Submersible sewage water pump V2200BF-4S
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
◊APPLICATION
Applied to pumping such liquid which is not clean, with solid matter or frictional matter, low viscous, lcorrosive, crystallizable, chemically neutral and close to water. Such as:
1. domestic wastewater treatment system
2. School,hospital,community wastewater treatment system
3. Irrigation
◊ Features
1. 100% copper wire
2. Cold-rolled silicon steel sheet, with high-speed punching, improve the efficiency and precision
3. Double sides mechanical seal graphite&ceramic
4. Demagnetization of stainless steel nuts
5. Anti-rust treatment castings and electrophoresis
6. New testing equipment
◊ OPERATION CONDITION
1.Maximum depth below water: 5m
2.Maximum trans medium temperature up to: 40
3.PH of trans medium is scope from 4-10
◊TECHNICAL DATA
description material | |
motor housing | stainless steel |
pump body | cast iron |
impeller | cast iron |
shaft | AISI420(2GR13) |
stator | DR510 steel |
winding | 100%copper |
seal | mechanical seal graphite&ceramic |
- Q: You'd better point out the details.... There are 2 best ways of experience and formulaCan you say a simple point, such as multi-stage pump, when the pump is higher than the motor, 30 wire is the next mouth how to do?
- Looking forAlignment means the position of the center of rotation of the pump and motor so that they are in the same line.At least three times after the initial installation or after installation:
- Q: What are the causes of pump shock?
- 6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
- Q: What should I pay attention to when buying a pump?
- There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
- Q: There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, two outdoor pumps, three units, one master and one spare control cabinet. From the control room to the control cabinet, is there only 3 lines or 9 lines?... How do I get it? Where does the hydrant line come from?
- Spray pump in addition to remote direct Kai, there are modules to start function, that is, on the cabinet to add control module, bus linkage pump, in addition to the pressure switch, directly pumping function, a total of three functions.
- Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
- When the vacuum pressure is called vaporization pressure, cavitation is more than the surplus energy of vaporization pressure at the unit weight of the liquid in the pump suction port of the unit, with mark. The absorption process is to NPSH delta H: pump suction fluid allows the vacuum pump installation height is the unit of rice.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
- Q: What are the parts of a pump? How do you classify it?I just want to know
- Before opening the pump suction pipes and pumps must be filled with water. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet. The outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuous outflow from the discharge pipe.Mainly by the impeller, pump shell, pump shaft, bearings and packing sealing devices and other components
- Q: When the water pump is started, why should it start when the outlet valve is closed? Thank you
- And the pump at the start, if the valve opening pump, then the pump outlet pressure (head) is very small, so the pump flow will be great, the pump power is very large, causing the start-up current is very large. In addition, the starting current of the motor itself is also very large. These two factors add up to the possibility of overloading the motor, resulting in failure to start or even burn the motor.
- Q: What is the difference between an air pump and a water pump?
- Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
- Q: Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
- The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area
Send your message to us
Submersible sewage water pump V2200BF-4S
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches