Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Application

 

Widely used in the fields of post office,store,elevator,hospital,school,publishing house and stock exchange where normal voltage is in need,and also can be used in the factories of large and middle-scale industrial and mining corp,it is very much suitable for some important devices and supporting single machine.

 

Input voltage

Three-phase four-line system phase voltage:220±20%

 

line voltage:380±20%,or phase voltage:220±30%

line voltage:380±30%(can be selected.Please specify when ordering)

Single-phase:220±20% or 220±30%(can be selected.Please specify when ordering.)

 

Output voltage

Phase voltage:220V Single-phase:220V Line voltage:380V

Output voltage accuracy

1-5%(can be adjusted)Frequency:50HZ/60HZ

Efficiency

≥98%(Power grade over 50KVA)

Ambient temperature

-10~+40°C

Insulation resistance

≥5MΩ

Electric intensity

The voltage for electrical strength and power frequency sinusoidal is 2000V without breakdown and flash over when lasts 1minute

Overload Capacity

It can last 1 minute at the rated current of two times

Wave form Distortion

No additional waveform distortion

Protective function

it offers the protections against over voltage,over current,phase shortage and phase-sequence(The single-phase offers no protection against the phase shortage and phase-sequence)and mechanical failure

Response speed

≤1s(in the condition that the external voltage changes is 10%)

 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
Of course, if you want to bring more is not impossible, but depends on the working conditions, the actual power = nominal power, short time use (to ensure that the transformer temperature rise is not too high) is also available
Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
The key is that the 220V terminals and 0 can not provide 1000VA capacity?
Q: Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Q: The difference between lighting transformers and control transformers
The lighting voltage is 36 and 12V, the signal lamp is 6V, the control winding is 127, 110V, the one or two insulation, and the two one is grounded.Simple lighting transformers, the two voltage is not so diverse.
Q: Why is elevator lighting transformer installed?
Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
Line lighting transformer is suitable for AC circuit of 50~60 (Hz). It is widely used in electronic industry or industrial and mining enterprises, mechanical equipment, general circuit control power supply, safety lighting and indicator light power supply.
Q: Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
Q: What's the function of the lighting transformer?
In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
Q: How to calculate the rated capacity of small transformers for lighting purposes?
If the flow of large capacity motor starting current and welding machine, large current flows in a short period of time in the load even when the power equipment capacity can withstand current flow in a short time, but due to a voltage drop excitation electromagnetic switch relief, the motor can not start, damaged or the undesirable phenomenon of welding. Therefore, the voltage drop rate should be calculated as less than 10% of the supply voltage, as calculated below.
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b) Factory Information
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords