• Hydraulic Fitting Stainless Steel Elbow Pipe Fitting System 1
  • Hydraulic Fitting Stainless Steel Elbow Pipe Fitting System 2
  • Hydraulic Fitting Stainless Steel Elbow Pipe Fitting System 3
Hydraulic Fitting Stainless Steel Elbow Pipe Fitting

Hydraulic Fitting Stainless Steel Elbow Pipe Fitting

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
25 PCS
Supply Capability:
1111 PCS/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1、Structure of Hydraulic Fitting Stainless Steel Elbow Pipe Fitting Description

    Stainless steel pipe fittings is a tube which is made of stainless steel , the products of Stainless steel pipe fittings include: stainless steel elbow, stainless steel tee, stainless steel cross, stainless steel diameter pipe, stainless steel pipe cap, etc., they can be divided into stainless steel pipe fittings, threaded stainless steel pipe fittings, flanges stainless steel pipe fittings and welded stainless steel pipe fittings according to the connection methods.



2、Main Features of Hydraulic Fitting Stainless Steel Elbow Pipe Fitting:  

Relatively light weight


Optional torsional strength


Support high pressure


Resist corrosion


Reasonable price




3 Hydraulic Fitting Stainless Steel Elbow Pipe Fitting Images:








4、Hydraulic Fitting Stainless Steel Elbow Pipe Fitting Specification:

HOT SALE elbow 
1 Type :LR/SR elbow 
2 size: DN15~DN1800 
3.Thickness : 2.8~60mm. 
4.Certificate : ISO9001:2000 ,API. 


The standard of the products


 

 

Standard:

ANSI B16.9/16.28,ASME B36.10M-1996.

JIS P2311 /2312/2313 SGP

DIN 2605 / 2615/2616/2617

GOST 17379-2001 /17375-2001 /30753-2001/17378-2001

API

BS

EN

GB

 

Elbow

DN15~DN1800

Flange

DN~DN4000

Tee

DN15~DN1800

Reducer

DN15~DN1800

Cap

DN15~DN1800

Seamless Steel pipe

DN15~DN600

ERW

DN15~DN1800

SSAW

DN200~DN3600

LSAW

DN300~DN1400

Wall thickness

SCH10-XXS

 

The information of the products

 


Stainless steel elbow

Other productions:

butt welded and seamless pipe fittings ,

such as  tee, cross, cap, bend,

45D/90D/180D LR/SR elbow.

Material:

Carbon steel (ASTM A234WPB, A234 WPC , A420 WPL6 ).

St45.8 A105 A106 STPG42

Stainless steel (ASTM A403 WP304/WP304L/WP316/WP316L).

Alloy steel (ASTM A234 WP12/WP11/WP22/WP5/WP9/WP91).

Size:

Seamless elbow:1/2"~24" DN15~DN600

Welded Elbow: 1/2”~72" DN15~DN1800

Thickness:

SCH10~SCH160,STD ,XS ,XXS sch5s, sch20s, sch40s, sch80s,SGP./ 2.8mm~60mm

Surface treatment:

Transparent oil,

rust-proof black oil

hot galvanized

Productivity:

1000 T/month

 Min order:

 100pieces

Delivery Term:

FOB(30deposite the balance before shipment)

CIF or C&F(30% deposite , the balance aginst with the copy of B/L)

Remark:

1. Special design available according to requirement

2. All the production process are made under the ISO9001:2000 ,API,CCS

 

The applications

 

 

Applications:

chemical industry, water conservancy,

boiler, machinery, metallurgy, construction

Petroleum, power ,gas, shipbuilding




5、FAQ of Hydraulic Fitting Stainless Steel Elbow Pipe Fitting:


①How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.


②How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. The pecific time of receiving is related to the state and position of customers.


③ How can we get more information?

You can contact us by Email or call us directly and we will do our best to give you valuable information as much as possible but this service is not available on weekends.




Q:What type of material will reflect most of the electromagnetic waves coming from a microwave magnetron? What kind of material is the best?
If it affects every fixture in the house than it sounds like the isolation valve is partially closed. The plumber would have shut this off to replace the pipe and probably did not turn it fully back on right away to prevent his fittings from blowing out from water pressure. Check around your hot water heater for a valve on a pipe that feels warm. If it has a lever, the lever must be turned so that it is parallel with the pipe when fully on. If the valve has a knob, turn it counterclockwise until it stops, this is the fully open position. If this problem is isolated to only one fixture, check the stops to the specific fixture to make sure they are fully on. If you have a mixing valve for any of these fixtures, this may need adjusting too. If this doesn't work call the plumber back to repair. It is industry standard to warranty work for at least 1 year.
Q:My girl was naked in the shower and my friend Alex walked in and saw everything.Since, he won't stop staring at her boobs and butt. I think he likes her. But now he tells other people that my girlfriend showed him her pussy.I told him to stop. But, now he is sending her pics of his d*ck and she is getting uncomfortable around me now.What did I do?? I have asked and begged alex to leave her alone.It got really bad when I was fingering my girl and he walked in and videoed her.I tried to get his phone but he locked his phone.What do I do??
under the sink should be some plastic pipes you can purchase from any DIY store an attachment that will have a spigot on it simply attach the fitting to the existing pipe work and attach the hose removing the plastic sleeve that forms the hose into a hook .All the nuts should be hand tight undo them anti clock wise do them up clockwise ensuring all rubber and plastic washers arte put back in the dame order they came out if they atre a bit sticky to do up put a bit of washing up liquid on them .then hook the hose up inside the cupboard as high as you can this prevents water running back into the machine from the sink.Any questions and the staff in store should be able to explain and supply the correct fittings
Q:Yesterday, forgetting there was residue from a fire extinguisher in our oven, i turned it on to prepare some garlic toast. After about 20 minutes, i came back to a very distinctive fishy smell in my kitchen, and when i opened the oven, i got a very big whiff of it. About an hour later, i started getting very stressed and hyper. I felt like i wanted to explode. Also, i was very paranoid, and found myself continually worried somebody was going to break into my house. When i went to bed, i only slept for 30 minutes, even though it felt like i had slept a whole night. When i woke up it felt like i was vibrating in my bed.All in all, it was a very scary experience, especially since i wasn't expecting it. Are their chemicals inside of a fire extinguisher that could get you high like this, or was it something i ate or another external factor?
If you notify your landlord that you will move out until the gas is fixed, she has to prorate your rent for the days you cannot be in the unit. She is not obligated to pay for your hotel or other expenses. If you stay in the unit, you are not entitled to any compensation
Q:I wonder if somebody could tell me how CO2 working as a fire extinguisher, regarding that it is full of oxygen?Or, is it possible that there are is some type of substance that is not possible to extinct with CO2.Is it possible that CO2 make an opposite reaction and enlarge fire?
Pipe dope (joint compound) does not normally dry out. After it is applied it remains soft and pliable, although with time it will form a crusted surface. The pipe dope is used to form a better seal between the threads of the pipe and the fittings. As the pipe and the fittings change temperatures, the materials will expand and contract. If the pipe dope dried out it would crack and begin to leak over time. By remaining pliable it maintains the seal and prevents leakage.
Q:Why do dogs pee on anything upright? Tree, fire hydrant etc?
Standard water heaters in the US come with 3/4 pipe thread fitings, so 3/4 is what you need. Most plumbers tend to use a torch and solder MPT adapters onto straight copper pipe, but there are fittings that are supposed to make the job easier. There are several reasons why your fitting may not work: 1. the threads on your original fitting might be stripped, preventing the new fitting from getting a good seal. 2. you could be getting a different type of pipe thread from the store. 3. you could be overtightening the fitting when you put it together, One solderless solution might be to use a new product called shark bites. You don't have to solder them, they wokr like a compression fitting, but they go together like ridgid copper. (take a look at the attachment)
Q:Do you think clothing is necessary anymore?We have enough control of our indoor environment that we can be comfortable indoors in all weather. With the exception of shoes, it's not used to protect us from anything, and now it's useless as insulation.It seems to me that clothing does nothing but drain our resources and protect our precious sensibilities. Nudity in itself is not sexual it's natural. Clothing also doesn't &prevent rape& for the same reason rape isn't a sexual crime, it's a crime of power, so someone being naked wouldn't &cause rape&.Do you agree or disagree?
Honestly I don't know how to comment on this I think the way you measure accomplishments and I do are very different. Eating certain things early, is not necessarily considered gifted. That said.At the level he is at now physically (pushing things,climbing, opening, closing, pushing buttons, etc) all are typical behaviors for 1 1/2 year old. So if anything he is right on target- which is a good thing. But as far as gifted I think its a little early to determine that.
Q:thereis a 1 foot long piece that comes out from a fitting in the masonry - I don't feel good abouit lighting a wood fire in teh fireplace with the black pipe in there. the end of the blackp pipe is open. Very rusty, can't get the elbow fittings loose. Thinking about cutting off the pipe, but howw to seal it against fireplace heat? Really want to use the fireplace for wood.
The detector is good for localizing the leak, the soap solution is good for pinpointing it. I use a spray bottle with 10 to 1 soap to water for finding leaks.
Q:These are the laser safety goggles I'm thinking of wearing
Copper pipe either has sweat on fittings or are just joined. You need to look at it and see if there is any solder around the elbow or not, either way it is going to have to be cut off and either re-soldered or re-joined. Copper pipe is metal pipe and it just happens sometimes, just like galvanized or PVCit just happens but always fixable.
Q:I already have an airsoft gun. I just would like to be able to skirmish. They think it's really dangerous and I'm going to get shot in the eye through the paintball mask I have. It doesn't make sense but, you know how they are. Any ideas on how to prove to them I can handle it?
Don't know about California but it's been done for generations in Philly and New York as a way for city people to keep cool. blem is , of course, it lowers water pressure in the area and the fire department hates that..so there is a constant firemen turn 'em off people turn 'em on back and forth all summersometimes the cops get involved. Common sense has finally prevailed and the FD puts sprinkler heads on the hydrants.less water loss but still a way fro people to keep cool, especially in neighborhoods w/o public pools
Q:I try to open my control panel or documents and I get a message saying windows explorer is not working and is restarting, it will just disappear after I close those windows and does nothing after that. I also keep getting a message DEP is not working as well, if I try to trouble shoot it, it will not let me. Help me please!!!!!!
Sorry, PVC is not allowed. Black pipe or CSST is normally used. The only plastic like pipe I know of, polymide and polyethylene, is restricted to outdoor or buried use. Keep in mind that there is a thing called the Authority Having Jurisdiction that can make a final determination. This would be the inspector. He has said it is not ok so the code would support him. NFPA 58 is the code book for gas piping although a state may or may not adopt it, or as it seems to be the case in California, may exceed what it says. Your inspector would know this and can provide you the code. Let me look up the code. Here it is 6.19 LP-Gas Systems in Buildings 6.19.2 Additional Requirements 6.19.2.4 Piping shall comply with Section 5.9 and shall have a pressure rating of 250 psig (1.7 MPag). 5.9 Piping (Including Hose), Fittings, and Valves 5.9.3 Pipe and Tubing 5.9.3.1 Pipe shall be wrought iron or steel (black or galvanized), brass, copper, polyamide, or polyethlene. Keep in mind that not all these pipes are for indoor use. ie: Polyamide and Polyethlene: 6.9.4.1 Polyethylene and polyamide pipe, tubing, and fittings shall be installed outdoors and underground only. PVC is not allowed. Since the inspector also says no you need to have the system re-plumbed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords