Size: DN20-DN800
Nominal Pressure: PN10/PN16/PN25
Operation Temperature: ≤80°C
Suitable Medium: Water
2.Feature
400 x flow control valve consists of the main valve, flow regulating valve, needle valve, pilot valve, ball valve, micro shape filter and pressure gauge of hydraulic control of system. Use of hydraulic automatic operation, control and adjust the opening of the main valve, made by the main valve flow rate remains constant.
400 x flow control valve with hydraulic control on our own efforts, do not need other devices and energy, easy maintenance, stable flow control. 400 x flow control valve is widely used in water supply network system of high-rise buildings, residential and urban water supply engineering.
When the valve from the inlet water supply, water flows through a needle valve in the main valve control room, and after a pilot valve, ball valve, from the main valve control room to export, the main valve in the fully open or floating state. Setting the upper master valve flow control valve, can be set in a main valve opening. Adjust the opening of needle valve and regulating valve spring pressure, can keep the main valve opening in setting the opening, and pilot valve to automatically adjust when pressure changes, the flow rate unchanged.
- Q:How can the material be checked by valve approach? What experiments do you need?
- First of all, to check material certification, and secondly, the material appearance, shape and size of the initial test, again on the alloy material according to the standard spectrum analysis, the valve to do pressure test.
- Q:Valve pressure grade division
- Valves are classified by pressure:Vacuum valve - valve with operating pressure below standard atmospheric pressure.Low pressure valve - nominal pressure PN is less than 1.6MPa valve.Medium pressure valve - nominal pressure PN 2.5~6.4MPa valve.High pressure valve - nominal pressure PN10.0~80.0MPa valve.Ultra high pressure valve - nominal pressure PN greater than 100MPa valve.
- Q:Where is the filling portion of the valve?
- Along the stem to find, stem into the valve can not see, invisible place, here is the filler. Popular bar!
- Q:Proportional valve why than other small pipeline valves
- 3.8 valveGraphical representation of numbers, names, symbols3.8.1 angle valve at room temperature3.8.2 cold angle valve for low temperature use3.8.3 stop valve at room temperature3.8.4 ball valve often 9 temperature3.8.5 valve at room temperature3.8.6 butterfly valve at room temperature3.8.7 check valve flow from blank triangle to non empty triangle3.8.8 pressure reducing valve, small triangle for high voltage end3.8.9 throttling valve is needle valve3.8.10 three-way valve for normal temperature use3.8.11 four way valve used at normal temperature3.8.12 safety valve spring type safety valve3.8.13 trap actual drawing, you do not have to draw arrows3.8.14 inflator, cold box, little gas huff and puff, safe useValve for normal temperature of regeneration valve of 3.8.15 reverse stop valve3.8.16 reverse loading cold angle valve
- Q:What is the purpose of the valve?
- 3. Change the direction of the medium flow in the pipeline. Such as the distribution of valves, three way cock, three or four ball valve etc..4, stop the medium back flow in the pipeline. A variety of different structures such as check valve, valve etc..5, separation medium. Such as different structures of steam traps, air traps and so on.
- Q:How can you replace the other valve when the main valve is not closed and no water is stopped?
- In general, a unit has a total valve. From this start, find it, find a less water when passing the total valve home to change, more energy, save trouble later. Or find the person of the company to deal with tap water.
- Q:What valve should be used to test the water valve?
- 3, ball valve (ball valve should be a cut-off valve in the marine and marine field), standard GB/T21465-2008 "valve terminology" is defined as: opening and closing parts (ball) driven by the stem, and around the valve axis for rotation of the valve. Can also be used to regulate and control fluid, strong shear force between the metal seat seal V type ball valve V type ball core and welding hard alloy, especially suitable for containing fibers, small solid particles and other media.
- Q:What does "DN15" mean? What does "PN 16" mean?
- Valve nominal diameter 15mm, valve nominal pressure 1.6MPa
- Q:What is the difference between valve j941H-40 and j41H-40?
- I see "valve design manual" category code table, in front of 9 of the electric drive, no 9 is the ordinary hand wheel drive.
- Q:What does "1/2" mean on the valve?
- 1/2 is 4 points (20), 3/4 is 6 points (25), and 1 is 1 inches (32)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Flow control valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords