• Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World System 1
  • Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World System 2
  • Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World System 3
Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World

Valve with Competitive Price from Valve Manufacturer on Hot Sale in the World

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
10000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

1.Structure of Gate Valve Description

A gate valve, also known as a sluice valve, is a valve that opens by lifting a round or rectangular gate/wedge out of the path of the fluid. The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. For extremely thick fluids, a specialty valve often known as a knife valve is used to cut through the liquid. On opening the gate valve, the flow path is enlarged in a highly nonlinear manner with respect to percent of opening. This means that flow rate does not change evenly with stem travel. Also, a partially open gate disk tends to vibrate from the fluid flow. Most of the flow change occurs near shutoff with a relatively high fluid velocity causing disk and seat wear and eventual leakage if used to regulate flow. Typical gate valves are designed to be fully opened or closed.When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low friction loss.

 2. Main Features of the Gate Valve

• Valve body cavity using non-toxic epoxy resin,both inside and outside flashboard completely is coated with rubber

•  Free of water pollution

• High manufacturing accuracy

• High strength

• Environmental protection and energy saving

• Good visual effect

3. Images

 

Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World

Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World

4. Gate valve Specification

 Valve with Competitive Price from Valve Manufacturer  on Hot Sale in the World

5.FAQ

1. What's are the characteristics of gate valve?

The distinct feature of a gate valve is the sealing surfaces between the gate and seats are planar, so gate valves are often used when a straight-line flow of fluid and minimum restriction is desired. The gate faces can form a wedge shape or they can be parallel. 

2. What is the work principle of gate valve

 The gate faces can form a wedge shape or they can be parallel. Gate valves are primarily used to permit or prevent the flow of liquids, but typical gate valves shouldn't be used for regulating flow, unless they are specifically designed for that purpose. Because of their ability to cut through liquids, gate valves are often used in the petroleum industry. 

3.  What is the structure?

Bonnets provide leakproof closure for the valve body. Gate valves may have a screw-in, union, or bolted bonnet. Screw-in bonnet is the simplest, offering a durable, pressure-tight seal. Union bonnet is suitable for applications requiring frequent inspection and cleaning. It also gives the body added strength. Bolted bonnet is used for larger valves and higher pressure applications.

 

Q: Standard and specification for pressure test of valves
Welcome to Beijing Shan'er pipeline control components Co. Ltd. consulting
Q: Remove the handle and lever the stem rotation with a wrench,
1, carbon steel (WCA, WCB, WCC) applies to working temperature between -29 ~ 425 degrees between the middle and high pressure valve. Used for superheated steam. High temperature and low temperature oil, liquefied gas, compressed air, water, natural gas and other media.2 、 low temperature carbon steel (LCB) is suitable for working temperature between -46 ~ 345 Degrees of low temperature valve.3, alloy steel WC6, WC9 is suitable for the working temperature -29 to 595 degrees between the non corrosive medium high temperature and high pressure C5, C12, C12A for working temperature -29 to 650 degrees between the corrosive medium high temperature and high pressure valve.4 austenitic stainless steel for working temperature between -196 ~ 600 degrees corrosion of any medium valve.5,
Q: Valve category can fill the trunk door, branch valve Mody?
Valve category refers to the type of valve, the big species are divided into: butterfly valve, gate valve, globe valve, ball valve, check valve, control valve, trap and electric valve,
Q: What is the difference between the adjustable range of valve 50:1 and 100:1?
Adjustable ratio is also called adjustable range, if to R to indicate, then R=Qmax/Qmin should pay attention to the minimum flow, Qmin and leakage of different meanings. The minimum flow refers to the lower limit of adjustable value, it is generally the maximum flow rate of Qmax 2%~4%, and the leakage is fully closed when the leak valve, it is only the maximum flow rate of 0.1%~0.01%.Adjustable range 100:1 generally can not reach, the accuracy of this valve is very high.
Q: Hydrant valve leaks, how do you close other valves? Specific steps?
In construction, according to the design specifications, fire hydrant water supply pipe is an independent water supply system, and the water supply pipeline is separated from the water supply. In the trench into door position, need to set up a system of fire fire well, there are valves, only by finding the position of tube wells into households completed fire system diagram, in turn off the total valve can.
Q: The general signal valve installation, or other valve installation is not installed with the groove flange clamp hoop Yucca or direct way? What's the convenient way to install the following diagram? I don't understand. Neither groove, flange nor hoop. Thank you, sir!
The installation of the signal valve is in accordance with GB50261-2005The 5.4.6 signal valve shall be installed on the pipe in front of the flow indicator, and shall not be less than 300mm from the flow indicator.The other valve control valve installation, specification, type and location of installation shall comply with the design requirements, the installation direction should be correct, control valve should be clean, no blockage, no leakage; the main control valve should be added headstock logo, the control valve cover shall be provided to indicate position of the mark in the position.1. The installation of the exhaust valve shall be carried out after the pressure test and the flushing of the system pipe. The exhaust valve shall be installed at the top of the water distribution dry pipe and the end of the distribution pipe, and no leakage shall be ensured.2, the valve flow direction should be consistent with the direction of flow in the water supply pipe, water inlet side of the filter is installed, and should be installed in the control valve; the adjustable valve should be installed horizontally, the valve cover should be upward; the proportional valve should be installed vertically: when the level of installation, the valve orifice hole single breath we should double down, breathing valve whose orifice should be in a horizontal position.3 other control valve should be installed to keep a certain distance, to facilitate maintenance and management, installation of multifunctional pump control valve itself with pressure gauge, pressure gauge should be installed in the adjacent parts; import should be prevented in the back before the installation or use of the filter with filter backflow preventer, backflow preventer at both ends the valve should be installed separately, and at least one end of the flexible joint should be installed;
Q: What valve is the VENT?
In order to reduce the leakage point, sometimes before the factory will be welded to death.DRAIN position must be in the lower position of the valve body, is generally able to reach the lowest point.
Q: What's the sewage treatment valve with?
Sewage treatment system valve requirements are not high, the use of butterfly valve is one of the most cost-effective. Butterfly valve manufacturers are many, the price is also different, as long as the right can.
Q: There is a rectangular hole in the valve core, which the heating company repairman gives to the bolt. Rest assured, I do not want to heating, but my indoor temperature is low, I suspect that the repairman mischief, deliberately give me lower temperature
The valve has a device resembling a cylinder lock without a dedicated key. However, your home heating is not hot, the valve does not have much relationship. As long as the hole on the valve is parallel to the pipe, the valve is fully open.
Q: What's the material of j41h-16p's valve?
Stop valve characteristics:(1) the structure is simpler than the gate valve, and the manufacture and maintenance are more convenient.(2) the sealing surface is not easy to wear and scrape, good sealing, when opening and closing, there is no relative sliding between the valve and the sealing surface of the valve body, so the abrasion and abrasion are not serious, the sealing performance is good, and the service life is long.(3) when opening and closing, the valve stroke is small, so the cut-off valve height is smaller than the gate valve, but the structure length is longer than the gate valve.(4) the opening and closing moment is big and the opening and closing are more strenuous.(5) large fluid resistance, due to the valve in the medium channel is tortuous, large fluid resistance, power consumption.(6) the flow direction of medium nominal pressure PN is less than or equal to 16MPa, commonly used downstream, medium from the valve under the direction of flow; nominal pressure PN = 20MPa, using reflux, medium from the valve on the downstream direction to increase the seal. When used, the cut-off valve medium can only flow in one direction, can not change the direction of flow.(7) when fully open, the disc is always subject to erosion.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords