Plyurethane Coated Fiberglass Sleeving 35mm
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2000 Meters watt
- Supply Capability:
- 10000000 Meters per Week watt/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
STRUCTURE
PU glassfiber sleeving is non-alkali glassfiber braided then coated with polyurethane resin and treated by high temperature.
USAGE
PU glassfiber sleeving possesses reliable heat resistance, good qualities of dielectric. It can be used for wiring insulation and mechanic protection for F grade electrical machinery electric appliances
SPECIFICATION
I.D. (mm) | Tolerance (mm) | Thickness(mm) Breakdown voltage 1500V | Thickness(mm) Breakdown voltage 2500V | Thickness(mm) Breakdown voltage 4000V | Thickness(mm) Breakdown voltage 7000V |
0.5 to 3.5 | +0.2-0.1 | 0.38±0.12 | 0.41±0.12 | 0.45±0.15 | 0.52±0.15 |
4.0 to 9.0 | +0.2-0.1 | 0.42±0.15 | 0.46±0.15 | 0.48±0.15 | 0.55±0.15 |
10 to 16 | +0.5-0.1 | 0.50±0.20 | 0.52±0.20 | 0.58±0.20 | 0.65±0.20 |
18 to 35 | +0.7-0.1 | 0.65±0.25 | 0.70±0.25 | 0.75±0.25 | 1.10±0.30 |
- Q: I would like to ask who has the cable trench construction quality acceptance procedures
- These two appliances add up to about 3000W power, it is recommended to use copper wire cross-sectional area of 2.5 square millimeters of wire. In addition, for such high-power electrical equipment, do not recommend the use of the socket, should be directly connected to an air switch, so that meet the safety requirements.
- Q: What are the requirements for the thickness of the protective tube for galvanized steel pipes used for protection of buried cables? What is it? The design is not clear
- HDMI, audio and video HD transmission line, the best choice, now connected to the TV with HDMI cable, can directly transmit audio and video, VGA, then only the transmission of video, but if you are using desktop TV, then, like desktop no HDMI Output interface, you have to connect the VGA cable and then connect the oh oh.
- Q: Cable casing sc65-f / wc is what meaning
- Can be a total of ditch, but there are distance requirements, can not co-management
- Q: On-site layout, what kind of treatment is to be done when the water supply pipe and the temporary electricity cable are buried together (taking into account the shortest path and cost savings), or how about the construction? More
- Will not step on the bad, stepped on the bad must be fake and shoddy goods. As long as fixed on the line. Do not recommend plaster protection, can not play much use, and it is difficult to find the line to cut off and so on. You have to pay attention to the workers in the shop, when cutting tiles do not cut the line tube.
- Q: For example, 4 * 25 + 1 * 16 cable connector used to the above specifications of the material is how much, their own use what? The The More
- Sell pipe where the joints have to sell, a dollar can buy several. Bought directly behind the head of the tube can be, in order to prevent the joints at the spondylolisthesis, can be used after the PVC glue and then inserted into.
- Q: 2 [YJV22-4 * 185] -SC150-FC is the representative of the two YJV22-4 * 185 cable at the same time wear SC150 mean? Or are they wearing two tubes? why? More
- Heat shrink tube and cable support: . the main insulation between the cable core, the exposed wire and the whole set of insulation with the original layer of not less than 20mm, tightened after the outer jacket; . The same with the original outer layer of the intersection of not less than 20mm, if possible where the moisture immersion, the intersection needs to be coated (heat shrink tubing) sealant. Heat shrink tubing and cable supporting the use of specifications:
- Q: Cable protection tube where the need to play a trumpet what role
- Is not a zero line is not a ah. Three zero lines.
- Q: What are the environmental factors and hazards in the construction of cable
- It is best not to pick their own, easy to virtual connection, there can be soldering iron can also be welded, not for a new bar
- Q: Ask you a question, the basement has a power distribution room, high pressure into the wall in the shear wall to stay a few walls through the wall, asked, after the cable through the casing, the cable and how to do between the waterproof treatment? Because now rain, rain water along the casing to the basement irrigation. In the underground garage outside the wall to do a well, the casing around, but still not, because the rain, the wells will be water, the same to the basement irrigation, this place generally how to deal with, it is best to give What is the explanation of what more
- Digital TV signals are packaged to send, and the frequency of each package is not the same
- Q: On the cable cross-sectional area, I would like to ask 3 * 10 +2 * 6 under the cable casing, casing to thick, the best formula
- Wire is required to multiply the number of roots, such as: BV-3 * 2.5 its volume is BV-2.5 single length * 3; cable is not multiplied by the root floor, calculated by the core, such as: YJV-4 * 25 + How long is it long?
1. Manufacturer Overview
Location | Guangdong,China |
Year Established | 2008 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 12.50% North America 12.50% South America 12.50% Eastern Europe 12.50% Southeast Asia 12.50% Oceania 12.50% Western Europe 12.50% Northern Europe 12.50% Southern Europe |
Company Certifications | ISO9001:2008;RoHs;CSA Certificate UZFT8 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shenzhen,Guangzhou,Hongkong |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 10,000-30,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Average |
Send your message to us
Plyurethane Coated Fiberglass Sleeving 35mm
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 2000 Meters watt
- Supply Capability:
- 10000000 Meters per Week watt/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches