• Raw Materials for Silicon Wear-Resistant Magnesite Refractory System 1
Raw Materials for Silicon Wear-Resistant Magnesite Refractory

Raw Materials for Silicon Wear-Resistant Magnesite Refractory

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.High crushing strength
2.High hot strength
3.Good thermal shock resistance
4.Strong anti-stripping resistance

Characteristic:

  • High crushing strength

  • High hot strength

  • Good continuously forming protective layer during service

  • Good wear resistance,

Trademark

AZM-1 550

AZM-1650

AZM-1680

Item

Index

Index

Index

Chemical composition(%)

SiC+SiO2

≥35

≥30

≥32

Al2O3

≥60

≥65

≥65

Volume density(g/cm3)

≥2.55

≥2.65

≥2.70

Apparent porosity(%)

≤20

≤19

≤19

Cold crushing strength(Mpa)

≥80

≥90

≥100

Refractoriness under load(T0.6,°C)

≥1550

≥1650

≥1680

Thermal shock resistance,time(1100°C,water-cooling)

≥10

≥15

≥20

1) Good performance to thermal shock, corrosion, erosion and abrasion resistance.
2) High refractoriness and excellent mechanical strength.
3) Both intermittently and continuously working mode are acceptable, reducing lining cracks.
4) Longer and stable life cycle to reach high efficiency.
5) Suit for all kinds of metal types, reduce residue and porosity of the products.
6) Labor and cost saving by convenient installation and maintenance

Q:Would you like to know if there are any enterprises in Mianyang that need fire-resistant materials?
Big business needs to be usedIntroduce several big: Jiuzhou 208827 and Changhong
Q:What are the refractories for converter?
Analysis of refractories are as follows: MgO-C brick converter Dongxin refractory furnace cap, steel tapping hole, shaft, shaft, pool, air brick
Q:What are the differences between first-level fire-resistant materials and second-level fire-resistant materials?
Level B1: building materials with flame retardancy: this kinds of materials have good effect in flame retardation. Under the case of open fire or high temperature, it is not easy to be ignited and spread quickly, and when the fire source is removed, fire would stop immediately. Level B2: combustible building materials: combustible building materials also have effect in flame retardation. It will get burnt as soon as it meets open fire or high temperature, so it can easily give rise to rampant fire, such as wooden pillars, wood roof trusses and wooden stairs.
Q:What's the fire resistance test method of doors and roller shutters?
Fire resistance test method of doors and roller shutters: This standard specifies the fire resistance test method for roller shutter doors under standard fire conditions. The method is used to test the fire resistance of the ventilating duct when bearing the external fire (A duct) and internal fire (B duct). Fire resistance test of vertical ducts may be conducted referring to this standard. 1.Test specimen1.1 The test specimen is obtained by cutting from any part of the qualified metal tube unless otherwise relevant standard or mutual agreement specifies the cutting position of the metal tube. 1.2 Length of the specimen: L≈2.5D+50mm (D: outer diameter of the metal tube). The cut surface of the specimen must be perpendicular to the axis of the metal , and the seamed edge of the cut should be round off. Test method GB243-82 of metal tube necking 2. Test procedures 2.1 In the test, punch or press the metal tube into the tapered conical seat (see Figure) with a hammer or press machine, and make it uniformly diminished to the regulated shrinkage X which is calculated according to the following formula: Test method GB243-822 for metallic pipe necking: The inner wall of the seat cover used in the test should be polished, and has certain hardness and is coated with lubricating oil. Its conicity is 1:10, 1:5 or others in accordance with relevant standard provisions. If there is no provision, then adopt the conicity of 1:10. This standard is not suitable for: a) The pipeline whose fire resistance depends on the fire resistance of the ceiling; b) The pipeline with access door, unless otherwise the access door is included into the pipeline and tested together; c) The pipeline with two or three sides; d) Fume exhaust pipes;
Q:Is it normal for caable fire resistant material to catch on fire?
Abnormal, preventive measures: 1 take fire preventive measures. Measures taken for fire retardant measures of cable: (1) seal closely with fire resistant materials holes ran by cables through walls, shafts to prevent the cable fire, high temperature gas diffusion and spread when cables are on fire. (2) to wrap the cable with the insulation refractory material, when the cable is surrounded with fire, warpped cable is insulated by the insulation material from fire, so it will not be burned. If the cable itself is on fire, fire will be extinguished thankes to lack of oxygen in warpped cable, to avoid the fire to spread out. 2 to strengthen the cable circuit switch and regular protective check and maintenance, to ensure that the action is reliable. 3 to strengthen the cable operation and monitoring, to avoid the overload of the cable operation. . 4 regularly clean dust on the cable, to prevent cable from catching on fire due to the accumulation of dust. 5 to ensure the construction quality, the quality the cable must be strictly in line with the requirements and standards. 6 cable laying should maintain enough distance form the heat pipe, control cable is no longer than 0.5 meters; power cable is no longer than l meters. Control cable and power cable should be divided into slots, be layered and seperated instead of being overlapped . For the parts that do not meet the requirements, measures must be taken to insulate heat and fire. 7 regularly teat cable , abnormal problem should be handled in a timely manner. 8 install fire alarm so that fire will be discovered on time, and cables will not catch on fire. 9 the cable trench should be kept dry to prevent the cable from being affected with damp, or leading to declined insulating function and short circuit.
Q:How to distinguish the fire resistant level of construction materials?
Building materials fire resistant level is divided into four levels, among which the first level is the highest, with strongest fire resistance; fourth level is the lowest with weakest fire resistance. Fire resistance level of buildings depends on combustion performance and fire endurance of the building components. The building components refer to a series of basic components such as the building walls, foundations, beams, columns, floors, stairs, ceiling, etc.
Q:How to choose the material of refractory?
Long using temperature of aluminum oxide fiber is 1400 ℃, containing chromium aluminum silicate fiber, quartz, high purity aluminum silicate fiber, long-term use of temperature is 1000-1200 ℃ has aluminum silicate refractory fiber according to different raw materials, advanced refractory fiber (such as alumina. Commonly used vitreous aluminum silicate refractory fibre is amorphous, zirconium oxide refractory fibre) using temperature is 1700 ℃ view as >and the best temperature is 1300 ℃. Crystalline refractory fiber are polycrystalline mullite fiber, including ordinary aluminum silicate fiber, alumina and graphite refractory fiber, etc. The use of common refractory fiber temperature is 1150 ℃;>
Q:How to determine the fire resistance rating of the aluminium-plastic?panel?
Fire rating of the best aluminium-plastic?panel in the current market is B1 class, and its grade classifications can refer to the national standard. I have examined factories and tested the fireproof effect of the fire-proof plate myself by burning it, and I have found that the fire-proof plate of Jinwei Aluminium-plastic?Panel in Linyi is really good in quality and fire prevention. In other words, from the single point of fire rating, the corresponding fire rating of the called fireproof aluminum (plastic) composite panel should be at least B class, and for A2 class fireproof aluminum composite panel, its core material currently doesn't include plastic element, so it's called aluminum composite panel which is of inorganic core material. If the ordinary aluminum-plastic panel is classified according to the fire-proof building material, it will belong to that of lower level. For aluminum-pastic panel used in business premises, it is required to reach the grade of flame retardant material or above this in fire prevention. It is expressly stipulated that its fire rating should be A2 class in public places.
Q:Which industry does refractory belong to?
It belongs to inorganic refractory: Ceramic refractory bricks (used in steel-making furnaces) There is also organic polymer in heavy industry: Halogen-containing and halogen-free It belongs to construction industry.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords