Cable Sleeving
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 3000 Meters watt
- Supply Capability:
- 3000000 Meters per Month watt/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1.Material: polyester (PET) monofil free of hologen
2.Temperature range : -70C ---- 150C
3.Flammability : self-extinguishing according to VW-1
4.Colour : black,grey,white,red,green,blue,yellow,purple,pink,orange,nacarat
5.Melting point 225C~235C
6.ammability : self-extinguishing meets VW-1 of UL
7.pandable sleeving consists of flexible, flame-retardant woven polyester that met
8.braid is able to expand up to 3 times its normal size and isused for bunding and protectiong of electrical cables in power-supply machineand automobile sectors.
9.pproval : CSA,UL,Reach and ROHS, low smoking and self-extinguishing
- Q: District outdoor project using power pipe than the cost of cable trench how much, that is, the cost of electric power cable cable is almost the cost of more than 100 points or so, roughly
- It is not true, because some interfaces can be transferred to each other
- Q: On-site layout, what kind of treatment is to be done when the water supply pipe and the temporary electricity cable are buried together (taking into account the shortest path and cost savings), or how about the construction? More
- Will not step on the bad, stepped on the bad must be fake and shoddy goods. As long as fixed on the line. Do not recommend plaster protection, can not play much use, and it is difficult to find the line to cut off and so on. You have to pay attention to the workers in the shop, when cutting tiles do not cut the line tube.
- Q: Cable transfer box is a trunk for the trunk cable, wiring layer cable to provide fiber optic cable into the end, the transfer of the transfer device. What is the meaning of the end of this sentence? What is the meaning of the end of the cable? (5 points) Please answer in detail. More
- The quality of the wire tube is too bad! Depends on the degree of flat, if not affect the use of no relationship, such as the impact of threading or over the water will use the hammer to cut after the re-open.
- Q: YJV2210KV cable buried when the need to set galvanized pipe? Under what circumstances need to wear galvanized pipe?
- YJV Polyethylene insulated PVC sheathed VV PVC insulated PVC sheathed 4 * 240 + 1 * 120 on behalf of the five conductive wire core, of which four cross-sectional area of 240mm. a cross-sectional area of 120mm2. 1KV indicates that his rated voltage is 0.6 / 1KV
- Q: The vertical clearance between the underground gas pipeline and the water supply pipe drain or other gas pipeline is
- This matter to the professional fire company to do, in order to acceptance
- Q: What is the commonly used communication cable connection casing?
- Need this English in front of the front is the focus
- Q: Building electrical power equipment in the dark pipe is threading or wearing a cable?
- BV denotes a PVC insulated copper wire, and R denotes a plurality of strands.
- Q: How should the pipe remove the debris and water before passing the wire?
- First, the naming of the product is different, the meaning of the difference is different: YJV insulation is the use of cross-linked polyethylene .VV insulation is the use of polyvinyl chloride.Second, the two in the production equipment and process manufacturing are also different: VV Plastic cable, YJV that cross-linked cable, the insulation performance is better than plastic cable. YJV only made a cross-linking treatment on the insulating material to improve the heat-resistant temperature, while VV did not. YJV cable operating temperature of 90 degrees, while the VV is only 70 degrees, with the cross-sectional area YJV cable carrying capacity. VV class cable conductor running the maximum rated temperature of 70 degrees Celsius, short circuit (duration less than 5 seconds) the maximum temperature does not exceed 160 degrees Celsius. YJV class cable conductor running the maximum rated temperature of 90 degrees Celsius, short circuit (duration less than 5 seconds) the maximum temperature does not exceed 250 degrees Celsius. YJV is better than VV in the long run (long life), but more expensive than VV. From the maximum allowable short circuit to see: YJV is 250 degrees, VV is .140. From the technical and economic indicators, the three-core YJV VV cable than the parameters are high. In the civil construction recommended YJV, its carrying capacity than VV large, more important is the electrical fire, because of its insulating material does not contain chlorine, combustion will not produce toxic gases. So that VV environmental performance is poor. In the civilian, nuclear and other fields VV has been basically replaced by YJV, but in many industrial enterprises, VV application is still very wide, because it is cheap. Through the above understanding, I believe we YJV (cable) and VV (cable) have a certain understanding, if they later purchase a similar cable when there will be a more accurate reference.
- Q: Is there a difference between PE cable and PE water supply pipe?
- The above wire structure: conductor + insulation Take 25mm2 as an example: BV is a diameter of 178mm and seven 068 two; BLV is a diameter of 178mmBVR is 19 diameter 041mm; RV copper core PVC insulated soft wire it is more soft than BVR, Or 25 is 49 025mm copper wire; RVV copper core PVC insulated PVC jacket to connect the soft wire than the RV a layer of plastic jacket Another: our most commonly used "jacket line" BVVB copper core poly Ethylene insulated PVC sheathed flat cable is two BV lines, plus a layer of white jacket
- Q: If the title: home cable TV coaxial cable, cable problems, and now want to replace the cable, how to get, have met the same situation friends, to the point of advice! Question added: can be directly through, do not destroy the home decoration? More
- Power cable connection test content: measuring insulation resistance; DC voltage test and leakage current measurement; AC voltage test; measurement of metal shield resistance and electrical resistance ratio; check the cable at both ends of the phase; oil-filled cable insulation Test; cross - connect system test
1. Manufacturer Overview
Location | Guangdong, China |
Year Established | 2004 |
Annual Output Value | Above US$100 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001:2000 ;RoHS;SGS ;CSA |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Cable Sleeving
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 3000 Meters watt
- Supply Capability:
- 3000000 Meters per Month watt/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches