• Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154 System 1
  • Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154 System 2
Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154

Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154

Perfect Power Output Section

The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:

1. No need for the additional output filter

2. Directly driving general synchronous or asynchronous motor

3. No de-rating operation on the motor

4. No dV/dt stress on the insulation of motor and cables

5. No torque ripple, extending service life of motors and mechanism

6. No cable length restriction within the acceptable voltage drop.

 

Features

Front access design for easy maintenance of power modules that can be replaced in just a few minutes.
∙ Single power cell design for all modules allows reduced spare parts inventory cost.
∙ 2-Quadrant and 4-Quadrant versions available.
∙ Fibre-optic interface for safe control and feedback communication with controller.

 

Monitoring(HMI)

Door-mounted easy-to-use 7-inch color LCD touch-screen Main panel
∙ User-friendly interface with operational data at your fingertips
∙ Virtual meters display main VFD parameters
∙ System and status monitoring and manual controls
∙ Power module status monitoring
∙ Data logging, trending displays, diagnostic information available
∙ Multiple languages available
∙ Parameter adjustment and operation records
∙ Dedicated multi-level menu to guide user with different access levels for service and commissioning engineers (Operator, Manager and Administrator)

 

 FAQ

1.what kind of load the frequency inverter used for? 

2.Please provide specific motor parameters ?

3.Application Environment 

4.if need special internet port?

 

Q: What parts of the inverter composition
Frequency control technology is an important development direction of modern power transmission technology, with the development of power electronics technology, AC frequency conversion technology from theory to practice gradually mature. Inverter not only smooth speed, large range, high efficiency, start current is small, smooth operation, and energy saving effect is obvious. Therefore, the exchange frequency control has gradually replaced the traditional traditional slip speed, variable speed control, DC speed control system, more and more widely used in metallurgy, textile, printing and dyeing, smoke machine production lines and buildings, Water supply and other fields. However, due to the environment, the use of life and man-made operation and other factors, affecting the life of the inverter greatly reduced, while the use of a variety of failures have occurred. Here we are on the composition of the inverter and common problems and countermeasures and we discuss. Generally divided into rectifier circuit, flat wave circuit, control circuit, inverter circuit, and so on several major parts.
Q: Three-phase asynchronous AC motor speed control method
Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor loop into the adjustable additional potential to change the motor slip, to speed control purposes. Most of the slip power is absorbed by the additional potential in series, and the additional device is used to return the absorbed slip power to the grid or to convert the energy. According to the slip power absorption and utilization, cascade speed can be divided into motor cascade speed, mechanical cascade speed control and thyristor cascade speed form, the use of thyristor cascade speed, which features: Can be transferred in the speed of the process of slip loss back to the grid or production machinery, the higher efficiency; Device capacity and speed range is proportional to the investment province, for the speed range of 70% -90% of the rated speed of production machinery; Speed ??control device failure can switch to full speed operation, to avoid shutdown; Thyristor cascade speed power factor is low, the greater the impact of harmonics. This method is suitable for use in wind turbines, water pumps and rolling mills, mine hoists, extruders.
Q: Laptop computer about electricity no electricity, is the power adapter problem?
To judge this is very simple: 1. The computer is in the battery state to see if it works properly. If it does not work, the battery has a problem 2. Remove the battery from the computer with a power adapter to see if it is working properly. If not, there is a problem with the power adapter 3. If the two states can work that is the computer charge management part of the poor contact and other issues.
Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
The frequency changer mainly consists of rectifying (alternating current direct current), filtering, re-rectifying (direct current alternating current), braking unit, driving unit, detecting unit micro-processing unit and so on. Motor asynchronous speed expression bit: N = 60 f (1-s) / p (1) Where n --- the speed of asynchronous motor; f --- the frequency of asynchronous motor; s --- motor slip; p --- motor pole pairs. From the formula (1) we can see that the output speed of the motor is related to the input power frequency, slip rate and the number of pole pairs of the motor. Therefore, the direct speed regulation mode of AC motor mainly has variable speed (adjustment P), rotor Resistance speed control or cascade speed or internal feedback motor (adjust s) and frequency control (adjust f) and so on. And we now use the most widely used is the frequency control, from the speed n is proportional to the frequency f, as long as the change in frequency f can change the motor speed, when the frequency f in the range of 0 ~ 50Hz, the motor speed adjustment range is very width. The inverter is to change the motor power frequency to achieve speed adjustment, is an ideal high efficiency, high performance speed control means.
Q: Notebook plug in the power adapter lights, but can not open the machine
This is a contradictory problem: First, the power adapter lights because the power is good, but does not mean that the computer is good; Second, can not open the machine with the power adapter is lit, it is your computer reasons. Recommendation: Check the computer hardware. Asked: But the battery can be used to start ah answer: Remove the battery plug in the adapter or put the battery installed plug in the adapter, if you can not open the machine, then it is a hardware conflict. The solution to the hardware conflict is that you try another adapter. Asked: the battery removed to die, but as long as there is a battery can answer: it shows that your adapter is bad. Asked: the more magical is plug in the adapter and the battery, the battery will not consume Answer: get you electronic city so that they give you a test. You can say to buy an adapter, and then try, you can use the words to buy, can not use the words and then think of other methods.
Q: Delta VFD-F frequency converter how to adjust the number of poles
Look at the 07 motor parameters, I VFD-F instructions need, then the mailbox sent
Q: The laptop's power adapter is broken how much it costs
Buy a new, new price of dozens to one hundred. Notebook adapter, as long as the output current is greater than the old, the same voltage, with the brand can be interchangeable, Different brands of adapters to meet the above requirements, that is, insert the notebook connector is different, you can use scissors + tape,
Q: Lenovo g450 laptop power adapter specifications is what?
Input: 100-240V ~ 1.5A 50-60Hz Output: 19V - 4.74A
Q: What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
First of all you have to understand the difference between variable frequency motor and ordinary asynchronous motor. 1, inverter motor cooling fan is not connected with the motor spindle, is independent, the fan rotation from the motor speed, to ensure that the motor cooling.
Q: Does the inverter set the number of poles to match the number of poles of the motor?
The number of motor poles corresponds to the speed of the motor, the number of poles is not set when the speed of the control error, in the high speed requirements of the transmission is not allowed.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords