1. White Fused Alumnina Tech Data:
Model: WFA 0-1mm
| ||||
Chemical compositions | Physical properties | |||
Items | Value of specification (%) | Items | Property | |
Al2O3 | 99.6min | Color | White | |
SiO2 | 0.02max | Bulk density | 1.75-1.95g/cm3 | |
Na2O | 0.25max | Grain density | 3.90g/cm3 min | |
Fe2O3 | 0.03max |
hardness | Morse hardness | 9 |
Micro hardness | 21600-22600kg/mm3 | |||
Usage | Refractory | content of magnetic substance | 0.0023%max |
2. White Fused Alumina Refractory sizes:
Grain size : 8-5mm, 5-3mm, 3-1mm, 1-0mm
-8+5mm,-5+3mm,-3+1mm,-1+0mm
8-16,16-30,30-60,60-80
-8/+16, -16/+30, -30/+60, -30/+60
Fine powder: -320mesh, -280mesh, -240mesh, -200mesh,
-180mesh, -150mesh, -120mesh, -100mesh
320F 280F 240F 200F 180F 150F 100F
3. Delivery and Package:
According to customer's requirement.
4. Advantages :
Good quality
Delivery on time
Resonable price
Good service
Pcture
- Q: Who knows the setting requirements of roofing fire barrier zone?
- First, the the minimum of fire barrier width is greater than 30cm, and the thickness should be same to the thickness of the insulation materials. Fire barrier zone insulation board must do the whole area sticking construction with the base wall during the construction. Fire barrier zone insulation board is required to assistant binding by anchor bolt, anchor bolt must suppress the underlying mesh. Second, Fire barrier zone should be set at the upper position of door and window openings, the distance between the low edge of isolation belt and the upper edge of the window must be less than 50cm. The thermal resistance of fire barrier zone must be half than EIFS thermal resistance in the cold northern areas, while the thermal resistance of fire barrier zone must be three times than EIFS thermal resistance in the hot summer and cold winter area. Third, When the fire barrier zone is set on the edge of the window, fire barrier zone at the upper part of the window should do flanging when sticking, flanging glass fiber mesh must exceed 10CM than firebreak insulation board. Flanging network, underlying network and surface network can not be overlapped or butted at the top of the window. I hope you can be satisfied
- Q: The mechanism and function of antioxidants in carbon containing composite refractories are briefly described.
- 3, the selection principle of antioxidant and its thermodynamic and kinetic mechanism31 selection principles of antioxidants:(1) according to the thermodynamic data and the conditions of use, the possible condensed phase and the vapor pressure of each gas phase are determined;(2) compare the size of each coacervation and oxygen affinity, and the possibility of reaction with CO.(3) the influence of various reactions on the microstructure of brick was analyzed.The thermodynamic and kinetic mechanism of 3.2 antioxidantsFrom a thermodynamic point of view, at the operating temperature, the additives or additives that react with carbon react with oxygen more closely than carbon and oxygen, giving priority to carbon oxidation, thus protecting carbon;From the analysis of dynamics point of view: the compound additive with oxygen and carbon monoxide reaction changed the microstructure of carbon composite refractory materials, such as increasing the density, blocked pores, hinder the diffusion of oxygen and reaction products.
- Q: How to determine the fire resistance rating of the aluminium-plastic?panel?
- Class A incombustible and thermal insulation material: inorganic active wall thermal insulation material, cement foam insulation board, glass bead thermal mortar, rock wool board, glass wool board, foam ceramics, etc. With many characteristics of low density, low thermal conductivity, high pressure bearing capacity, convenience of construction, economy and durability, A class incombustible material is widely used as thermal insulation material for heat pipelines, thermal equipment, other industrial pipe-line equipment and industrial buildings, and thermal insualtion and sound absorption material for the building envelop of industrial and civil buildings. Because of good thermal stability, it is more often used as fire-proof and protective coating material of the steel structure.
- Q: Who knows about the grade C fireproof door materials?
- Wood or steel materials are usually used in them. The new national standard fire doors: According to the enacted GB12955-2008, the fire endurance of grade C fire doors is 0.5 hours and that of grade A and B are 1.5 hours and 1.0 hours respectively.
- Q: What are the types of refractory sealant?
- Refractory sealant has low exothermicity and will form a hard corking content during burning, it includes: Liquid polysiloxane has at least two active groups selected from alkoxy, hydroxy and alkenyl; a cross-linking agent, a catalyst, a reinforcing filler and wollastonite. These cured silicone rubber sealant has low heat release and will form a hard coking content structure while buring. Refractory sealant composition can be used in sealing structure to prevent flames, air and other steams passing. 1. In a liquid organic polysiloxane polymeters, each R1 is independently selected from the alkyl, aryl, alkenyl and haloalky which has 1-18 carbon atoms, and each R2 is independently selected from the hydroxy, alkoxy, alkenyl, and X is an integer from about 10 to 1,500. 2. A crosslinking silicone compound having at least 3 silicon-bonded eactive groups. 3. A R2 pressed of silicon bonding capable of promoting component A. 4. Wollastonite and a selective reinforcing filler.
- Q: Does anyone know what is the use of waste refractory materials?
- Waste refractory materials can be 1, Recycled to do the aggregate and powder of castable , or make bricks. 2, can be reused after smash.3, Metal silicon is an anti oxidant in refractory material, mainly functioning as he oxidation resistance, at the same time improve its toughness.
- Q: what is the specs of thermal insulation refractory slab ?
- According to different requirements of each project to select the fire board. fireproof?panel should have product qualification certificate. Specifications shall comply with the requirements of design drawings and inspection reports from the National Fireproofing Protection Building Materials Inspection Center. General specifications are as follows: Length: it is determined according to the project width: 1200mm, 900mm; thickness: 9.5mm, 12mm, 15mm, 18mm, 25mm. Commonly used is 12mm. According to different requirements of each project to select the fire board. Fireproof?panel should have product qualification certificate. Specifications shall comply with the requirements of design drawings and inspection reports from the National Fireproofing Protection Building Materials Inspection Center. General specifications are as follows: Length: It is determined according to the project width: 1200mm, 900mm; thickness: 9.5mm, 12mm, 15mm, 18mm, 25mm. Commonly used is 12mm.
- Q: How to make the service life of refractory materials longer?
- Take acid resistant refractory materials as example: the atmosphere should be acidic atmosphere, if used in an environment whose temperature is 1900℃, it would exacerbate the loss of refractory materials, so don’t use overloaded. Second, select the appropriate refractory materials according to the environment. For example, if its operating temperature is 1800℃, generally speaking, the normal use of it according to the instruction of refractory materials would be fine.
- Q: How to distinguish the fire resistant level of construction materials?
- Division of fire resistant level of building material: 1, It can be divided into five levels according to the importance: a, special class: commerative, historic, international and national buildings. b, Class A: high-grade residential architecture and public building. c, class B: middle-grade residential architecture and public building. d, class C: orinary residential architecture and public building. 2, It can be divided into four grades according to fireproof?performance: Fire resistance level buildings is divided into four levels. Standard of fire resistant level is based on the combustion performance and fire endurance of main components of the house. 3, It can be divided into 4 levels according to durable life: a, A grade durable life, over 100 years, for important buildings and high-rise buildings. b, second level durable life, from 50 to 100 years, for ordinary buildings. c, third level durable life, from 25 to 50 years, for secondary buildings. D, fourth level durable life, less than15 years , for temporary buildings. I hope my answers will help you.
Send your message to us
Raw Materials for Refractory:White Fused Alumina Good Quality Made in China
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 200 m.t.
- Supply Capability:
- 20000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords