasions. According to the number of valves can be divided into single swing type, double valve swing and multi valve swing type of three. Single swing check valves for medium and medium duty applications. Large diameter pipeline using single swing check valve, in order to reduce the water hammer pressure, it is best to use water hammer to reduce the pressure of the slow closing check valve. Double valve swing check valves are suitable for large and medium diameter pipelines. Double check swing check valve with small structure and light weight is a fast check valve. Multi disc swing check valve is suitable for large diameter pipeline
- Q:What does the H/F/P stand for in the check valve H41H/H41F/H41P?
- The first H represents the check valve, the 4 represents the flange, and the 1 represents the lift type, and the second H represents the seat seal surface. The material is alloy steel or stainless steel. The P H41P said seating for boron steel
- Q:I installed here in the water pump inlet, water pump with a 100 tons of water tank, there are many pumps, long time running, the pump will heat the cylinder, there is no water in the cylinder, the pressure does not go. The water pump is imported. Is the check valve broken or is the installation position wrong?
- Check valves are installed at the outlet of the pump. The reasons are as follows:The function of the check valve in the water supply system of the water pump is to prevent the impact of the high pressure water on the impeller of the pump. System in operation, for some reason, when the water pump suddenly stops running, the pressure inside the pump disappears, and the high-pressure water connected with the water pump outlet will reverse flow backwater pump. When the pump outlet is equipped with a check valve, it will be closed immediately to prevent the high pressure water reverse flow backwater pump. Prevent water pump reverse and so on.Check valve refers to rely on the flow of the media itself and automatically open and close the valve flap, used to prevent the media back flow valve, also known as check valve, Dan Xiangfa, counter flow valve and back pressure valve. The check valve belongs to an automatic valve, whose main function is to prevent the backflow of medium, prevent the reverse of pump and drive motor, and release the container medium. The check valve can also be used to provide a supply to the auxiliary system where the pressure may rise above the system pressure. The check valve can be mainly divided into swing check valve (rotating by gravity center) and lift check valve (moving along the axis). The function of this type of valve is to allow the medium to flow in one direction and to prevent flow in the opposite direction. Usually the valve is automatically work, fluid pressure flow in one direction, the valve open; the opposite direction of fluid flow by gravity, fluid pressure and valve closing effect on the valve seat, thereby cutting off flow.
- Q:Which side of the gate is the fire check valve in the pump room?
- The check valve is installed between the shock absorbing flexible joint and the water outlet control valve at one side of the water outlet pipe of the water pump
- Q:Check valve does not automatically check back, how to adjust?
- 4 the vertical lift check valve shall be mounted on a vertical pipe.5, the lift type horizontal check valve shall be installed on the horizontal pipe.6. Do not check the weight of the valve in the line. The large check valve shall be independently supported so as not to be affected by the pressure caused by the piping system.
- Q:We are high-rise buildings, with the smart recharge meters, before always someone to reflect the water used soon, 27 tons of water in only a month has gone. Later I heard that the water meter in front of a check valve on it, but when the five tons of water after the use of nothing, and nothing. Why does that happen? Does the check valve stop the water meter from idling?There is a special case, thirty storey building, booster pump has a pressure in the debugging of the fifteenth layer of what, every time on the twentieth floor of the owners reflect his home water intermittent, sometimes when a shower suddenly no water, we always to reflect the property many times, we are the plumber debugging a few times, or not. Later said that can not be adjusted, and then the tune will burst, and this is how it happened? How can I solve this problem? Why didn't the owners of the thirty and fifteen floors reflect the shortage of water pressure? But the owners of the more than 20 floors are so unlucky?
- 4. conclusionMany reasons for water rotation, but on the whole can be divided into two: one is the subjective factors, namely subjective causes, such as construction acceptance, human responsibility caused by Water Leakage, original gas gathering, which can strengthen the construction management, improve the staff's work and to improve the level of responsibility. The two is the objective factors, the main characteristics of the water itself, by the characteristics of pipeline and the level of technology development in the external objective factors, on the one hand to work in the future continue to explore the improvement will be improved.
- Q:Is the check valve the same?
- Same。 Call a difference; a thing. You come to our store to have a look.
- Q:PPR check valve, butterfly valve, as well as water gauge which quota?
- The valves and water meters installed in the same pipe are the same
- Q:Why should the check pipe be added to the chilled water pipe of the air conditioning unit?
- The air conditioning water chiller is usually installed in the basementNo check valve, pump start pressureThe current is likely to boil the pump when the building is high
- Q:Back pressure valve and check valve difference
- Oil is generally put into the wells of the check valve calling back pressure valveCheck valve is a general name, mainly lifting type and swing type.
1. Manufacturer Overview |
|
---|---|
Location | Jiangsu,China |
Year Established | 2001 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | English |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | High and/or Average |
Send your message to us
Wafer Type Check Valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 40 Tons Per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords