Automatic Door Glass Sliding :

Smart Automatic Door
(1)ISO 9001 & CE Certified
(2)Silent working
(3)Modularization design
(4)Easy to install and adjust

Technical Specification

Parameter

ES-90/SOGD-100

ES-100/SOGD-150

Range of the Door

Single-leaf

Double-leaf

Single-leaf

Double-leaf

Door Leaf max Weight

90kg

90kg x 2

120kg

120kg x 2

Door Width

700-1300mm

650-1050mm

750-1600mm

650-1250mm

Installation Type

Surface Mounting

Max Door Leaf Thickness

50mm

Motor

DC24V, 65W

Power Supply

AC220±10%, 50-60 Hz

Input Current (Standby)

0.095A

Input Current(Operation)

1.6A

Opening Speed

250-550mm/s (adjustable)

Closing Speed

250-550mm/s (adjustable)

Creep Speed

30-100mm/s (adjustable)

Hold-open Time

2-20s (adjustable)

Hold-Close Force

70N<f<220N

Manual Pushing Force

<50N

<60N

Power Consumption

<150W

Ambient Temperature

-20+50 °C

Functional features:

(1)Exists in double and single sliding versions;

(2)Powerful and full functions: offer our users 4 operating options of full automatic,half open, constant open and constant lock;

(3)Flexibility:allows tempered glass door leaves as well as 50mm thickness wooden door leaves;

(4)Reliability:built-in microprocessor ensures the accuracy and precision of the operation;

(5)Safety:the door leaf(ves) will go backward when people or moving obstacles approach while closing,which prevents the clamp injury and damage of the door itself.

(6)The door leaf(ves) could be deftly manually opened at a power failure;

(7)Modularization design allows a simple and easy installation;

(8)Purpose made polyurethane covered silent wheels realize quiet operations;

(9)Multiple optional access method:

a.Sensors: microwave sensor,feet sensor;

b.Password:password or finger print identification access;

c.Card:IC card,RFIC card;

d.Button:Elbow touch,feet touch and long-distance buttons.





Q: The recent incidents involving severe fires on TX4s raise questions about automatic door-locking on London black cabs. If I understand correctly, the doors automatically lock when the driver uses the accelerator and unlock when the brake is applied. Since unlocking the doors requires action by the driver, doesn't this put the passenger at risk in such emergencies ? I know that the The recent incidents involving severe fires on TX4s raises questions about automatic door-locking on London black cabs. If I understand correctly, the doors automatically lock when the driver uses the accelerator and unlock when the brake is applied. Since unlocking the doors requires action by the driver, doesn't this put the passenger at risk in such emergencies ? I know that TX4s have been taken out of service but the dangers of automatic door-locking still apply.
Door Locks London
Q: My '05 Mustang is cycling the automatic door locks while I'm driving!!? This just started and it seems like it
Why the hell did you buy a mustang in the first place! 69 Mustang i can understand but 05 Mustang is a pile of shite and does not go around corners. Trade it in and get an old one, Go on you know it makes sense!
Q: How did the power off the power off?
In fact, the common electric door generally have two! One is the electric sensor door (sub-open and translational type), this door after the power outage only need to push to open! There is also a curtain, electric device at the top of the door, usually after the decoration is invisible, only one chain outside the ceiling. After the power outage need to manually move in a direction to slowly open the chain! The The Not common in the use of financial units, with access control. Need to password or fingerprint identification system to open, power outages are generally open, unless it is to use high-tech crack or man-made damage Caixing!
Q: I have power, it worked once this morning and I do hear a humming noise,but,the MOTOR sounds like it's not activating itself, again,there is a humming noise,hence, the circuit board appears to be getting the message to close door,however,it's not.Could it be a burnt motor or circuit board issue?.Thank you folks...
well these days systems have a lot of safety features . check the door its self some doors stop operating if it thinks some thing is under it so you may have to adjust it by putting a 2x4 under it than playing with the adjustment then it could be the sensors on both sides at the bottom of the door examine them closely if they have led's on them then wave your hand pass them to see if they are operating properly PS: check all the fail safes first than ask your next question
Q: Forced open while in drive, and it is not coming unlocked to open. Sounds like it is going to open but it can't because we can't get it unlocked. Is there a way to unlock it or release the lock button?
It's jammed, try pushing the door from the outside towards the close position even further, then while holding it in that position try putting it into neutral and open the door while releasing it from the outside at the same time. If no click click is heard, then it must have to go the the dealer.
Q: what does it mean when a pilot says to the flight attendant &amp;quot;cabin crew side doors automatic&amp;quot;?
When selector placed to automatic, if doors are open, evacuation slides would deploy - If selector in manual, evacuation slides do not deploy if door is opened - Doors must be in manual to permit normal door opening at airports - Doors are placed in automatic when taxiing for takeoff, until arrival after landing - Generally that command is not given by a pilot, but the senior flight attendant - Upon arrival after landing, command will be cabin door selector in manual -
Q: Can the fire door be replaced by an electric door?
Need to fire department approval, shall not arbitrarily change and move the fire facilities
Q: Electric revolving door has been kept non-stop why?
Usually the probe has a sensor swivel, stop switch failed to normal transmission of the signal, in question, plus my network name number, detailed to you
Q: Can the electric door be turned on by hand?
Common electric doors generally have two! One is the electric sensor door (sub-open and translational type), this door after the power outage only need to push to open! There is also a curtain, electric device at the top of the door, usually after the decoration is invisible, only one chain outside the ceiling. After the power outage need to manually move in a direction to slowly open the chain! The The Not common in the use of financial units, with access control. Need to password or fingerprint identification system to open, power outages are generally open, unless it is to use high-tech crack or man-made damage Caixing! Do not ask friends to personally try yo! The The
Q: History of revolving doors
In the 1940s, the revolving door increased the speed control, allowing the door speed to be controlled as required. With the development of automation and automation, various automatic door revolving doors, revolving gates with card reader to identify safety performance, automatic doors with various safety protection sensors, and many special purpose revolving doors are added to the original manual four wing doors Series, so that its continuous development, only the automatic revolving door. The development of automatic doors is not only due to its anti-noise and dustproof performance, it is important to point to its energy-saving features, the American Institute of Heating, Refrigeration and Air Conditioning Engineers conducted in the United States to obtain the conclusion that the revolving door entrance is the most economical Effective building entrance. With a common diameter of 2m, 2.1m high revolving door, each pass only when driving 1.7 cubic meters of air circulation. Due to the small amount of heat exchanged in the air, the energy efficiency of the revolving door is very good.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords