Aluminum Flexible Duct Insulated for HVAC
1.Structure of Aluminum Flexible Duct Insulated for HVAC:
Flexible air ducts are typically made of flexible plastic over a metal wire coil to shape a tube. And they have a variety of configurations. Flexible ducts are very convenient for attaching air outlets to the rigid ductwork. It is commonly attached with long zip ties or metal band claps. Besides, flexible ducts can tolerate moderate negative pressures.
2.Main Features of Aluminum Flexible Duct Insulated for HVAC:
-Applied in air conditioning/ventilation systems
-Tear and puncture resistant
-Corrosion resistant
-High flexibility
-Convenient installation
-No toxic gas emission
3. Aluminum Flexible Duct Insulated for HVAC Images
4. Aluminum Flexible Duct Insulated for HVACSpecification
Insulated Flexible Duct
Structure: 1 layer of Aluminum Foil+1 layer PET film+insulated glass wool
Outer jacket: 1 layer of Aluminum Foil
Glass Wool Density: 16kg/m3; Thickness: 25mm
Insulated Acoustic Flexible Duct
Structure: 1 layer of Aluminum Foil +1 layer PET film+ insulated glass wool
Outer jacket: 1 layer of Aluminum Foil + 1 layer of PET film
Glass Wool Density: 32kg/m3; Thickness: 25mm
Specification
Type 1
Material | Aluminum foil |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. |
Application | Suitable for medium-low air speed |
Technical Parameter
Size | 4”-16” |
Standard Length | 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 2
Material | Aluminum foil 25mm thickness ,16kg/m3 glass wool. |
Structure | Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. Insulating layer is covered by 25mm thickness ,16kg/m3 glass wool. Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and low temperature difference. |
Technical Parameter
Size | 4”-5”, 6”-12”, 14”-16” |
Standard Length | 7m, 10m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
Type 3
Material | ·Aluminum foil · 25mm thickness ,24kg/m3 glass wool. |
Structure | · Inner pipe is made of aluminum foil and inside spiral structure is hold by high tensile steel wire. · Insulating layer is covered by 25mm thickness ,24kg/m3 glass wool. · Outside layer: Reinforced aluminum foil; Inside layer: Glass fiber mesh |
Application | Suitable for medium-low air speed and large temperature difference. |
Technical Parameter
Size | 6”-12” |
Standard Length | 7m |
Maximum Air Speed | 20m/s |
Maximum Heat Resistance | -20℃-150℃ |
Maximum Pressure | 250mmWG |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
1.How long for the delivery time?
Delivery time: 10-30 days, it depends on the ordered quantity.
2.What’s the usage?
Practicality: suitable for the densely-populated area(such as school, supermarket, office, stadium, theater, factory.),high requirement of the environment area, such as hospital, laboratory, howff, bus, train, broadcasting studio. main usage: 1) Cold, hot water supply facilities for public buildings 2) Food, chemical, electronic industrial pipeline networks such as pipeline networks for transporting all kinds of corrosive liquid 3) Drinking water production system pipeline networks such as pure water and mineral water 4) Air conditioning facility pipeline 5) Compressed gas pipeline networks for industry 6) Pipeline network for swimming pool 7) Pipeline network for solar energy facility 8) Agriculture and garden production Additional information
③How you control the quality?
During the production of fiberglass insulation, material is sampled at a number of locations in the process to maintain quality.
- Q: Air to water heater host and air conditioning host is not the same
- This test with a small sample length 127mm, width 12.7mm, the maximum thickness of 3.2mm. In the absence of ventilation test chamber. The top of the specimen (6.4 mm place) is clamped with a clamp on the bracket and the longitudinal axis of the specimen is kept vertical. The lower end of the specimen is 9.5mm from the lamp tip and 305mm from the dry absorbent cotton surface. Bring the Bunsen burner and adjust it to produce a blue flame with a height of 19mm. Place the Bunsen Lights flame at the bottom of the sample for 10s, then remove the flame (at least 152mm away from the specimen) and write down the sample. Burning time. If the flame of the sample within 30s after removal of the flame is extinguished, the original lamp must be moved under the specimen again, re-ignite the sample for 10s, and then remove the Bunsen burner again and note the flame burning And flames burning the burning time. If the sample droplets drip, let it fall into the sample under the 305mm cotton, to see whether it ignited cotton. If the absorbent cotton is on fire, the rating should be taken into account. Specific grading indicators are as follows. Test Item 94V-094V-194V-21 Ten-time ignition Total flame burning time Maximum value (S) Individual flame burning time Maximum value (s) Flameless burning time (s) Yes Flame drop No No Allow only short time Burning general UL yellow card on the thickness of the test strip is divided into: 1/8 inch, 1/16 inch, 1/32 inch thickness, that is, 3.2mm, 1.6mm, 0.8mm three grades test.
- Q: Air conditioning ventilation when the sound is a big reason
- Buried plastic pipe under external load, the diameter of the vertical diameter deformation rate should be less than the allowable diameter of the pipe deformation rate The diameter of the allowable diameter of the pipe shall not be greater than 5% The diameter deformation rate of the pipe and the allowable diameter deformation rate are calculated as follows: ε ΔD / D0 × 100% [ε] ε0 / K where: εΔD pipe in the combined load (Mm) [ε] Permissible diameter Deformation rate ε0 Elastic diameter Deformation rate (%) of pipe, by the flattening of the diameter of the pipe diameter (mm) The test determines the K safety factor, generally desirable 15
- Q: US direct mail dysonhp01 Dyson air purification cooling machine triple in the country to warranty it
- Among them, the extruded polystyrene gypsum composite board is based on paper gypsum substrate, the use of adhesive and extruded polystyrene board through the factory processing compound
- Q: Gree air conditioning 50 heating and cooling mechanism heat when the host cooling network is how the matter
- Not the ,,, mobile air conditioning inside the compressor, the winter heating also need the compressor, but also a ventilation pipe, charged heating Well?
- Q: I added the space 18 degrees opened for 5 hours or not cold, we all know how is it? More
- The general level of more than 12 layers when you need to use.
- Q: Air conditioning machine work when the sound is too much reason
- Color steel plate, refers to the color coated steel plate, color coated steel plate is a kind of organic coating with steel plate
- Q: What is the whole heat exchange fresh air ventilator?
- Second, the new insulation decorative board is integrated through the production line, set insulation, waterproof, finishes and other functions in one, is to meet the current housing construction energy needs, improve the industrial and civil building exterior wall insulation level of the preferred material, but also on the existing Building energy-saving transformation of the preferred materials
- Q: External wall insulation method of operation There are several combinations of materials
- 30-150 per square meter has, mainly to see the material, thickness and so on
- Q: Ventilation is very good, why still have to install fresh air system
- You are a single raft toilet wipes Pie Tanzhuang open card would like to confirm what? Contract notarization or. The The If it is contract notarized, generally notary value of 0.25% -0.3%
- Q: HVAC Heating: What are the main components of the air distribution system?
- Geothermal construction, the heating pipe spacing can not be less than 100mm, the construction can not be achieved, big brother!