Residual Current Circuit Breaker With Over Current Protection
- Loading Port:
- Wenzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 10000pcs pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
You Might Also Like
Application |
DZ47L C45L RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 1 phase 230V and 3 phase 400V, rated current up to 63A. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the RCBO can cut off the power within the time of 0.1s automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current. With this function, the RCBO can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009 standard. |
Normal Operation and Mounting Requirement |
◆Circumstance temperature -5~+40, average temperature not exceeding 35. ◆Altitude above sea level less than 2000m. ◆Humidity not exceeding 50% at 40 and not exceeding 90% at 25. ◆Installation class II or III. ◆Pollution class II. ◆Installation method DIN Rail mounting type. ◆The external magnetism shall not be more than 5 times of terrestrial one. ◆Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position. |
- Q: Frame circuit breaker, molded case circuit breaker difference
- and they usually buy some of the experience to sum up, here that under the molded case circuit breaker and Frame circuit breaker difference between the two,
- Q: Household leakage circuit breakers, circuit problems
- The The 2. There are two holes at the top (one write N and the other without writing), and the bottom has two holes (one write N and the other). Above
- Q: How is the total switch breaker in the distribution box correctly
- such as leakage or physical impact is achieved through the sensing element to its leakage or electric shock leakage
- Q: What is the solution of the leakage circuit breaker always jumping?
- Do not let the lighting lines and socket lines mixed, so that the socket circuit leakage switch will open the leakage protection switch to trip .
- Q: Low-voltage circuit breaker is what can be broken and under normal conditions of the circuit
- led and so can not light The Is the base high level, N tube is generally off, low level, N tube open
- Q: Which is the circuit switch, that is the circuit breaker
- so the frame circuit breaker and molded case circuit breaker applications are different occasions, the framework used in the higher into the line, molded case applied to the lower level of the framework.
- Q: Discussion on the Selection of Circuit Breaker in Low Voltage Circuit
- and the frame circuit breaker rated current is much larger, generally 630A-6300A (such as our company's DW15, DW16 and DW17 series
- Q: Why the first break circuit breaker, after the isolation switch off it?
- can not disconnect the charged circuit, so the disconnector should be used in conjunction with the circuit breaker.
- Q: The difference between the leakage switch of the air switch circuit breaker
- Anyway at home is also boring I will seriously come back to your question hope to help you
- Q: Is there a sequence of circuit breakers and disconnectors?
- and there is no problem. After the circuit breaker, the circuit breaker has the ability of interrupting,
Send your message to us
Residual Current Circuit Breaker With Over Current Protection
- Loading Port:
- Wenzhou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 10000pcs pc/month
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords