1-port 10/100BASE-TX and 1-port 100BASE-FX
12 to 48VDC Power inputs
-10°C to 60°C (14°F to 140°F) operating temperature range
Provides DIN-Rail mounting
Full wire-speed forwarding rat
Features of Media Converter Series
Provides 1-port 10/100BASE-TX plus 1-port 100BASE-FX
The fiber port is available with SC or ST with a fiber connection that can reach up to 120Km (74.4miles)
-10°C to 60°C (-14°F to 140°F) and is tested for functional operation @ -20°C to 70°C (-4°F to 158°F)
10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX
Supports 12 to 48VDC Power inputs
Complies with IEC61000-6-2 EMC Generic standard immunity for Industrial environment
384K bits buffer memor
Technology of Media Converter Series
Standards
IEEE802.3 10BASE-T,IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x
Forward and Filtering Rate
14,880pps for 10Mbps
148,810pps for 100Mbps
Packet Buffer Memory
384K bits
Processing Type
Store-and-Forward
Half-duplex back-pressure and IEEE802.3x full-duplex flow control
Power
Input
Input Voltage: 12 to 48VDC (Terminal Block)
Power Consumption
4.3W Max. 0.3A @ 12VDC, 0.15A @ 24VDC, 0.07A @ 48VDC
- Q:How many power illuminator can 5Kva 36V transformer drive?
- By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
- Q:Why should lighting transformers be used in factories and mines?
- But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
- Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
- Q:What's the function of the lighting transformer?
- In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
- Q:Why is elevator lighting transformer installed?
- Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
- Q:Is the substation separate from the power and illumination transformer?
- The power and illumination of the substation are all used on a transformer, which is separated by power and lighting by the station screen of this transformer.
- Q:Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
- The sectional area of the wire can be calculated according to the electric power formula. The current required by the wire is calculated, and then the reference to the national standard "500 volt copper core insulated wire, long term continuous load allowable ampacity meter" is selected.
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Because some transformers are connected to 380V and 0, they can be 1000VA capacity, but because of the same line diameter, the 220V terminals and 0 can not provide the capacity of 1000VA.
1. Manufacturer Overview |
|
---|---|
Location | Taiwan,Taiwan |
Year Established | 2003 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Northern Europe |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | 91% - 100% |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Media Converter Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Pieces pc
- Supply Capability:
- Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords