High Medium Voltage Drive 3KV 2500KW VFD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Energy-saving Solutions for Enterprise
1、Program Overview
◆Saving energy achieves 10% -70%
◆The enterprises do not need to pay for expense of equipment manufacture and installation.
◆Enterprises only need to pay the saving electricity expense to our company according to the actual quantity of energy saving after the equipments put into operation.
◆According thousands of the projects’ implementation experiences, such projects recover the investments in three or four years. (Equipment service life is 15 years)。
◆Our company will no longer charge the saving electricity expense after recovering the investment.
The significance of the program:
1)、Concentrate on solving problems of energy conservation, make enterprises’ energy-saving work reach new level and take their social responsibility。
2)、Avoid the enterprises reactive power fine of low power factor caused by electric energy using (according to Ministry of Electric Power and Water Resources, State Price Control Bureau establish the " measures of power factor adjustment expense ").
3)、Avoid the high-energy consumption enterprises are implemented differential prices because of the changes of national power regulation.
4)、For the standard-conforming large-scale (saved energy equal 10 thousand tons standard coal or more) energy-saving technological transformation projects, China will reward the enterprises for energy saving which based on the "Financial Incentives Interim Measure for Energy-saving Technological Transformations" established by Ministry of Finance, the National Development and Reform Commission.( Amount of 200 yuan / ton of standard coal).
5)、Equipments recovery period is generally 3-4 years, each period payment equal to the amount of current energy-saving benefits, and equipments service life are 15 years, so enterprises will gain huge energy-saving benefits.
2、Implementation Process
Energy Audit
Energy Saving Program Design
Construction Design
Equipments Manufacture
Construction and installation
Maintenance and Repair
Energy Monitoring and Efficiency Insurance
Recovery of Program Investment
3、Program Features
High energy-saving efficiency
The project saving rate is generally 10% -30%, highest is up to 70%.
Clients Zero Investment
All works of design, audit, manufacturing, construction, monitoring are handled by RXPE, clients does not require investment.
Energy-saving Guarantee
RXPE promises the amount of energy saving, ensuring that clients’ cost reduction immediately.
Short Investment Recovery Period
The investment recovery period is short, average period is 3-4 years.
Low Risk
Customers do not input large sums of money also can enjoy professional energy-saving products, technologies and services, and the investment risk is very low.
Improvement of Cash Flow
Customers with the support of RXPE approve energy-saving program to improve cash flow, invest the limited funds into other priority investment areas.
Enhance competitiveness through implementing energy conservation, improving energy-saving efficiency, reducing energy costs and enhancing the quality of environment, establish green corporate image and enhance market competiveness.
- Q: Three-phase asynchronous AC motor speed control method
- Second, the frequency control method Frequency control is to change the frequency of the motor stator power supply, thus changing its synchronous speed control method. Frequency converter system can be divided into AC - DC - AC inverter and AC - AC inverter two categories, most of the current domestic use - cross - frequency converter. Its characteristics: High efficiency, no additional loss during the speed control process; Wide range of applications, can be used for cage type asynchronous motor; Speed ??range, the characteristics of hard, high precision; Complex technology, high cost, maintenance and repair difficult. This method is suitable for applications requiring high precision and better speed performance.
- Q: What is the application of variable frequency speed control?
- Frequency conversion is to change the power supply frequency, thus regulating the load, play a lower power consumption, reduce losses, extend the service life of the role. Frequency translation. Frequency conversion technology is the core of the inverter, through the conversion of the power supply frequency to achieve the motor speed regulation of the automatic adjustment of the 50Hz fixed-line frequency to 30-130 Hz change frequency. At the same time, also make the power supply voltage to adapt to the range of 142-270V, to solve the power grid voltage instability caused by electrical work problems. By changing the AC frequency of the way to achieve the AC control technology is called frequency conversion technology.
- Q: Is the speed of the motor controlled?
- Slip motor is composed of ordinary squirrel cage asynchronous motor, electromagnetic slip clutch and electrical control device composed of three parts. Asynchronous motor, the stepper motor is used as the prime mover, and when it rotates, the armature of the clutch is rotated together. The electric control device is a device that provides the excitation current of the slip clutch excitation coil. Electromagnetic slip clutch, which includes armature, magnetic pole and excitation coil three parts.
- Q: What are the differences and links between the soft starters and the frequency converters, and their respective principles and uses?
- Soft starters and frequency converters are two completely different uses of the product. The frequency converter is used for the need for speed control where the output not only changes the voltage but also changes the frequency; the soft starter is actually a voltage regulator for the motor to start when the output only changes the voltage and does not change the frequency. The frequency converter has all the soft starter functions, but its price is much more expensive than the soft starter, the structure is much more complex. Soft starter (soft starter) is a set of motor soft start, soft stop, light load energy saving and a variety of protection functions in one of the new motor control device, known as the Soft Starter abroad. The softener uses a three-phase anti-parallel thyristor as a voltage regulator, which connects it between the power supply and the motor stator. This circuit, such as three-phase full-bridge rectifier circuit. When using the soft starter to start the motor, the output voltage of the thyristor gradually increases, the motor gradually accelerates until the thyristor is fully conductive, the motor works at the mechanical characteristics of the rated voltage, smooth start, reduce the starting current and avoid starting the overcurrent trip. When the motor reaches the rated speed, the start-up process ends, the soft starter automatically uses the bypass contactor to replace the completed thyristor, providing the rated voltage for the normal operation of the motor to reduce the heat loss of the thyristor and prolong the service life of the soft starter , To improve its efficiency, but also to avoid the harmonic pollution to the grid. Soft starter also provides soft stop function, soft stop and soft start the process of reverse, the voltage gradually reduced, the number of revolutions gradually reduced to zero, to avoid free-wheeling caused by the impact of torque. How the frequency converter works
- Q: Who knows how the frequency converter works
- 3. Control circuit Now the basic converter with 16-bit, 32-bit microcontroller or DSP as the control core, in order to achieve full digital control. The frequency converter is the output voltage and frequency adjustable speed control device. The circuit that provides the control signal is called the main control circuit. The control circuit is composed of the following circuits: "operation circuit" of frequency and voltage, "voltage and current detection circuit" of main circuit, and "speed detection circuit" of motor. The control signal of the operation circuit is sent to the "drive circuit" and the "protection circuit" of the inverter and the motor Inverter to take the control mode, that is, speed control, turn control, PID or other means
- Q: Laptop power adapter output voltage is not the same as the current? What's the effect?
- In the case of other conditions (rated output voltage, plug polarity, etc.) the same circumstances, the rated output current greater power adapter, can replace the rated output current is relatively small power adapter, which is not adversely affected. If the power adapter with a relatively small rated current is used instead of a relatively large power adapter with a rated output current, the power adapter will be "overloaded" and may cause damage to the power adapter.
- Q: 11kw 6-pole motor can be used to adjust the inverter to 1800RPM?
- First, the inverter is no problem, I used so much to meet your needs ????? But to see if your motor can run at high speed, or whether the load is small, the power to have a general amount of redundancy. 6-pole motor synchronous speed of 1000, to meet your use to be transferred between 2000 or 1900, that is to say the frequency converter output frequency to be transferred to 90 to 100HZ. ????? Constant torque load is no problem, but the fan torque load to be a small job.
- Q: What is the adapter?
- An adapter is a physical device that allows a hardware or electronic interface to interface with another hardware or electronic interface (adapt and without any loss).
- Q: Does the inverter set the number of poles to match the number of poles of the motor?
- Variable-frequency (VFD) is the application of frequency conversion technology and microelectronics technology, by changing the motor operating frequency mode to control the AC motor power control equipment. The inverter is mainly composed of rectifier (AC variable DC), filter, inverter (DC variable AC), brake unit, drive unit, detection unit micro-processing unit and so on.
- Q: Three motors, if coupled with the governor speed, is it necessary to add the inverter?
- First, the frequency control: the use of frequency converter to change the frequency of the motor stator power supply, thus changing its synchronous speed control method for all motors, which is the most advanced, the most widely used speed control method.
Send your message to us
High Medium Voltage Drive 3KV 2500KW VFD
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 pc
- Supply Capability:
- 10000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords