Stainless Steel Tie
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 10000 Bags per Day pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Features:
Unique multi-locking mechanism design on the ladder strip can be applied without crimping tools. Self-locking for fast, easy application.Extended ladder slot provides larger bundle diameter with the same length of tie.Large round slot at the tail-end allows application of hook-type tools.Uncoated tie for high temperature applications. Coated surface provides excellent
chemical and weathering resistance, and superior insulation and protection of cables.
2.Size:
Width:6.3mm and 9.5mm
Length:from 100mm to 1500 mm.
3.Packing:
100pc per polybag,carton for outer packing.
- Q: The role of cable connector box classification installation requirements
- Should be the power cable and weak cable directly on the side, the middle partition separated. Standard: JB / T-2000 Standard Name: Electric Control Power Distribution Cable Tray Standard Status: Current Implementation Date: 2000-12-1 Issuing Department: National Electrical Appliances Accessories Standard Committee Content: This standard provides for electric control distribution The definition of cable bridge, model code, requirements, test methods, inspection rules, signs, transport and storage. Source:
- Q: Wire diameter of 15MM current transformer model for the BH-0.66- / 5LMK-0.66SDH-0.66 wear the core is very urgent online Thank you more
- When there is a large current through the wire will produce a magnetic field, a little bit of sound.
- Q: We bought the elevator dedicated cable, with video power wire, the customers say that they have done before the tie tie is not broken, is the elevator installation problem or they require bundled copper wire should not be used To tie There are several elevators that are now under the copper wire cut off more
- With a multimeter (or shake the table) to measure the insulation, not more than 0.5M Europe on nothing, as long as the insulation of the wire enough, PVC pipe is not used to waterproof, it is used to prevent mechanical trauma, even if not irrigation, buried A long time the tube also has water vapor, is inevitable, nothing!
- Q: How about the vertical installation of the bridge, cable, What fixed? It is best to look at the fixed pieces of pictures, thank you more
- Fixed, with a cable tie on the bridge, and soon fixed it? Remember that you can not use metal class can be tied
- Q: The elevator has 23 floors. But I have not installed before. I would like to ask how to install. How does the video line go? Thank you more
- You can find the staff responsible for the maintenance of the elevator with the shaft of the line with the cable can be wrapped together, but to have shielded wire.
- Q: Dual-value capacitor asynchronous motor starting up the speed is high and low What is the reason, the motor rotation just to the high speed suddenly down again more
- Since it is a discrete graphics, it is recommended to change the motherboard . although the price is almost, but 870 is usually a large board, suitable for wiring, and then graphics from the CPU to be far, so more stable. Graphics currently 5770 the most cost-effective.
- Q: How to connect the high voltage distribution cabinet twice
- If the trunking is made in advance, the cross-section at both ends is made as a standard 45-degree slope. When you need multiple trunks, you need to cut the slopes. The other turn some turn left, and sometimes need to turn right, how to know the direction of the slope in advance?
- Q: What equipment does fiber engineering need? What are the brands?
- Do outdoor fiber engineering. Sure to have steel wire, cable hook. Tighten the wire. There are escalators. But also more than 6M bamboo ladder. Because the strand to be linked to the 6M high position can be. Into the room, it is very simple. Pigtails, fiber jumpers, fiber patch panels. Couplers and so on. And then spread out the fiber from the inside of the cabinet after the patch panel. Then fused. After a good tie with a good tie. It is best to use optical power meter test under the barrier. Whether the attenuation meets the standard.
- Q: What are the precautions for using the cable mesh and how to use it?
- No instructions are clearly stated or allowed. In the "Code for Design of Electric Power Cables" (GB-2007), the provisions of 5.1.3 stipulate that if the number of cables in the same channel is large, if the laying of the multi-layer bracket on the same side, the following provisions shall be met: High to low power cables, strong to weak control and signal cables, communication cables "top to bottom" in the order. When the horizontal channel contains more than 35kV high-voltage cable, or to meet the introduction of the cabinet tray to meet the requirements of the bend radius requirements, should be "bottom-up" in order. In the same project or the cable channel extends to different projects, should be arranged in the same order. 2 bracket space by the channel space constraints, 35kV and below the adjacent voltage level power cables can be arranged in the same layer of support, 1kV and below the power cable can also be with the strong control and signal cable configuration in the same layer of the bracket. 3 The work of the same important circuit and the backup cable should be arranged on the different layers of the brackets. It is possible to note that it is restricted by passage space from section 2. If you really want to lay together, it should be noted that 10kV cable can not use single-core cable, you need to use three-core cable.
- Q: Communication equipment and telephone routine maintenance inspection need to pay attention to what
- Prepare a small air compressor, with air guns to remove the debris and water in the tube.
1. Manufacturer Overview
Location | Zhejiang, China |
Year Established | 2009 |
Annual Output Value | Below US$1 Million |
Main Markets | North America South America Eastern Europe Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO 9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | ningbo,shanghai |
Export Percentage | 81% - 90% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
Stainless Steel Tie
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 10000 Bags per Day pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords