Medium Voltage Drive VFD 3200KW 10KV HIVERT-Y 10/243
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
The general MV VFD has the following protection functions and features:
Overload and over-current
Phase loss and grounding
Over voltage
Overheat
Current limit
Redundant control power supply
Cell Bypass (optional)
Cabinet door alarm
Phase-Lock function
Synchronous Switching between VFD and Grid system
Soft start of motor
High efficiency >98% (VFD at full-load)
Electrical Isolation by the optic fiber
Built-in PID regulator
RS485 communication with the protocol, Modbus as standard, optional Profibus-DP, Ethernet,etc
Accurate fault records, easy to check fault history
Compact structure and layout, customized design is available
- Q: Laptop power adapter is broken, which brand is better domestic
- What brand of your laptop brand? It is best to be original,
- Q: Can the laptop power adapter be generic?
- Output voltage, current, interface can be used as well.
- Q: What is the difference between variable frequency motor and variable speed motor?
- The variable frequency motor requirements are high, are special motor, so the general motor can not use the inverter to speed. According to the above formula, it can be seen that increasing the frequency, the motor speed will be faster, reduce the frequency of the motor speed is slow, variable frequency motor core is also a special material, because the ferromagnetic material There is a saturation period, to the saturation period, regardless of whether the motor current increases, the motor will not continue to increase the intensity of the magnetic field,
- Q: Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
- Is the inverter must be. Do not know you are also a generic vector. If it is common to directly on the instructions on the motor logarithmic change 6 pole, turn the number changed to 980 on the line. Vector, then change the number of 980 and then learn from the line on the line.
- Q: How does the variable frequency motor output torque at very low frequencies?
- 1, to improve the slip of the inverter compensation coefficient 2, to improve the continuous lifting coefficient of the inverter, but the coefficient is too high there will be overcurrent. 3, with no sensor vector control can increase the motor output torque or encoder with the vector control can make the motor at low frequency to achieve the rated output torque.
- Q: Yaskawa inverter reported base blockade what is the reason?
- This is the base block command, when the external input block command signal, the inverter will appear this code, the code appears, the motor will be free to rotate, does not affect the use.
- Q: With the inverter control fan 37Kw4 pole with what model inverter
- If the speed is not very high requirements, all the general-purpose inverter can be.
- Q: The notebook power adapter flashes
- It seems you are still a novice ~ know the output voltage with the current is not ~ know the words to dig treasure shop name marked (days and along the power adapter) to find it ~ you have to ~ the price will not be expensive ~ I am in the days of business with the company Repair ~ ~
- Q: Do not the laptop directly connected to the power adapter?
- "Notebook do not power adapter", can only use the internal lithium battery power supply work. It can not directly use 220V AC power supply for it. 1, because the notebook product design power supply standard, is to use the matching power adapter power supply. That is, the power adapter will 220V civilian AC, rectifier filter, and then converted to low-voltage 19V DC, for the notebook to provide power supply;
- Q: 55 瓩 4 pole motor with a frequency of one hour can save much electricity
- it is used in the fan pump load can save about 14-22 kWh, used in the general category, on Multiply your number by 55.