Specifications of Patch Panel TIA/EIA
patch panel cat6A/cat6/cat5e/cat3 utp/ftp 24 port/48 port
110/Krone/Dual cat3 cat5e cat6 cat6a patch panel
Meet TIA/EIA-568-A
patch panel cat6A/cat6/cat5e/cat3 utp/ftp 24 port/48 port / 25 port/50 port
110/Krone/Dual cat3 cat5e cat6 cat6a patch panel
Meet TIA/EIA-568-A and TIA/EIA-568-B Category 6 requirements.
Meet TIA/EIA TSB-40
Meet ISO/IEC Generic Cabling Standard 11801
Meet CENELEC Generic Cabling Standard EN50173
Angle: 90 Degree
Termination: 110, KRONE,DUALTypes (3 types)
Electrical Patch Panel TIA/EIA
According to UL 1863
Current rating: 1.5 Amp Max.
Voltage rating: 150 Volts
Contact resistance: 20 m-ohm
Insulation Resistance: 500M-ohm
Dielectric Withstand Voltage: 1000 V AC RMS, 60Hz 1min
Materials of Patch Panel TIA/EIA
Housing: PC UL94V-0
IDC: PC UL94V-0, Accept 22-26 AWG Solid Wire.
PCB: FR4 1.6mm(0.04") thickness, 2 layers
Contact: PC Ul94V-0, 0.45mm(0.018") Diameter Phosphor bronze with 3 u" to 50 u" Gold plating
- Q: Apple phone display cable or accessories not certified how to do
- The control cable transfers the electrical energy from the power distribution point to the power supply lines of the various electrical equipment The rated voltage of the power cable is generally 06 / 1kV and above, the control cable is mainly 450 / 750V The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick
- Q: What machinery is required to make wire and cable?
- Pouring concrete when you can line? Do you clear the problem?
- Q: Remove the computer and wash it off. What the motherboard did not move it, that is, the dust of those dust sasses, as well as the other wire of the skin what Sassafras wash, but the computer re-connected to the Internet when the old mistakes . and the lower right corner of the red Fork appears, disappeared after the emergence. The The Said the network cable is not plugged in, but the MODERN that POWER, LINK, LINE, 3 lights are normal display. The The This is how the matter, and just also appeared keyboard and mouse just start the machine can also be used normally, but in a moment to fall, and then plug their plug re-plug the mouse lights can be displayed, but the lights on the keyboard simply do not Bright, restart the computer but good, what is going on? bother. The The I hope the master quickly to help me, and this machine is relatively old ah No problem added: on a machine, just tried to re-create a connection in the network neighborhood, useless more
- No need. Galvanized flat iron to do when the grounding grid is not anti-corrosion, but if there is welding or damaged place to become anti-corrosion.
- Q: Wire and cable model ZD what does it mean
- Wire pipe water problem: In fact, this problem is very serious, then this line should be scrapped or replaced, if you continue to reluctantly use not only to bring you the safety of trouble and the insulation of the wire dropped sharply! Because there is water it will lead to internal leakage can also make the wire heat caused by wire burning and trivial trivial accident, so be sure to take the necessary replacement! Supplement: the wire out of all, with the wire to grab the absorbent gauze and the like back to the twitching, many times for the gauze to dry the water, hair dryer toward the tube to heat the tube to dry and then re-layout of the new line.
- Q: What are the varieties of wire and cable (detailed point)
- The meaning of the letter: W refers to the halogen-free, D refers to the low smoke, Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant
- Q: Why does the bird stand on the wire without anything, but if people touch it,
- National standard line, no problem. Do not pick up the heater in winter. If not the national standard line, that copper is not easy to go wrong, then use, from time to time touch the line is not hot, there is no problem.
- Q: How are various wire and cable models named?
- Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
- Q: What are the T and T, s of the wire and cable test type?
- May be charging head of the problem, the line may also be a problem. If the warranty can be free for the change.
- Q: Wire and cable fire resistance to meet what standards, which can provide about, thank you!
- Should be the line group: lighting a group of 2.5 square millimeters, an ordinary socket a group of 4 square millimeters, air conditioning a group of 6 square millimeters, kitchen and bathroom appliances a group of 4 square millimeters, so that after the down is not enough to put a separate group You say the high-power electrical outlet, the line to the square of the square mm to see your home how high-power electrical appliances, but advise you to use these high-power electrical appliances before the first to determine its current good, More than your home appliance load!
- Q: What is the warranty period for wire and cable?
- Hello according to your request can be used two sets of ordinary 16 cascade, to a control terminal control 32 hosts. Is the cheapest solution. According to my understanding of the domestic Haikang series of products cost-effective, you can understand the next.
1. Manufacturer Overview
Location | Guangzhou,China |
Year Established | 2009 |
Annual Output Value | Above US$10 Million |
Main Markets | Mid East;Western Europe;North America |
Company Certifications | ISO 9001:2008; |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen |
Export Percentage | 90% |
No.of Employees in Trade Department | 50 People |
Language Spoken: | English;Chinese; |
b) Factory Information | |
Factory Size: | Above 300,000 square meters |
No. of Production Lines | Above 8 |
Contract Manufacturing | OEM Service Offered;Design Service Offered |
Product Price Range | Average |
Send your message to us
Patch Panel TIA/EIA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Piece/Pieces pc
- Supply Capability:
- 10000 Piece/Pieces/week pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches