Note:
In order to prevent electric shock, the motor and frequency converter must be
grounded before use.
• Do not install the incoming capacitor or surge suppressor, radio noise filter
to the output of the frequency converter. This will lead to the failure of the
frequency converter or the damage of the capacitor and surge suppressor. If any
of the above equipment has been installed, please remove it immediately. When
it is necessary to set a non fuse circuit breaker at the output end, please
consult the manufacturer for the selection of non fuse circuit breaker.
• With regard to electromagnetic wave interference, the input / output (main
circuit) of the frequency converter contains high-frequency components, which
may interfere with the communication equipment near the frequency converter
(such as AM radio). Therefore, EMC filters are installed to minimize
interference.
• For details of peripheral devices, please refer to the user manual of each
option and peripheral device.
• PM motor cannot operate on power frequency power supply.
• Because PM motor is a motor with built-in permanent magnet, even when the
power supply of frequency converter is disconnected, as long as the motor is
still rotating, high voltage will be generated at the motor terminal. When the
output switch is closed, turn on the power supply of the frequency converter
and use it when the motor is stopped.
- Q: The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
- can use. But in the inverter "motor parameters" to be some changes. Such as the number of poles, rated current.
- Q: A 4-pole AC motor into a 2-pole AC motor, the motor is controlled by the inverter, to make the maximum speed of the 2-pole motor and the original 4-pole
- If it is normal V / F control, then do not need to modify too many parameters to limit the frequency limit of 50%
- Q: Motor 2 pole and 4 pole in the inverter with what set to show
- There are parameters for the number of motor poles / pole pairs or the rated speed of the motor in the inverter parameters
- Q: How do I protect the inverter when the three-phase two-pole motor is running?
- Three-phase two-pole motor running inverter protection, should be based on the protection of tips, check the corresponding manual to deal with. When the inverter protection has a corresponding protection tips (such as over-current, over-voltage, speeding, stall ... ... etc.), the product manual will generally give the corresponding protection tips. According to these measures to check, deal with, you can solve the problem.
- Q: If it is 8-pole variable frequency motor, enter the motor nameplate parameters in the inverter input for the 4 pole can?
- According to the number of revolutions N = 60 * f (frequency) / p (pole pairs) can calculate the motor is a few poles. If the motor is 8 pole is not recommended in the inverter set to 4. will certainly affect the control accuracy.
- Q: I have a 5.5 kilowatts of 4-pole motor, want to pass through the inverter, slow down to 130 per minute use, eliminating the need for speed,
- wo recommendations, the first, the use of vector control of the inverter, you are expected to run the frequency of about 5Hz, this time, ordinary V / F inverter output torque may be small, not necessarily meet the requirements, of course, if it is High-end imported inverter, the problem should be small, with the domestic vector inverter, the frequency can also be full torque output;
- Q: How does the variable frequency motor output torque at very low frequencies?
- 50hz the following frequency, u constant, current and frequency is proportional to the frequency down the output current is also down, and torque and current is proportional to the natural torque is small
- Q: Laptop power supply 20V 3.5A can use 20V 4.5A power adapter Mody, what impact?
- It's ok. As long as the voltage is appropriate on the line. Current value refers to the maximum current that can be output. How much depends on your computer. Or, with a big no harm, can only be better, if you can use a small, but a little longer charging time.
- Q: Inverter problem
- (0 ~ 20mA), but the main input / output is completely isolated, than the output of the inverter simulation of the output of the analog output The amount of signal impact resistance, anti-interference ability.
- Q: 18: 5 kilowatts bipolar multi-pole pump motor with inverter
- If you worry about the small, with 18.5KW is far enough.
Send your message to us
Insulating Material Intelligen Inverter FR-A820-11K-1 For Transition Curren
- Loading Port:
- Shekou
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 kg
- Supply Capability:
- 2300 kg/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches