• High pressure water pumps, multistage vertical turbine pumps System 1
  • High pressure water pumps, multistage vertical turbine pumps System 2
  • High pressure water pumps, multistage vertical turbine pumps System 3
High pressure water pumps, multistage vertical turbine pumps

High pressure water pumps, multistage vertical turbine pumps

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
1000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

High pressure water pump, multistage vertical turbine pump

 Features

 

* Straight shaft structure, 2-pole motor,single phase with thermal protector

* Inlet and outlet section are cast iron,

* Impeller and hydraulic stack are PPO, It's economic and high cost-effective multistage pump

 

RANGE OF PERFORMANCE


8Flow rate up to 108 l/min (6.5 m3/h)
8Head up to 105m

 

LIMITS OF USE

 

 8Non-flammable or non-explosive clean liquid without solid grain or fibre.
8Liquid temperature up to 5 °C -  +60°C
8Environment temperature up to ≤  50°C

8Max. working pressure: 1.0 Mpa

 

INSTALLATION 


8These pumps are suitable for handling clean water without abrasive particles and liquids that are chemically 
non-aggressive to the pump components. Reliable, economical and simple to use, they are suitable for 
domestic use and in particular for distributing water in combination with small pressure sets, for irrigating gardens.
The pumps must be installed in a covered area, protected against the inclement weather.

 

MOTOR


8Two –pole induction motor (n=2850rpm)
8Insulation Class F
8Protection grade IP55

 

MATERIALS


8Pump body: Cast iron with stainless steel.
8Pump support: Cast iron
8Motor housing: Aluminum
8Impeller: PPO
8Shaft with rotor: AISI420 stainless steel
8Mechanical seal: NBR/ Ceramic/ Carbon
8Bearing:  NSK, C&U, or local quality.


Q: How can the submersible pump level meter be connected?
The company actively introduce international advanced production equipment and production technology, with its strong technical force, perfect equipment conditions and rich manufacturing practice, constantly development and improvement of pump products, according to the needs of users of innovative products, stable performance, excellent quality, many products export part countries and regions
Q: What's the pump? Where can I use it?
A pump is a machine that transports liquids or pumps liquids. Pumps are ubiquitous in life. They can be used to transport liquids such as water, oil, acid and alkali, emulsions, suspensions and liquid metals, as well as liquids, gas mixtures, and liquids containing suspended solids.
Q: The distance from the pump button to the ground
Yellow warning pop-up, indicating that the fire control room has issued alarm information, fire alarm controller (commonly known as the alarm host)
Q: Why should I pump the pump before starting the centrifugal pump?
Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.
Q: Difference between pump and compressor
In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.The working principle of the linear pump is different from that of any other pump. It adopts the principle of magnetic suspension and the hydraulic structure of the spiral ring to realize liquid propulsion, that is, to cancel the shaft, to cancel the shaft connection, and to cancel the sealing structure of the shaft. After starting, the electric current is transformed into a magnetic field, and the magnetic field force drives the spiral ring to move, namely, the spiral ring promotes the liquid advance.Compressor (compressor), a driven fluid machine that promotes low-pressure gas as a high pressure gas, is the heart of a refrigeration system. It is of low temperature and low pressure refrigerant gas suction pipe from the suction, through the operation of the motor drives the piston to compress it after high temperature and high pressure refrigerant gas discharge pipe to the exhaust, to provide power for the refrigeration cycle, so as to realize the compression and condensation (exothermic), expansion and evaporation (endothermic) refrigeration cycle.
Q: What is the working pressure of the hydraulic pump in the hydraulic transmission system?
Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
Q: Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
Household automatic booster pump is not started by pressure, it is induced water pump, that is boiled water faucet
Q: Why is the flow of the pump too small will occur cavitation phenomenon?
Throttling regulation is to change the opening of the valve to change the flow of the pump, that is to say, to change the characteristic curve of the pipeline. The commonly used to regulate the flow of exports, because the entrance throttle makes reduce the inlet pressure caused by cavitation danger.
Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
Q: Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
If the water pressure is not enough, the pump can not start, then it must be wrong. Because if the water pressure is not enough, the pump should be running automatically. It's just because the water pressure is not enough.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords