Brushless Diaphragm Water Pump
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications:
Perfect for caravans, boats, motorbikes, trucks and camping. Use it with fresh or salt water with your deck wash or to run your toilet or shower. These pumps automatically turn themselves on and off when you turn the tap on and off. Comes with filter and fittings. These pump are for intermittent use only.
A great pump for those country folk, with a small family, on tank water who only need to boost the pressure from a tank next to the house.
We have tested these pumps and found they will operate to a 2 metre suction lift and 5 metre head with no problems.
1.Maximum torque and operating efficiency/higher operating pressure and/or lower amperage than competitive pumps
2.Long life, no leaks, strong corrosion resistant
3.12/24 VDC and 115/220 VAC motors standard (consult factory for other voltages)
4.Quality components for extreme performance
5.Numerous fitting options for greater mounting flexibility
6.Voltage:12V/24V DC Diaphragm Pump,115V/230V AC Diaphragm pump
7. Expecially suitable for marine and recreation vehicle, such as boat and ship.Also suitable for Agriculture sprayer
Features
Lightweight and made from non corroding materials
Self priming
Run dry Protection
Easy to install
No maintenance
Simple to operate
Low power consumption
12 months warranty
Automatically turns on and off
Comes with filter and fittings
How a Pump Works
The pump is driven by an AC or DC motor
In front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled hrough the inlet, through the various valve chamber check valves to the outlet he volume of flow is determined by several factors including: the number and size of the pump chambers,cam offset, operating pressure, fluid viscosity.
- Q: Know flow and lift how to calculate the pump power?
- The pump power (kw) ={9.61* flow (cubic meters per second) * head (m)}/.Where ETA is device efficiency, including mechanical, electrical loss and other factors, generally between 55%~80%. The smaller the pump, the lower the efficiency.
- Q: Fire pump and shower pump flow head selection, high resolution.
- Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
- Q: Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
- 1) oil rotary vane vacuum pump is too low, no effect on the oil seal exhaust valve, rotary plug to refuel after large exhaust sound, and oil mist, that the level is too low, the gas can be eliminated.(2) the vacuum caused by the condensable steam pollution of oil should be changed, and new vacuum pump oil should be replaced.
- Q: Water pump outlet valve sequence
- To reduce the impact of vibration, noise and vibration on the valve, the soft connection is best at the pump outlet.The check valve is sometimes checked, so it is placed in front of the outlet valve so that the water can be checked out. I think the order should be: pump outlet, soft connection, check valve, gate valve (butterfly valve)
- Q: I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
- Constant pressure pump is pressure maintained at the set pressure, flow control valve according to the order, there is pressure to set, after the pump displacement is reduced, as for how to reduce emissions, to see how much you need to flow.
- Q: How to install, operate and maintain the pipeline booster pump?
- The motor coil is provided with a safety protector, and when the pump is out of order or the water is not pumped, the motor can automatically break down when the temperature of the motor exceeds the prescribed value, and the motor can automatically resume operation after the temperature rise of the motor is decreased. The booster pump motor is a capacitor running type motor. When the pump leaves the factory, the rotation direction has been adjusted. If you need to replace the capacitor or re connect, press the arrow direction on the pump body to mark the connection. To ensure safety, use the three - core safety socket with ground wire.
- Q: What are the starting and stopping procedures for centrifugal pumps?
- The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
- Q: Advantages and disadvantages of centrifugal pumps?
- Centrifugal pump; advantages and disadvantages:(1) advantages:The structure of the pump is simple and compact, and the centrifugal pump has small area, light weight, little material consumption and high cost for the foundation. Therefore, the cost of manufacturing and installation is less.For high speed operation, the 2 pole or 4 pole motor can be directly connected. The drive structure is simple and easy to install.
- Q: What is the pumping property of concrete?
- Pumping capacity means that fresh concrete can be transported by concrete pump, and concrete construction can be carried out with high efficiency. 'pumping' is a qualitative statement
- Q: Attention should be paid to the use of pumps?
- 1, pump shaft packing completely worn, it is necessary to add in time, if you continue to use the water pump will leak. The direct effect of this is the increased energy consumption of the motor, which will damage the impeller. 2, the use of pumps in the course of a strong vibration, then must stop to check the reasons, or the same will cause damage to the water pump. 3 gear pump valve Water Leakage, some will use the soil into the water pump inlet tube, the water washed in the end valve, this is indeed undesirable. Because when the dry soil into the inlet pipe, when the pump started working, these dry soil will enter the pump, which will damage the pump impeller and bearings, which shorten the service life of the pump. When the valve Water Leakage must take to repair, if it is serious that it is necessary to replace the new. 4 after the use of pumps must pay attention to maintenance, for example, when the pump is exhausted, we should put the water pump who put clean, it is best to remove the water pipe, and then rinse with water. 5 water pump on the tape should also be written down, and then always flush, and then light out to dry, do not put the tape in the dark damp place. Water pump tape must not be stained with oil, not to tape coated with some sticky things.