Features of Ethernet Switch Series

 

Provides flexibility of 8 Ethernet ports that configure in combinations of copper and fiber optic interfaces

 

 Redundant power inputs with Terminal Block or DC Jack

 

 20°C to 60°C (-4°F to 140°F) and is tested for functional operation @ -30°C to 70°C (-22°F to 158°F)

 

10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX

 

Complies with IEC61000-6-2 EMC Generic standard immunity for Industrial environment

 

Alarms for power failure by relay output

 

Standards:

 

IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX/100BASE-FX, IEEE802.3x

 

Forward and Filtering Rate:

 

14,880pps for 10Mbps

148,810pps for 100Mbps

 

Packet Buffer Memory:

 

768K bits

 

Processing Type:

 

Store-and-Forward

Half-duplex back-pressure and IEEE802.3x full-duplex flow control

 

Address Table Size:

 

2048 MAC addresses

 

Power

Input:

 

Input Voltage: 12 to 30VDC (Terminal Block); 12VDC (DC Jack)

 

Power Consumption:

 

4.8W Max. 0.38A @ 12VDC, 0.2A @ 24VDC

 

Reverse Polarity Protection:

 

Present

 

Mechanical

Casing:

 

Aluminum case

IP30

 

Dimensions:

 

50mm (W) x 125mm (D) x 135mm (H)

(1.97" (W) x 4.92" (D) x 5.31" (H))

 

Weight:

 

0.8Kg (1.76lbs.)

 

Environment

Operating Temperature:

 

-20°C to 60°C (-4°F to 140°F)

Tested @ -30°C to 70°C (-22°F to 158°F)

 

Storage Temperature:

 

-40°C to 85°C (-40°F to 185°F)

 

Ambient Relative Humidity:

 

5% to 95% (non-condensing)

 

Regulatory Approvals

ISO:

 

Manufactured in an ISO9001 facility

 

Safety:

 

UL60950-1

 

EMI:

 

FCC Part 15, Class A

EN61000-6-3

EN55022

EN61000-3-2

EN61000-3-3

 

EMS:

 

EN61000-6-2

EN61000-4-2 (ESD Standards)

Contact: + / - 4KV; Criteria B

Air: + / - 8KV; Criteria B

EN61000-4-3 (Radiated RFI Standards)

10V/m, 80 to 1000MHz; 80% AM Criteria A

3V/m, 1400 to 2000MHz; 80% AM Criteria A

1V/m, 2000 to 2700MHz; 80% AM Criteria A

EN61000-4-4 (Burst Standards)

Signal Ports: + / - 4KV; Criteria B

D.C. Power Ports: + / - 4KV; Criteria B

EN61000-4-5 (Surge Standards)

Signal Ports: + / - 1KV; Line-to-Line; Criteria B

D.C. Power Ports: + / - 0.5KV; Line-to-earth; Criteria B

EN61000-4-6 (Induced RFI Standards)

Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A

D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A

EN61000-4-8 (Magnetic Field Standards)

30A/m @ 50, 60Hz; Criteria A 

 

Q: How many power illuminator can 5Kva 36V transformer drive?
The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
Q: Why is the two side of the lighting transformer grounded?
Single-phase transformer two side lighting to the ground, on the one hand is the lighting products now contain many semiconductor devices such as diodes, transistors, integrated circuits, semiconductor devices vulnerable to electrostatic damage, two side grounding contributes to the surge pressure factors produced by residual electrostatic discharge stay in the main circuit, avoid electrostatic protection, product life. In the 21 aspect, there is distributed capacitance between the two side and the primary side of the power transformer, and the high frequency surge disturbance caused by the primary side current source will directly enter the two side to the main circuit through the distributed capacitor. These unnecessary high frequency interference may jump into the sensitive signal source, make the control system malfunction, and the two side grounding of the power transformer can eliminate most of the undesirable effects of the distributed capacitance.
Q: The difference between lighting transformers and control transformers
A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
Q: Why is elevator lighting transformer installed?
3 a power outlet shall be provided at the bottom pit.4 the cables and wires laid in the hoistway shall be flame retardant and damp resistant, and shall be protected by a nonflammable wire, conduit, or wire slot, with no use of wires, conduits, or wire slots made of combustible material.5 an elevator attached to a building whose wiring, materials and methods and electrical components used shall take into account the effects of climatic conditions and shall take waterproof measures.Lighting transformers in order to obtain 36V voltage
Q: How is the lighting power of the 380V transformer calculated?
Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
Q: How to calculate the rated capacity of small transformers for lighting purposes?
If the flow of large capacity motor starting current and welding machine, large current flows in a short period of time in the load even when the power equipment capacity can withstand current flow in a short time, but due to a voltage drop excitation electromagnetic switch relief, the motor can not start, damaged or the undesirable phenomenon of welding. Therefore, the voltage drop rate should be calculated as less than 10% of the supply voltage, as calculated below.
Our product managers and engineers are specialized in taking your idea from concept, through design and into completely manufactured products, including the following products.We warmly welcome worldwide clients, and wish our efforts will bring you complete satisfaction.

1. Manufacturer Overview

Location Taiwan,Taiwan
Year Established 2003
Annual Output Value US$1 Million - US$2.5 Million
Main Markets North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe; Northern Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage 91% - 100%
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords