• High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 1
  • High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 2
  • High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 3
  • High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 4
  • High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 5
  • High Performance Zircon Sands and Powder:Raw Materials for Refractory Use System 6
High Performance Zircon Sands and Powder:Raw Materials for Refractory Use

High Performance Zircon Sands and Powder:Raw Materials for Refractory Use

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
3000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Zircon Sands and Zircon Powder High Performafce for Refractory Use

1.Structure of Zircon Sand and Zircon Powder

We are offer zircon sand With Below Mention Descriptions: ZrO2 65 - 67 %. We are offer zircon sand With Below Mention Descriptions: ZrO2 65 - 67 %. Zircon is a remarkable mineral, if only for its almost ubiquitous presence in the crust of Earth. It occurs in igneous rocks as primary crystallization products, in metamorphic rocks and in sedimentary rocks as detrital grains. 
Further, the mineral due to hardness, durability and chemical inertness, zircon persists in sedimentary deposits and is a common constituent of most sands.

2.Main Features of Zircon Sand and Zircon Powder

1 Tiny, round, solid ball shape provides greater surface area for improved performance and dispersion in its application

2 High refractory rating, lower specific gravity rating, and higher service temperature produces greater yield

3 With lower bulk density, it offers better air permeability for better performance as a result of its overall physical characteristics

 

3.Main usage of Zircon Sand and Zircon Powder

1. The 80-120M zircon sand is used in investment casting, the processing is called dipping. 
2. It can enhance the shell`s thickness. 
3. It is specialize used in inner layer being mixed with silica sol.

4. Zircon Sand and Zircon Powder Images

 

Zircon Sands and Zircon Powder High Performafce for Refractory Use

Zircon Sands and Zircon Powder High Performafce for Refractory Use

Zircon Sands and Zircon Powder High Performafce for Refractory Use


5. Zircon Sand and Zircon Powder SpecificationFe2O3 Guaranteed: 0.075 max
(total iron as Fe2O3): Typical 0.04-0.07
TiO2 Guaranteed: 0.15 max
TiO2 Typical: 0.06-0.15
ZrO2+HfO2 Typical: 66.0-67.0
Al2O3 Typical: 0.20-0.70
CaO Typical: 0.01-0.04
P2O5 Typical: 0.06 -0.10
SiO2 Typical: 32.0-34.0
Free Silica Typical: 0.01-0.07
pH Typical: 5.5 -7.00
Moisture Typical: 0.01- 0.07 

6.FAQ of Zircon Sand and Zircon Powder

1). Q: Are you a factory or trading company?

A: We are a factory.

2). Q: Where is your factory located? How can I visit there?

A: Our factory is located in China. You are warmly welcomed to visit us!

3). Q: How can I get some samples?

A: Please contact me for samples

 


Q: How to distinguish between class A fire resistant door and class B fire resistant door from appearance ? What are the differences between the two refractories? Thank you !
First, the materials are the same. But the thickness of grade A and grade B fire doors is different juding from their appearances. Grade A :50. Grade B:45. Added question: Do you refer to steel fire door?
Q: What kind of refractory materials are used in metallurgy industry?
Argon-blowing rod, siliceous dry vibrating materials, desulfurizer, slag-stopping ball, stainless steel thermal insulating agent with high efficiency, dry vibration material, sizing nozzle heat-insulating panel, chrome refractory , refractory carstables for ladles, magnesia carbon refractory, package castable, siliceous drainage agent, tundish block, iron trough, deoxidizer, compound deoxidizer,silicon manganese alloy , stemming, floating plug,slagging agent. The main materials are as follows: recarburizer, covering agent, intermediate frequency furnace burden, mould fluxes, insulation thin slag agent, skimmer repair material, joint sealant.
Q: How to make fire resistant materials for building stoves
Legend of the old version has been upgraded, or can not enter the server, is not legend stopped?
Q: What is the appropiate thickness if fire resistant time for ultra thin steel structure coating is 2.5 hours?
According to the "code for fire protection design of tall buildings", the fire resistance time of the component is at the first level: 3 hours, beam: 2 hours, floor: 1.5 hours;if fire resistance level is level the requirement for time of fire resistance component is the column: 2.5 hours, beam: 1.5 hours, floor: 1 hours. For fire resistant coating, fire resistance time for ultra-thin fire retardant coating is shorter than 1.5 hours. If the time exceeds 1.5 hours, thick fire resistive coating should be used. Steel structure can adopt surrounding concrete or brick, fireproof coating, fireproof board coating and composite structure for its fire resisitance. Fire resisitance board can be divided into thick fire protection plate and thin plate, the thickness of the plate thickness of the fire is between 20 ~ 50mm, mainly includes calcium silicate fireproof board and expansion boring stone fire board, the main varieties are KB board, CF; thin fireproof plate is between 6 ~ 15mm thick, the main varieties include enforced short fiber cement plate, ordinary enforced fiber silicate calcium board and glass cloth reinforced inorganic board. As is known to all, steel structure usually will lose bearing capacity usually in 450 to 650 degree, leading to deformation, steel column and beam bending, and be no longer usable at last. Generally fire resistant limit of unprotected steel stucture is about 15 minutes. 1.5 hours;if fire resistance level is level the requirement for time of fire resistance component is the column: 2.5 hours, beam: 1.5 hours, floor: 1 hours. Steel structure an use surrounding concrete (or masonry), fire retardant coating, fire retardant plate and compround structure to achieve the required refractory limit. Hope my answer will help you.
Q: whether the aluminum silicate thermal insulation material is fireproof or not?
Yes, it is fireproof. Refractory thermal insulation material mainly refers to the inorganic thermal insulation materials and composite thermal insulation materials. According to the shape it can be divided into: Fibrous finishing, mineral?cotton, rock wool, glass wool, aluminum?silicate?wool, ceramic fiber,ect.. it takes the flint clay clinker as raw material, produced by the fusion of resistance or electric arc furnace and the injection of fiber forming. characteristic: Low thermal conductivity, excellent thermal and chemical stability, without binder and corrosive material.
Q: What are the differences between first-level fire-resistant materials and second-level fire-resistant materials?
The combustion performance of materials could be divided into: A( noninflammability), B1(flame retardancy), B2(flammability), B3(inflammability). Building materials are divided into four ranks according to these properties. 1. In accordance with Code for Design of Building Fire Protection(GBJ16-1987)(revised edition in 2001), fire hazards in producing and storage can be divided into five types. In Fire Prevention Code of Petrol Chemical Enterprise Design(GB50160--1992)(revised edition in 1999), classification of fire hazards is also achieved according to the hazards of materials that have been using, producing and storing. Measures in prevention of fire explosion could be taken from the perspectives of fire separation, fire resistance level of structures, allowable floors, safe evacuation, and fire extinguishing facilities based on different levels of fire hazards. 2. Four fire resistance rating of buildings are listed in the book Code for Design of Building Fire Protection. And specific stipulations are made to the fire resistance of main elements of buildings, such as bearing walls, beams,pillars, and floors. When designing a building, if permitted, refractory materials of high-rank should be adopted in those buildings which have high potential fire hazard and a lot of combustible material and valuable equipment. While making sure fire resistance rating, the duration of fire resistance of each elements should meet its requirements.
Q: Who knows the new fireproof and thermal inuslation matertial?
New fireproof and thermal inuslation matertial: foam concrete building blocks brick. The foam concrete building blocks brick is a new fireproof and thermal insulation material, with distinct advantages compared with the organic insulation material . Foam concrete can be used as wall materials, and it has a good self-insulation properties, so there is no problem of dropping off the outer insulating layer. A small part takes external wall exterior insulation, with mostly anchoring or dry hanging, which are not easy to fall off. Very few uses paste. Since the foam concrete and wall materials are of the same nature and strong adhesive, so it is also not easy to fall off.
Q: How many levels are there in the classification of PP fireproof materials?
The level of fireproof materials: A-level: Non-combustible building materials have rare chance to burn. A1-level: Non-combustible materials, no open fire A2-level: Non-combustible materials, smoke should be tested and qualified. B1-level: Fire-retardant building materials: Fire-retardant materials are good at resisting flame. It is difficult for them to burst into fire when coming across open fire in the air or at high temperature. It will not quickly get wilder and when the fire source removes, it will be extinguished immediately. B2-level: Combustible building materials: Combustible building materials can play a certain role in preventing combustion. It will immediately burst into flames when coming across open fire or at high temperature, and will lead to fire spreading, such as wooden pillars, roof frames and beams as well as stairs. B3-level: Inflammable building materials are highly flammable with no flame retardant ability, fire risk is high.
Q: How to divide the fire resistant level of construction thermal insulation materials?
Combining three versions of GB8624 (1997,2006,2011), external wall thermal insulation fire?rating can be basically divided into: A1, A2, B1, B2, B3 and other levels. There are many technical indexes for specific division. And it is mainly determined in accordance with the national standard GB8624 Building materials combustion levels.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords