Technical Date | Material Specification | ||
Nominal Diameter | DN50-DN600 | Valve Body | Ductile Iron QT450-10 |
Nominal Pressure | PN10/PN16 | Hand Wheel | |
Operation Temperature | -40°C~225°C | Bonnet | |
Flange Driling Standard | EN 1002-2 PN10/16 | Gland Flange | |
Suface Treatment | Akzo Nobel Fusion Bonded Epoxy | Stem | 2Cr13/ss410 |
Seal Material | EPDM or NBR | ||
Application |
Portable water, water distribution service & feed lines, sewage disposol, irrigation, fire protection pipe systerm, etc. | Wedge Nut | Carbon Steel |
Thrust Washer | Brass |
- Q: The difference and use of gate valve and stop valve
- Standard light valve professionals to answer for you, gate valve refers to the closure of parts (gate) along the central line of the vertical direction of moving valve. The gate valve is mainly used for cutting in the pipeline. The valve is a valve with a very wide, cutting device general caliber DN = 50mm use it, sometimes a small diameter cutting device also use valve, gate valve has the following advantages:Fluid resistance is small.Minor force needed for opening and closing.
- Q: Z41T one 10 gate valve and Z44T one, 10 gate valve difference
- Z41T one, 10 is single gate, Z44T one, 10 is double gateAccording to the provisions of the JB/T 308-2004 valve type programming method:Z== gate valve4== connection: flange type1== structure: Rigid single gate4== structure: Rigid double gateT== sealing surface material: copper alloy10== pressure rating: 1.0MPa
- Q: What does gate z41t-10 150 mean?
- According to JB/T308-2004 "valve type programming method"Z gate valve4 flange connection1 Ming wedge single gateT sealing cover material is copper alloy10 nominal pressure PN10PN16 below no marked valve body code, body material is gray cast iron150 nominal size DN150
- Q: What are the main types of gate valves?
- According to the different materials for carbon steel valves, forged steel valves, stainless steel valves, cast steel valve, iron gate, ceramic valve;
- Q: What's the difference between open rod gate and dark rod gate valve?
- There are several differences between the open bar gate valve and the dark rod gate valve:1, the bright bar gate valve can see the screw rod, but the dark rod can not see the lead screw;2, clear shot valve is threaded through the drive rod and the steering wheel to raise or lower the valve; dark rod valve in the switch when the steering wheel is connected with the valve stem is relatively fixed, it is through the stem of a fixed point in the rotation to drive the valve to move up and down to complete the opening and closing of the;Drive screw
- Q: What is the difference between Z41X gate valve and Z45X gate valve?
- There is no difference in function. The two models are mainly made of different sealing materials,
- Q: What are the common standards for gate valves?
- 1, product standardsGeneral purpose valves, flanged connections, iron gate valves, GB/T 12232-2005General requirements for steel valves GB/T 12224-2005"Steel flat gate valves for pipelines" JB/T 5298-91Inspection and test of valves. JB/T 9092-1999Standard for safety evaluation of drinking water distribution equipment and protective materials GB/T 17219-1998
- Q: Which is the most expensive, check valve and gate valve?
- In the case of DN50 Z15T-16 DN50: screw valve 46.200 thread copper bar gate valve Z15T-16 DN50 52 Z45F-16 DN50 97 flange valve flange valve rod Z44T-10 DN50 169 Z45T-116 DN50 flange valve dark bar 173 thread swing check valves DN50 52.090 thread straight type check valve DN50 57.280 flange screw check H44T DN50 129 flange valve lift check valve H41T-16 DN50 124
- Q: What is the gate valve for the DN65 hydrant?
- DN150, of course. Ask me about fire protection
- Q: The legend of gate valve and stop valve
- Compared with the cut-off valve, the main advantage is that the flow resistance is small, the flow resistance coefficient of ordinary gate valve is about 0.08~0.12, while the ordinary cut-off valve resistance coefficient is about 3.5~4.5. Opening, closing force is small, the medium can flow in two directions. The disadvantage is that the structure is complex and the height is large. The sealing surface is easy to wear. The sealing surface of the valve must be forced to close the valve to achieve sealing, in the same caliber, work pressure and the same drive device, the drive valve torque is 2.5~3.5 times the gate valve. This point should be noticed when adjusting the torque control mechanism of the electric valve.The sealing surface of the stop valve contacts each other only when the valve is completely closed, and the relative sliding amount between the valve core and the sealing surface is very small, so that the wear of the sealing cover is very small. The sealing surface of the valve cover, mostly due to the spool and sealing surface before the debris, or because of the closed state is not tight, causing the medium of high-speed erosion caused by.
Send your message to us
Flange Gate valve
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
Quality Product, Order Online Tracking, Timely Delivery
OKorder Financial Service
Credit Rating, Credit Services, Credit Purchasing
Similar products
Hot products
Hot Searches
Related keywords