• Plastic Tubes Lasted PPR Pipe Fitting for Irrigation Drainage System System 1
  • Plastic Tubes Lasted PPR Pipe Fitting for Irrigation Drainage System System 2
  • Plastic Tubes Lasted PPR Pipe Fitting for Irrigation Drainage System System 3
Plastic Tubes Lasted PPR Pipe Fitting for Irrigation Drainage System

Plastic Tubes Lasted PPR Pipe Fitting for Irrigation Drainage System

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1000 pc
Supply Capability:
100000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product Overview

The comprehensive technical performance and economic indicator of PP-R are much better than galvanized pipe, UPVC pipe, polyethylene-aluminum compound pipe, PE-X (cross-linked polyethylene) and polybutylene pipe etc. For this reason PP-R is the leading products and widely used for feed-water piping in developed countries in Europe and America.

Nowadays PPR pipes win more attention and have been used all over the whole world more widely with its excellent sanitization performance, high heat resistance, compression resistance, corrosion resistance, pliability and seismic performance which make PP-R the real environmental friendly pipe.


Advantages

1. Light weight, easy and quick assembly

2. Most suitable for carrying drinking water

3. Excellent corrosion and chemical resistance

4. Bacteriologically neutral

5. Low thermal conductivity

6. Safe and watertight joints

7. Reduce heat loss

8. Resistance to scaling

9. Resistance to frost

10. Usable in seismic areas

11. Resistance to abrasion

12. Resistance to stray current

13. Eco-friendly

14. Long operational durability


Product Description

1.Material   :

PPR

2.Color:

White,   Gray, Green, or as you required.

3.Size:

20-110mm

4.Logo:

CMAX   or Customized

5.MOQ

500pcs

6.Samples   Time:

(1)   4-5days-If you want to customize your logo.

(2)   1day-For our existing samples for reference.

7.OEM   Accepted

Yes

8.Certification   available:

Yes

9.Packing   Details:

Weaving   Bag

10.Production   Capacity:

5,000,000pcs   Per month.

11.Payment   Term:

(1)   L/C,T/T,D/P


Product Show

Lasted PPR Pipe Fitting for Irrigation Drainage System

Lasted PPR Pipe Fitting for Irrigation Drainage System

Lasted PPR Pipe Fitting for Irrigation Drainage System


FAQ

1. Can you find a translator for me?
You can tell us which language you speak, we will find the translator for you, and will be together work.
2. If we want to develop some new item, but maybe we just have some ideas, how can you do?
We can make new mold base on your idea, generally, if your quantity is more enough, we can refund the mold cost to you.   
3. How Long Is Delivery?
Delivery time will be 30-45 days according to order quantity.
4.What Is Our Normal Payments Terms?
Our normal payment terms: T/T, L/C or western union

Q: An air core is no core except air.
The purpose of a core in a transformer is to ensure as much as possible of the flux from one winding links the other. Also, we want the core to have a very small reluctance, so that the magnetising inductance (sometimes refered to as the mutual inductance) is very large. If it isnt, the transformer will have a large magnetising current i.e. it behaves as a shunt low value inductance, we need this inductance to be very high. Even if the powdered stones in the tube had a low reluctance (maybe they have alot of iron oxides in them?), the problem is that still most of the magnetic circuit is through air, so there is still a high reluctance. You need a closed magnetic circuit with a low reluctance material, or else you will need a very large number of turns on the windings, and they will need to be arranged carefully, to keep the leakage inductance low (flux from one winding that doesnt link with the other...) But what is the application? For low frequency power transformers we want a low leakage reactance and a very high magnetising reactance. For other kinds of transformers we might want a high leakage reactance (say a transformer to be used as a welder, the leakage reactance acts like a series choke to limit the short circuit current...). For broadband high frequency transformers, we want as little leakage inductance as possible, where as low magnetising inductance is not a problem at these frequencies. So usually we make transformers for this application with the two windings as one side of a twisted pair cable, or coax cable, and then have an air core. So how good a transformer core is depends on its application!
Q: and waist, torso of your body, reason why is because i need these materials for building, making a costume for cosplaying, and i'm looking for it in plastic instead of meta
I'm not sure if these are the best solution for you, but... something to consider, at least? Best of luck with your cosplay, in any case! (Is it strange that I'm now really curious what your costume will be? All this tube research has me interested. :y )
Q: Can plastic tubes be used for HVAC lines?
Yes, plastic tubes can be used for HVAC lines. Plastic tubing such as polyvinyl chloride (PVC) or high-density polyethylene (HDPE) can be suitable alternatives to traditional metal pipes for HVAC systems. Plastic tubes are lightweight, resistant to corrosion, and can be easily installed, making them a cost-effective choice for HVAC applications. However, it is important to ensure that the specific plastic material used is compatible with the HVAC system requirements and meets the necessary industry standards.
Q: A 0.596 kg metal cylinder is placed inside the top of a plastic tube, the lower end of which is sealed off by an adjustable plunger, and comes to rest some distance above the plunger. The plastic tube has an inner radius of 7.07 mm, and is frictionless. Neither the plunger nor the metal cylinder allow any air to flow around them. If the plunger is suddenly pushed upwards, increasing the pressure between the plunger and the metal cylinder by a factor of 2.31, what is the initial acceleration of the metal cylinder? Assume the pressure outside of the tube is 1.00 atm.Please answer in m/s^2. Thank you!
Before the sudden push, the net force on the metal cylinder is zero. This means downward force = upward force p0 A + m g = p A, where p0 is atmospheric pressure, p the pressure of the trapped air, m the mass of the metal cylinder, g the acceleration due to gravity and A the inner cross sectional area of the plastic tube. If the pressure p is momentarily increased to 2.31 p, then there is a net upward force of magnitude Fnet_up = 2.31 p A - p0 A - m g = 1.31 p0 A - 1.31 m g This net force gives rise to an acceleration that obeys Newton's second law: m a = Fnet m a = 1.31 p0 A - 1.31 m g a = 1.31 p0 A /m - 1.31 g = 1.31 * 1.01*10^5 N/m^2 * ( pi * (7.07*10^-3 m)^2 ) / 0.596 kg - 1.31 * 9.81 m/s^2 = 22.0 m/s^2
Q: This connector is used with plastic tubing and is inserted into a rubber stopper (which is in turn inserted into a waste flask). The 'wings' are for holding the tubing in place. Previously this connector is believed to have been bought through Fisher Scientific, but recent searches (with out knowing the name of this item) have not yielded results. If anyone has any suggestions of where to obtain this or what this is called it would be greatly appreciated.
This looks a little like a spring clamp, though not any of the ones presently sold by Fisher. Is the purpose just to hold tubing leading into a waste flask? I have been using a clamp-free setup that I put together by forcing a cut piece of a plastic 5-mL pipet through the stopper. The outside diameter of the pipet is just a little bigger than the waste line, so the waste line fits snugly, even under vacuum. You could probably use a small hose clamp from an auto parts store.
Q: Are plastic tubes suitable for outdoor signage?
No, plastic tubes are not suitable for outdoor signage as they are not weather-resistant and may deteriorate or fade when exposed to outdoor elements.
Q: Are plastic tubes transparent or opaque?
Plastic tubes can be transparent or opaque, depending on the type of plastic used and its color.
Q: How can you prove that the PVC plastic pipe is B1?
Because of its harm to human body, Europe, Japan and South Korea and other countries have restrictions on using PVC as raw material and products. PVC resin has the advantages of plastic products is generally difficult to burn, abrasion resistance, chemical resistance, low leakage, good gas vapor. In addition, comprehensive mechanical energy, products transparent, electrical insulation, insulation, noise elimination, shock elimination, or better, is the most superior price than the general type of material. The defect is thermal stability and shock resistance is poor, whether it is hard or soft, PVC is easy to produce brittle during use. General PVC is not containing the relevant national standards allow the use of two (2 - ethylhexyl) adipate plasticizer (DEHA), DEHA in the high temperature (over 100 degrees Celsius) easily released, after contact with human health hazard. Because PVC is a hard plastic, to make it soft, a large amount of plasticizers must be added. Plasticizers are easy to release in a heated environment. If you are using DEHA, it will interfere with the human endocrine, cause women to breast cancer, birth defects, reduce the number of male sperm, or even mental disorders.
Q: Are plastic tubes suitable for packaging beauty or skincare products?
Yes, plastic tubes are suitable for packaging beauty or skincare products. They are lightweight, durable, and offer various sizes and shapes to accommodate different product types. Plastic tubes also provide excellent barrier properties, protecting the product from external factors such as moisture and air, ensuring its quality and longevity. Additionally, plastic tubes are easy to use, convenient, and can be customized with attractive designs, making them a popular choice for the packaging of beauty and skincare products.
Q: What are the differences between rigid flame retardant pipes and semi rigid flame retardant plastic tubes? Who knows?
Semi hard plastic tube, Department of PVC resin and plasticizer, stabilizer and other auxiliary agent, by extrusion molding, suitable for electrical and fluid conveying pipe casing, can be used to protect the wire and cable etc. under normal temperature. The tube is supplied with a length of not less than 10 meters. The colors are white, yellow, red, blue, black and ecru. The pipe connections are usually made of plastic sleevesMaterial glue bonding, bending freely, without heating, construction environment temperature 5--45 degrees, in -15--25 degrees, should use cold resistant (yellow) pipe.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords