• BFEA Cheap Check Valve System 1
  • BFEA Cheap Check Valve System 2
  • BFEA Cheap Check Valve System 3
BFEA Cheap Check Valve

BFEA Cheap Check Valve

Ref Price:
get latest price
Loading Port:
Beijing Port
Payment Terms:
TT or L/C
Min Order Qty:
20 sets pc
Supply Capability:
To Order pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Check Valves

Check Valves are used in pipes under pressure between Class 150~2500LB, working temperatures﹣196~600℃. They are used in industries including oil, chemistry, pharmaceutical, fertilizer, and power gene-ration to prevent the backward flux of the media.

Design Feature of Check Valve

1. The products feature a reasonable structure, reliable seal, good performance and nice modeling. 2. Either soft or hard seal can be selected for the product upon different working conditions. The sealing face is built up with Co-based carbide alloy, leaving a better wearability, corrosion and scrap resistance and a longer duration.

 

3. Small opening pressure, the disc can be opened fully with a very small pressure differential.

 

4. Inside-set bolt-bearing structure reduces leakage and reliable use.

 

5. Class≥1500LB, the middle cavity uses a self-tightening sealing structure to have the sealing performance reinforced along with the pressure rise so as to ensure the sealing performance.

 

6. Different parts materials and different sizes for flange, butt-welding are available for sensible combination according to different working facts and customers' requirement

 

 

Technical Data of Check Valve

SizeDN40-DN600
Face to FaceDIN 3202 F6
Flange DrillingEN 1092-2 PN16
Inspection and TestISO 5208

 

﹡For all available general design, face to face standard and flange drilling,please kindly contact CNBM directly.

 

Materials of Parts

PartsDescriptionMaterial
1BodyGG25
2Seat RingBrass
3Disc RingBrass/EPDM
4DiscGG25
5HangerGGG50
6Hanger PinStainless Steel
8Cover GasketGraphite with Soft steel
9CoverGG25

 

Dimensions of check valve

Size(DN)LDD1D2bn-dHW.T(kg)
4018015011084184-191109
5020016512599204-1913013.4
65240185145118204-1914017.7
80260200160132228-1915020.8
100300220180156248-1916029.3
125350250210184268-1919047
150400285240211268-2321067
2005003402952663012-23250118.7
2506004053553193212-28310171.9
3007004604103703212-28340232.5
3508005204704293616-28450330
4009005805254803816-31520460
4501006405855484020-31550580
50011007156506094220-34590700
60013008407707204820-37680780

 

The producing department of Check Valve

 

check valve

 

check valve

The package of Check Valve

Check Valve

 

Q:What is the structure of the check valve of the screw air compressor?
Work process: air pre filter, and then through the air filter and the air inlet controller into the mixing chamber and the compression screw lubricating oil, continuous linear by asymmetric rotor two, compression. The compressed oil and gas mixture enters the tank and the separation system for three levels of separation (centrifugal, self weight, and fine separation). The separated compressed air is discharged after the cooler is cooled, and a reliable pressure switch system controls the exhaust pressure. When the machine is running, the screw compressor run oil system by pressure difference automatic circulation, without pump. When starting, the minimum pressure valve is closed to ensure the minimum pressure required for the lubrication oil circulation. In addition to lubrication, the oil also acts as sealing, cooling and reducing noise. High efficiency oil and gas separator and high efficiency cooler ensure high quality compressed air.
Q:Above the flue that valve is called smoke exhaust valve or check valve, I heard there is a five anti exhaust valve
The names are different, and they are acceptable. Five, anti exhaust valve is unique to 10000, the first class of technical effects
Q:What happens when the check valve is broken?
Check valve is broken, there will be back water, down pressure, serious will produce pump reversal, burning motor
Q:I have to use a check valve to prevent return water due to pipe installation problems due to regular water supply. But the recent discovery of a running water phenomenon, just on a full tank of water slowly from the pipeline flow away, but not all go, a flow did not flow, time is not the same, but sometimes sometimes does not flow, this is going on, ask professional personage answer
You should be horizontal check valve, with pressure difference, water pressure is not lost; or a check valve inside where the card, must be a certain pressure to baffle back.
Q:What's the difference between the check valve and the stop valve?
Check valve is also called check valve or one-way valve, single-phase closed, individual hydraulic control one-way valve, plug valve also has a combination of controllable changes.The cut-off valve has the possibility of variable flow, two-way action, throttling possible, there can be two-way closed applications.
Q:We are high-rise buildings, with the smart recharge meters, before always someone to reflect the water used soon, 27 tons of water in only a month has gone. Later I heard that the water meter in front of a check valve on it, but when the five tons of water after the use of nothing, and nothing. Why does that happen? Does the check valve stop the water meter from idling?There is a special case, thirty storey building, booster pump has a pressure in the debugging of the fifteenth layer of what, every time on the twentieth floor of the owners reflect his home water intermittent, sometimes when a shower suddenly no water, we always to reflect the property many times, we are the plumber debugging a few times, or not. Later said that can not be adjusted, and then the tune will burst, and this is how it happened? How can I solve this problem? Why didn't the owners of the thirty and fifteen floors reflect the shortage of water pressure? But the owners of the more than 20 floors are so unlucky?
2.3 installation methods and installation quality2.3.1 since the water meter is now out of the door, most of the units are all concentrated in one box and installed on the first floor. Taking into account the freezing cold winter and the meter, with 6 or 12 meter with a diameter of 40mm- 50mm diameter pipe, tables and small spacing and straight sections set aside less water, this will also affect the normal water metering, causing water rotation.2.3.2 installation quality, pipeline projects are basically buried in the ground or in the wall, is a hidden project. National construction standard pipe provides various pipe pipeline construction installation requirements, construction process, acceptance criteria and matters needing attention, but in the construction site, some managers do not according to the requirements of the code construction, more or less there are some quality problems caused by pipeline.
Q:How does the check valve work?
Only one-way flow, blocking the valve seal, liquid can not be returned.
Q:Our unit pump outlet check valve installed in the vertical pipe, the use of the valve to stop the valve is more serious impact, is not installed, the valve should be how to install it?
Installation method of pump outlet check valve:1, swing check valve is generally installed in the horizontal pipe: for caliber DN~80mm check valve, can also be installed in theVertical or upward sloping pipe.2, the straight through lift check valve should be installed on the horizontal pipe;3, vertical lift check valve must be installed on the vertical pipe, the medium for bottom-up flow.As the check valve is easy to damage, therefore, should be installed near the pump outlet valve, in the upper part of the check valve with a cut-off valve (general use of ball valve or gate valve), easy to overhaul. To facilitate the relief of the check valve before disassembly, the relief valve shall be installed between the check valve and the shut-off valve.
Q:What is the HC41X-16Q model of the optical valve? What is its main function?
The HC41X-16Q check valve for the light valve is a flanged silent check valve.HC41X-16Q flanged check valve features:An acoustic check valve whose structural characteristics allow only medium to flow in one direction and prevent flow in the direction.
Q:How to install the check valve?
Mounting position of check valve:Installed in the cut-off valve (solenoid valve, pneumatic valve, etc.), to prevent the back of the valve medium, the formation of back pressure or water hammer, affecting the normal use of the front valve.Check valve installed in the pipe bend elbow or vertical direction of the drop is larger, but also to prevent water hammer impact on the pipeline and damage.
We are one of the largest enterprises in China, integrating research, development, production, marketing and commercial services of stationery.And it became the largest manufacture of the writing instruments in Asia, with the scale of production ranked the first in the consecutive 12 years in China, and the sales ranked the third in the global industy, and the strength ranked within the eighth.

1. Manufacturer Overview

Location Beijing,China
Year Established 1986
Annual Output Value Above US$100 Million
Main Markets Africa, Asia, America, Europe, Middle East, West Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Beijing
Export Percentage 41% - 50%
No.of Employees in Trade Department 498 People
Language Spoken: English,Chinese
b)Factory Information  
Factory Size: 42000 square meters
No. of Production Lines Above 20
Contract Manufacturing OEM Service Offered;Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords