• Flange End Ball Check Valve System 1
Flange End Ball Check Valve

Flange End Ball Check Valve

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
50 Sets set
Supply Capability:
5000 Sets Per Month set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

‍Packaging & Delivery of Flange End Ball Check Valve

Packaging Details: Inner packing: Plastic package Outer packing: Plywood case, and other packing details as customer's request
 
Delivery Detail: Within 35 days after confirm of order(according order quantity)

 

Specifications of Flange End Ball Check Valve

1.Size:DN40-DN400  

2.Certificate:ISO9001,CE

3.Gurantee:12months

4.Packing:Plywood cases

5.medium:water,petroleum product

 

Ball Check Valve 

 

1.Materials list

Pos.

Description

Materials

1

Valve body

Cast Iron /Ductile iron

2

Valve cover

Cast Iron /Ductile iron

3

Ball

Aluminium + NBR

4

O.Ring

NBR

5

O.Ring

NBR

Screw

Stainless steel A2

Painting epoxy RAL 5017-200µm

2.Applications: Pumping stations for clean, sewage water and loaded or viscous fluids

3.Material Body: Cast Iron GG25, Ductile Iron GGG40, Ball: Steel+NBR/EPDM

4.Technical Data  

Threaded ends from DN25-DN80

Flanged ends from DN40-DN400 

Q: Can the flue check valve and kitchen check valve protect against odor?
Not really. It depends on what valve it is. If it is a variable pressure air valve, of course, if it is an ordinary other valves, generally only temporary role. Five residential home kitchen platoon smoke system is the application of this variable pressure air valve.
Q: The check valve for the printer doesn't have any air in it, but it doesn't come out. It still doesn't work
From your personal statement, analysis of leakage, box of ink cartridges, ink the check valve back looked at the appearance of normal needle, injecting ink into ink box to see, I wish you good luckIn addition, I have not used check valve, the friend that has seen, personal speculation that there is a switch, should be misleading you
Q: What is the difference between the check valve rcvx and SFCV?
3, swing type: liquid in the valve straight through, relying on the pressure to open the side of the rotating valve flap, after the loss of pressure, the valve depends on the weight back, the reverse of the liquid pressure closed valve. Other one-way valves (check valves), such as the sewage check valve, air defense explosion-proof valve and liquid use of the principle of the check valve is very similar.
Q: How much is the 6 point check valve for the water pipe at home?
Different places, different prices, it is estimated that 20-30 copper. Complete check is impossible, and the effect depends on the actual situation,
Q: The principle of the check valve
The check valve can also be used to provide a supply to the auxiliary system where the pressure may rise above the system pressure. The check valve can be mainly divided into swing check valve (rotating by gravity center) and lift check valve (moving along the axis).
Q: What are the differences between the vertical check valve and the horizontal check valve in function and principle?.
The vertical check valve and horizontal check valve are functionally and functionally indistinguishable.The difference between vertical check valve and horizontal check valve:Horizontal check valves, mounted in horizontal pipes, have the same shape as the globe valves; vertical check valves are attached to vertical pipes.Check valve is open and close parts, depending on the flow of medium and power to open or close, to prevent media backflow valve called check valve. The check valve belongs to the automatic valve, mainly used for one-way flow of medium pipe sleep, allowing only medium to flow in one direction, in order to prevent accidents.The check valve is divided into three kinds: lift check valve, swing check valve and butterfly check valve. The lift check valve can be divided into two types: vertical and horizontal. Swing check valve is divided into single, double valve and multi flap type of three. Butterfly check valve for straight through, more than a few kinds of check valve, in the form of connection can be divided into thread connection, flange connection and welding three.
Q: What is the working principle of the flue check valve?
The utility model relates to a flue check valve, which belongs to an automatic valve, and the main function of the utility model is to prevent the backflow of oil smoke, and only to flow in one direction, and to prevent the airflow from flowing in opposite directions.Simon common flue check valve is the use of aerodynamics and mechanical principles of lever machinery, the use of South Korea's imports of high-quality ABS LG engineering materials for the material.
Q: Does the check valve damage affect the flow rate?
Ball check valve will not affect the flow, such as the clip type check valve once damaged, it will affect the flow.
Q: Exhaust hood at home, the wind back, I think it may be smoke hoods mouth check valve blocked, it cleaned it. Then, when the upper air pipe is not installed, the ventilator can work normally, but the air pipe is plugged in and is not ventilated at once. It should be the check valve at the home flue (that is, where the common air duct is attached), but this part of the pipe is inside the kitchen ceiling. Is there a way to repair or clean the check valve without removing the ceiling? If you look for professionals to come home maintenance, how much is the approximate cost?
First, the smoke control valve at the junction of the original building is installed, and this demolition does not have nothing to do with the property.The check valve on the exhaust flue has its function, but also increases the resistance of the exhaust air, and the more the number on the flue, the greater the resistance. And in use, often due to sticky oil fumes, a long time, it will be soiled. So, in the decoration will not be retained in the main flue that check valve, it should be removed, (during the renovation, in the district garbage can be seen everywhere) Only use the machine belt, because its location can be cleaned regularly.Two, according to what your text describes, it should be that the check valve on the main flue is stained. Because in addition to this small piece will cause disruption, there is no other blocking factors. It is unlikely, because the hose folded into 90 degrees into the shed, the naked eye can not see it. But you can use wire to touch it, and if you can push it open, you can try again. However, it is estimated that the shed is still of little significance.The kitchen ceiling is usually plastic buckle or aluminum pinch plate, demolition does not cost anything.It is a reminder: remove the check valve, hose in the crossing installation process should be carefully done, it is best to buy a duct flange, glass sealant with a circle, and then buckle in the flue, the hose into the flange, carefully wrapped with tape, confirmed that no leakage shall prevail this is because, in the shed, and then deal with trouble ah.If the check valve is well connected with the flue port, it is possible to remove the check plate (plate) and make it easier to use the original chassis.
Q: Installation position of air pipe check valve
If you are not in a hurry, leaving QQ, etc. I reply to your husband for this afternoon, he is very professional.
We mainly produce various check valves (for example,single disc swing check valve,double disc swing check valve,ball check valve,lift check valve, butterfly valves,diaphragm valves ,ball valves and so on). Our products are widely used in municipal water and wastewater ,oil,chemical, food and other fields.Our entire valves are designed and manufactured according to ANSI (ASME), DIN, BS, JIS and other standard. Also, we ensure the best quality for customers, and our strict quality assurances systems are conducted throughout the entire production at the standard of ISO9001:2008 and CE.

1. Manufacturer Overview

Location Shandong,China (Mainland)
Year Established 2002
Annual Output Value US$2.5 Million - US$5 Million
Main Markets 40.00% Western Europe
10.00% Mid East
10.00% Southeast Asia
10.00% Africa
10.00% Eastern Asia
5.00% South America
5.00% Eastern Europe
5.00% Northern Europe
2.00% North America
Company Certifications ISOT19001:2000;CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port QingDao
Export Percentage 91% - 100%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 10,000-30,000 square meters
No. of Production Lines 9
Contract Manufacturing OEM Service Offered Design Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords