Raw Materials for Refractory Graphite Steel Ladle Slide Gate Plate
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 500 m.t.
- Supply Capability:
- 10000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
1.ISO9001:2008
2.Types:Al-C,Al-Zr-C
3.Average life: 6times
4.High strength,good corrosion and thermal shock resistance
Slide gate plate widely used in large ladle, middle ladle and small ladle to fit for high quality steel casting.
And including Alumina carbon and Alumina Zirconia Carbon slide gate plate, MgO and MgO-spinel slide gate plate,nonoxides bonding slide gate plateand unburned slide gate plate
ITEM | Al2O3-C slide gate | Al-Zr-C slide gate | Magnesia slide gate | |||
LTH-68 | LTH-72 | LTH-78 | LTH-85 | |||
Al2O3 ,% ≥ | 68 | 72 | 78 | 85 | 72 | 8 |
ZrO2 ,% ≥ | 6 | MgO≥80 | ||||
C ,% ≥ | 7 | 7 | 7 | 5 | 7 | |
Apparent Porosity ≤ | 8 | 8 | 10 | 10 | 8 | 10 |
Cold Crushing strength Mpa≥ | 80 | 90 | 100 | 120 | 120 | 50 |
Bulk Density g/cm3 ≥ | 2.70 | 2.80 | 2.90 | 3.00 | 3.00 | 2.95 |
HMOR(1400°C×0.5h) ≥ | 8 | 9 | 12 | 13 | 13 | 6 |
Features
1.good workability
2.good resistance to chemical attack
3.high bonding strength
4.low drying and firing shrinkages
5.good slag resistance, small masonry ash joints
- Q: Why the refractories should be waterproof and wetproof
- The binding agent of many raw materials is water-soluble. It will be useless when meeting water.
- Q: Who knows the fire rating of fire?partition with steel stud?
- 1 hour. It is in line with the fireproof test standards of national building materials . CaSo4.2H2O is molecular structural formula of gypsum which contains 20% water, crystal water and free water. When 10% water slowly evaporates on the flame surface, there is still 10% crystal water. Itself is grade A fire retardant material. It can reach up to four hours at most.
- Q: What's the fire endurance of hollow brick?
- For hollow brick wall, it should be noted that outside are 200-thick coal gangue hollow brick wall on interior wall. Besides, the fire endurance should comform to GB50067-97 Fireproof code for garage, repair garage, parking lot design. 3), All joints of brick walls and concrete wall column should reserve rebar tie. Masonry mortar in internal and external walls should be full. Wall masonry should be up to bottom of beam slab and filled tightly with 1:3 cement mortar.
- Q: how is the high-temperature flame-retardant fibre board?
- The market is mainly divided into three kind of fiber. Density fiberboard, medium density fiberboard, high density fiberboard. Density fiberboard: It is rolled timber sheet made of wood shaving material produced by timber or non timber fiber that is added with or without glue or auxiliary material. A density of less than 450 kg / cubic meter, the larger fiber particles, the internal structure is not homogeneous, relatively lack of strength, lighter weight. MDF: use wood fiber or other plant fiber as material, added with glue. A sheet pressed at high temperature and pressure. A density between 450-880 kg / cubic meter, fiber particles is moderate, well proportioned internal structure, greater strength, moderate weight. HDF: Use wood fiber or other plant fiber as material, added with glue. A sheet pressed at high temperature and pressure. Its density is about 880 kg / cubic meter, small fiber particles, well proportioned internal structure, greater strength, greater weight. there are also artificial boards such as chipboard and melamine board in the market, generally used for making furnitures. the thickness of fiberboard that is produced and controlled more flexibly, is generally 5 per cent (general bulk price of 30 yuan per square meter), 9 cm (50 yuan), 18 cm (100), 25 cm (120), etc. There are thicker. However, proper deviation is acceptable. The board is usually thicker or thinner than the specified thickness. For example, It is only 16mm when specified 18mm.
- Q: I would like to ask a friend that how much is the fire endurance of level A fireproofing glass?
- the fire endurance of fire window is: class A window is not less than 1.2 hours, class B window is not less than 0.9 hours, Class C window is not less than 0.6 hour. technical requirements: 1, materials and accessories (1) the window frame is made by a certain strength of steel frame or wooden frame which is sufficient to safeguard the integrity and stability. (2) steel frame and mound layer can select galvanized?steel?sheet or stainless steel plate. Its selection standards should be in line with the provisions of Article 5.1. in GB12955 "Steel Fireproof Door General Technical Condition" (3) the selection standards of wood frame and mound layer should be consistent with the provisions of Article 5.1.1. in GB14101 "General Technical Conditions of Wooden Fireproof Door" (4 ) the inner filling material of steel and wood frame should be non-combustible material. (5) fireproofing glass can choose the qualified products in fire resistance test and not affecting the fire windows. light transmittance of glass is not less than 75% of identical layers of ordinary plate glass. ( 6) a sealing material between the frame and the fireproofing glass should use the nonflammable material, it can play the role of fireproofing and smoke insulation in the fire disaster. I hope I can help you
- Q: can slag tailings be used to be the base materials of refractory materials ?
- the rest of it can be used as refractory additives. the scale currently used clay bricks to make high-temperature liquid. It is easy to produce large amounts of liquid because of the high iron content, instead of its refractoriness. But it can be used as refractory minaralizer.
- Q: Firing high temperature kiln of refractory and internal temperature being as high as 1600 ℃, metal heat exchanger can't use, how to do?
- 1>3>。 When metal heat exchanger is in 700 ℃, it must process high temperature protection, mixed cold wind or cold blast to protect heat exchanger. So this will waste a lot of energy; The comparison of high temperature resistant ceramic heat exchanger using temperature is 1350 ℃ to 1450 ℃; metal heat exchanger using temperature 700 ℃; heat utilization comparison of ceramic heat exchanger can be placed in 1350 ℃ or higher (highest available to 1450 ℃); the oxidation resistance, a very short time will burn out;2 >, waste heat recovery rate is high. Replacing the metal heat exchanger in high temperature and corrosion environment; Comparative ceramic heat exchanger can be used under the condition of 1350 ℃ for a long time. Let's make a comparison, if it is a refractory material industry. <, ceramic heat exchanger is simply won't appear, under the condition of equal to ceramic heat exchanger using, energy saving effect is best, can exchange for the high temperature. <. Ceramic heat can be placed on the nearest of exchanger flue outlet . <, and metal heat exchanger put in place contrast to the ceramic heat exchanger. In the process of using metal heat exchanger, if this situation happens, you can consider the ceramic heat exchanger. Temperature difference is between 650 ℃ to 750 ℃. If the metal heat exchanger is placed in normal place where ceramic heat usually put;The service life comparison: since ceramic heat exchanger with high temperature resistance, this partly replace metal heat exchanger. What's more, energy-saving rate is also different. Metal heat exchanger can be placed in 700 ℃ or less;4 >, corrosion resistance, its application effect is very different. So the metal-heat-exchanger's heat-resistant temperature is high and the service life is the countless times of metal heat exchanger. The place with highest temperature does not need high temperature protection.
- Q: Are refractory materials and fireproofing materials the same?
- Refractories are generally used in the industry such as power plants, electric stove and industrial furnace. They include refractory bricks and insulation materials. Fireproof materials are generally used in building and they are fireproofing.
- Q: What is the limit of fireproof rolling shutter?
- Fireproof rolling shutter door is a kind of fire protection and heat insulation facility which is suitable for the large openings of buildings, having a certain effect on the design and installation. Fire shutter doors are widely used in fire partition of industrial and civil building. It can effectively prevent the spread of fire, to protect the safety of life and property. It is an indispensable modern building fire facilities. According to the national standard 14102-2005 GB standard, the provisions of 14102-2005 GB specify that: If fire resistance limit of fire resisting shutter is no less than 3 hours, it is AAA fireproof rolling shutter. Therefore, the fire resistance limit of AAA grade fireproof rolling shutter should be 3 hours.
- Q: What kinds of refractory materials that can resist 3,000 Celsius degree?
- I think that graphite is the only one.
Send your message to us
Raw Materials for Refractory Graphite Steel Ladle Slide Gate Plate
- Loading Port:
- Qingdao
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 500 m.t.
- Supply Capability:
- 10000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords