• Raw Materials for Refractory:Dead Burnt Magnesite MgO 97% System 1
  • Raw Materials for Refractory:Dead Burnt Magnesite MgO 97% System 2
Raw Materials for Refractory:Dead Burnt Magnesite MgO 97%

Raw Materials for Refractory:Dead Burnt Magnesite MgO 97%

Ref Price:
get latest price
Loading Port:
Dalian
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
2000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing
ItemMgOSiO2CaOLOIB.D.(g/cm3)
DBM-97970.71.40.23.2
DBM-96961.51.50.23.2
DBM-95952.21.60.33.2
DBM-949431.60.33.2
DBM-93933.51.60.33.2
DBM-929241.60.33.18
DBM-929241.60.33.18
DBM-91914.51.60.33.18
DBM-90904.820.33.18
DBM-878772.20.33.2

Dead burned magnesite- DBM-is produced using selected natural magnesite that is purified and is calcined in a shaft kiln.The final product is used for electric furnacefloors and furnace liner tamping.

Main products level :

0-1mm;1-3mm;3-5mm;0-10mm;0-30mm

50 to 325mesh (90% through)

Product feature:

high temperature performance and high-density, strong anti-permeability ability and easy to rapid sintering, very thin sintered layer,good thermal shock stability, strong slag-resistance, long service life and so on.

Product function:

Apply to the construction of bottom and wall of all kinds steel making electric arc furnace and ferroalloy smelting furnace for hot charging of hot metal and second hand steel

Product usage:

Mainly used in producing common magnesite brick, magnesite aluminum brick, magnesite chrome brick, gunning mix, hot patching mix for converter and EAF ect .

Product Advantage:

Our factory produce the products of the Dead-burned magnesite are selected natural magnesite, it is produced by mine-selecting, purifying, calcimine in shaft kiln. It is an ideal material for unshaped refractory material, the final products are used in open hearth furnace, electric furnace bottom and furnace's lining tamping.

Q: Who knows what is the requirement for fireproofing of interior decoration materials ?
In addition to the underground building, combustion performance level of interior decoration materials inside windowless room , in addition to a class, should advance 1 level based on the original provisions . Library, archives and rooms storing artifacts, ceilings, walls should use class A decoration materials, and the ground should use decoration materials no lower than class B. When high temperature parts of lighting and lighting lamps and lanterns are close to non - grade A decoration materials should be taken, fire prevention measures such as thermal insulation and heat dissipation must be taken. Combustion performance level of materials used for lighting should be no lower than B. Kitchen ceiling, wall and floor should used class a decoration materials.
Q: How long does it take for refractory cement to solidify?
1. First you should be aware of the concepts of condensation and condesation time. Refractory cement belongs unshaped refractories, which when added water or liquid binding agent to mix, the agitation material will gradually lose thixotropy or plasticity and become in a state of solidification, thus is solidified. The time needed to finish the process is called solidification time. The whole process is divided into initial and final set. When beginning to lose plasticity called the initial setting, when called plasticity completely lost the final setting. 2. For refractory cement, the solidification time depends on the matching of the material and the parts and using methods. Under normal circumstances, in order to meet the requirements of time of construction, the initial set time should be no shorter than 40min, and the final set time should be no longer than 8H 3. There are also some exceptions. When refractory cement is used for spraying and injection operation together with other refractory castable, the set time is required as short as possible, sometimes flash set is required to prevent the occurrence of peeling or collapse of the spraying layer.
Q: I want to consult the fire resistant level standards of external wall thermal insulation materials.
1, The building with the height larger than or equal to 100m, should have the A-level combustion performance. 2, The thermal insulation material of the building, with a height larger than or equal 60m and less than 100m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each level should set horizonal fire barrier zone. 3, The thermal insulation material of the building, with a height larger than or equal to 24m and less than 100m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each two levels should set horizonal fire barrier zone. 4, The thermal insulation material of the building, with a height less than 24m, should not be less than the level B2 combustion performance. When using the level B2 insulation material, each three levels should set horizonal fire barrier zone. I hope my answer will help you. Thank you!
Q: What characteristics do A grade external wall fireproofing material have?
For characteristics of A grade external wall fireproofing material, its main raw material uses cold resistant and thermal insulated, environmental protection and energy saving material with good insulation, keeping the indoor temperature steady and making the environment more comfortable. It is several times better than other masonry in overall strength and resist capability, and it can also hang heavy objects such as air conditioners by directly nailing or installing expansion bolts. Single point hanging machine can withstand heavy objects with the weight of more than 45kg. It can also be directly fixed to the tiles, wallpaper, wooden plaques, paint, etc.
Q: For refractory knowledge. What is the ratio of clay ramming?mass?
Soil aggregates, dispersing agent, water reducing agent, plasticizer, binding agent and powder! ~ Bone meal feed approximately 6, OK
Q: Who knows how to divide the building fire grade and fire resistance grade?
I hope to help you building fireproof rank division is one of the most basic measure in building fire safety technical measures, Building's fireproof rank is divided into class one, two, three, four according to China's architectural design specification. Fire-resistant capability of the highest level is the strongest; Fire resistance of four level of the weakest. The fire resistance level of a building depends on the combustion performance and fire resistance of the building components that comprise the building. The so-called building component refers to a series of basic components, such as wall, foundation, beam, column, floor, stair, ceiling and so on.
Q: What are the fireproofing materials of the external wall included?
Facades a fireproof material comprises three anti-cloth, fireproof cloth, plastic cloth, PVC tarpaulins, flame retardant cloth, Hair Dryers cloth, automobile tarpaulin, PVC three anti-cloth, the freight yard covered cloth, PVC coated fabric, canvas industry etc., are widely used in automobile canopy cover cloth, trains cover cloth, ships cover cloth, cloth covered open-air yard, industrial and agricultural fields; used in glass, timber, fertilizer plants, steel plants, machinery metal factory, feed mill, grain storage, container plants, oil refineries, packaging plants, paper plants, air conditioning plants, logistics, ore factory, fleet, rail, sea and so hoping to help you
Q: How to choose the material of refractory?
Long using temperature of aluminum oxide fiber is 1400 ℃, containing chromium aluminum silicate fiber, quartz, high purity aluminum silicate fiber, long-term use of temperature is 1000-1200 ℃ has aluminum silicate refractory fiber according to different raw materials, advanced refractory fiber (such as alumina. Commonly used vitreous aluminum silicate refractory fibre is amorphous, zirconium oxide refractory fibre) using temperature is 1700 ℃ view as >and the best temperature is 1300 ℃. Crystalline refractory fiber are polycrystalline mullite fiber, including ordinary aluminum silicate fiber, alumina and graphite refractory fiber, etc. The use of common refractory fiber temperature is 1150 ℃;>
Q: What are the best refractory materials in 2,400 Celsius degree?
You can try zircon sand which has a melting point of 2430.
Q: What is the mechanism of the errosion of the iron to the refractories?
For example, the effect of the iron oxide: Mo corundum given temperature Fe2O3 solid solubility limit of the solid solution formed of corundum stone high solubility than the solid solution Mo Mo corundum lattice shape so Fe2O3Al2O3-SiO2-based material starts melting temperature of the system or the content of Al2O3 and Al2O3 / SiO2 ratio off Al2O3 / SiO2 & lt; 2.55 starting melting temperature of 1380 ℃ when Al2O3 / SiO2 & gt; 2.55 start melting temperature is increased 1460 ℃ and with its Al2O3 content increased gradually to increase the original atmosphere Fe2O3 original FeO off the solvent into the glass phase and the system starts melting temperature drops do not fall to 1240 ℃ 1380 ℃. Lower the melting point, increase the erosion, and reduce the life span.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords