• SVC Single Phase Power Regulator System 1
SVC Single Phase Power Regulator

SVC Single Phase Power Regulator

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
2000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Application

 

Widely used in the fields of post office,store,elevator,hospital,school,publishing house and stock exchange where normal voltage is in need,and also can be used in the factories of large and middle-scale industrial and mining corp,it is very much suitable for some important devices and supporting single machine.

 

Input voltage

Three-phase four-line system phase voltage:220±20%

 

line voltage:380±20%,or phase voltage:220±30%

line voltage:380±30%(can be selected.Please specify when ordering)

Single-phase:220±20% or 220±30%(can be selected.Please specify when ordering.)

 

Output voltage

Phase voltage:220V Single-phase:220V Line voltage:380V

Output voltage accuracy

1-5%(can be adjusted)Frequency:50HZ/60HZ

Efficiency

≥98%(Power grade over 50KVA)

Ambient temperature

-10~+40°C

Insulation resistance

≥5MΩ

Electric intensity

The voltage for electrical strength and power frequency sinusoidal is 2000V without breakdown and flash over when lasts 1minute

Overload Capacity

It can last 1 minute at the rated current of two times

Wave form Distortion

No additional waveform distortion

Protective function

it offers the protections against over voltage,over current,phase shortage and phase-sequence(The single-phase offers no protection against the phase shortage and phase-sequence)and mechanical failure

Response speed

≤1s(in the condition that the external voltage changes is 10%)

 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
Q: Who knows how big transformers and lines the 36V transformer uses in lighting?
The sectional area of the wire can be calculated according to the electric power formula. The current required by the wire is calculated, and then the reference to the national standard "500 volt copper core insulated wire, long term continuous load allowable ampacity meter" is selected.
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
Q: Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Q: Power and lighting transformers, lighting quality will be affected much?
The quality of transformer itself, coupling coefficient, overload capacity, as well as the impact current of the bulb, the cold resistance of the filament and the starting factor at the same time, it is better to choose the 400VA transformer.
Q: Why can't autotransformer be used as transformer for safety lighting?
The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b) Factory Information
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords