High Voltage Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Meters m
- Supply Capability:
- 100000 Meters per Month m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
*high voltage copper cable up 35KV
*high voltage copper cable bear 90 degree
*high voltage copper cable do OEM&ODM service
high voltage copper cable is with following features:
high voltage copper cable use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
-Standards / Testing Specications: IEC 60502-1.
xlpe swa pvc cable can be installed in duct, tray or direct burial. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, din standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees
high voltage copper cable with following code and specification:
Code Word | AWG or Kcmil | Bare Neutral Messenger | Phase Conductor | Weight | ||
AL.-ALLOY Stranding and wires Dia(mm) | Rated strength(lbs) | Al. Stranding and wires Dia(mm) | XLPE Insulated thickness(mm) | (kg/km) | ||
Minex | 2*6AWG+1*30.58 | 7/1.68 | 1110 | 1/4.11 | 1.14 | 152 |
prawn | 2*4AWG+1*48.69 | 7/2.12 | 1760 | 1/5.19 | 1.14 | 229 |
Shrimp | 2*2AWG+1*77.47 | 7/2.67 | 2800 | 7/2.47 | 1.14 | 354 |
Cammarus | 2*1/0AWG+1*123.3 | 7/3.37 | 4460 | 7/3.12 | 1.52 | 569 |
Dungeness | 2*2/0AWG+1*155.4 | 7/3.78 | 5390 | 7/3.50 | 1.52 | 702 |
Cyclops | 2*3/0awg+1*155.4 | 7/3.78 | 5390 | 19/2.13 | 1.52 | 703 |
Flustra | 2*3/0AWG+1*195.7 | 7/4.25 | 6790 | 19/2.39 | 1.52 | 869 |
LEPAS | 2*4/0AWG+1*246.9 | 7/4.77 | 8560 | 19/2.68 | 1.52 | 1077 |
CRAB | 2*4AWG+1*30.58 | 7/1.68 | 1110 | 7/1.96 | 1.14 | 208 |
SDCRAB | 2*1/0AWG+1*77.47 | 7/2.67 | 2800 | 7/3.12 | 1.52 | 504 |
- Q: We are now the construction site will all BV line to AF? What is the purpose, AF line in the end where the better
- AF high temperature installation line, temperature level is much higher, ordinary residential do not need so well. This line is usually used in military industry. The Materials are usually made of silver-plated wire, tinned wire and the like, and the use of fluorine plastic. BV is the most common, the most commonly used cloth wire, suitable for general purpose. Material is only copper and PVC.
- Q: What are the characteristics of Teflon heat shrink tubing
- Appendix B Construction Division (sub-division) project, sub-project division B.0.1 Construction Division (sub-division) project, sub-project can be divided according to Table B.0.1Appendix B Construction Division (sub-division) project, sub-project division B.0.1 Construction Division (sub-division) project, sub-project can be divided according to Table B.0.1
- Q: For example: WDZB-YJY-3 * 2.5RVSPWEL, etc. Thank you, I am a novice, just enter more
- Change the original or carefully through the Apple accessories, can be
- Q: What is the difference between a KVVR cable and an RVV cable?
- The small circle on the wire is marked with a number or letter on the line number. It is set according to the line number on the drawing. A complete wire should be the same for both lines. It is for easy installation and maintenance. And used.
- Q: Mechanical parts, standard room, special-shaped pieces, wire and cable, instrumentation. Hardware tools, lifting equipment spare parts what factory to sell
- 2.5 square aluminum can withstand the maximum 10A current, the maximum load of not more than 2200W, but in the heat is not good temperature environment is not used.
- Q: Can KVV control cables be used for home heating?
- Yes, but the installation and installation as long as the provisions can be.
- Q: Who provided the more to the sub-gave to whom, thank you for helping
- Generally with 2.5 square copper wire, or 4 square aluminum can be. 1.5 air-conditioning is only 1 kilowatt, that is, more than 1 hour per hour electricity
- Q: Single-wire and stranded general use, instrument control cable can use a single line?
- As a power line when the multi-strand can effectively avoid the core of the eddy current generation. So the big power lines are mostly twisted together, and this line of softness is good. As a control line or signal line, it is not very care about these, because this line more detailed. The cabinet inside the multi-purpose strand, this type of line is easy to shape out more beautiful. Instrument cable This product is suitable for instrumentation, instrumentation and other electrical equipment in the signal transmission and control lines.
- Q: The difference between the instrument cable and the low voltage power cable
- If the words are used, the difference is not true if the front is the control cable, followed by the power cable
- Q: What is the meaning of kxv in wire and cable?
- According to the drawings when the wiring should be reasonable to find the shortest distance to reduce the cost of water and electricity materials, the strength of electricity in the distribution of wiring.
1. Manufacturer Overview
Location | Yunnan,China |
Year Established | 2005 |
Annual Output Value | Above US$100 Million |
Main Markets | Southeast Asia 0.3% Africa 0.5 % Domestic Market 99.2% |
Company Certifications | ISO 9001:2000;ISO 9001:2008 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen,Guangzhou,Shanghai |
Export Percentage | 21% - 30% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | High and/or Average |
Send your message to us
High Voltage Cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 Meters m
- Supply Capability:
- 100000 Meters per Month m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords