Perfect Power Output Section
The HIVERT general MV VFD adopts the power cells connected in series and voltage overlapping method (i.e. Power cells multi-level cascade technology), it can output the perfect PWM sinusoidal waveform (see Figure 2 and Figure 3). It has the following advantages:
1. No need for the additional output filter
2. Directly driving general synchronous or asynchronous motor
3. No de-rating operation on the motor
4. No dV/dt stress on the insulation of motor and cables
5. No torque ripple, extending service life of motors and mechanism
6. No cable length restriction within the acceptable voltage drop.
Features
Front access design for easy maintenance of power modules that can be replaced in just a few minutes.
∙ Single power cell design for all modules allows reduced spare parts inventory cost.
∙ 2-Quadrant and 4-Quadrant versions available.
∙ Fibre-optic interface for safe control and feedback communication with controller.
Monitoring(HMI)
Door-mounted easy-to-use 7-inch color LCD touch-screen Main panel
∙ User-friendly interface with operational data at your fingertips
∙ Virtual meters display main VFD parameters
∙ System and status monitoring and manual controls
∙ Power module status monitoring
∙ Data logging, trending displays, diagnostic information available
∙ Multiple languages available
∙ Parameter adjustment and operation records
∙ Dedicated multi-level menu to guide user with different access levels for service and commissioning engineers (Operator, Manager and Administrator)
FAQ
1.what kind of load the frequency inverter used for?
2.Please provide specific motor parameters ?
3.Application Environment
4.if need special internet port?
- Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
- If the frequency converter is selected according to the motor rated current, then the motor current exceeds the rated current, the inverter will become overcurrent protection In this case, that is, when the inverter began to select the amount of time to stay the lack of the same power, inverter general type than the fan pump type current capacity of a high grade If the inverter selection is no problem, then please see whether the inverter is working temperature is too high, too high will cause the electronic components to resist the decline in current. First, check the inverter to work the ambient temperature, the second Please check the inverter fan is damaged, clean down the inverter fan channel and fan to see if there is no plug
- Q:380V 2 pole motor can use the inverter?
- Special attention, variable frequency motor with the ordinary different, easy winding film damage
- Q:How does the spindle drive system of the inverter realize the positive and negative control of the main pole?
- Communication can reach a longer and more stable, generally better of the city 485
- Q:Delta VFD-F frequency converter how to adjust the number of poles
- P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
- Q:What is the difference when using inverter frequency conversion ordinary motor and variable frequency inverter motor
- So that mainly depends on your application and the frequency of work in the number.
- Q:Taian inverter 3.7KW 380V with 4.0KW 2 pole motor 18000 to 300HZ can it?
- Second, is the higher speed, parking, inertia, the motor into a generator, to the module reverse power supply, resulting in the module burned, this time, should consider adding braking resistor and braking unit.
- Q:First reduce the frequency of about one-third of the test, not the case, then appropriate adjustments!
- In the inverter in the following 18.5kw inverter will bring their own braking unit for some special occasions, such as the inverter at high speed due to production needs, must be 1 second, or less time to stop, in the stop when the frequency The internal DC bus voltage is too high, the inverter will be reported over-voltage fault, in the positive and negative connected bk-dk connected to a resistor to the inverter discharge, the inverter will not report over-voltage failure
- Q:What is the motor series parameter setting of the inverter? If it is with the spindle,
- The motor series setting of the inverter should be set according to the series of motor
- Q:A water supply project, how to choose electrodes and frequency converters, such as giving a 7-storey water supply
- 3. Take a doorway as an example: choose DN50, N = 7.5Kw enough. About 50 cubic meters / H.
- Q:Can the notebook's power adapter be mixed?
- At present, the market sales of notebook power is generally 90 watts and 65 watts two, using integrated graphics, or configure the low-end notebook, usually 65 watts. Using the independence was, the configuration of high-end, or the game audio and video of this, are generally 90 watts. If the laptop's power adapter is damaged can not be used, it is best to repair the department as soon as possible to repair. If it is for emergency, before using the two adapters to check the output power and current and voltage are conceded, as the adapter input current and voltage is not the same, should be the general household voltage is 220V, so almost all of the notebook power The adapter is 100-240V ~ 1.5A words, as long as the output current and voltage values, and wattage equal, and then one is the same interface, you can mix. In general, the voltage is stable, the output wattage is the same, the notebook is basically no harm.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Medium Voltage Drive VFD 1250KW 6KV HIVERT-Y 06/154
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 100000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords