• Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 1
  • Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 2
  • Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 3
Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH

Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 SET
Supply Capability:
1000000 SET/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH


1.Lithium iron Phosphate battery Proven track record

2.System charging and discharging efficiency>90%

3.The battery cycle life under energy storage conditions exceeds 6000 cycle

4.Integrate high-speed communication, power distribution and metering, AC output adopts 2-level controllable switch + passive protection

5.Adopt high-current high-efficiency two-way active equalization technology to eliminate series losses caused by inconsistent batteries

6.Modular design, indoor or outdoor, space efficient




  • Product Description

  • CFE main technical indicators

    Serial number

    Index


    System nominal

    Rated power

    500KW

    1000 KW

    1000 KW

    Nominal    capacity

    2580KWh

    3010 KWh

    3440 KWh


    Communication side

    Rated voltage

    380V

    380V

    380V

    Rated current

    759A

    1500A

    1500A

    Rated    frequency

    50HZ

    50HZ

    50HZ

    Power factor

    >0.98

    >0.98

    >0.98

    Wiring

    Three-phase    three-wire

    Three-phase    three-wire

    Three-phase    three-wire

    Isolation    transformer

    630KVA

    1250KVA

    1250KVA

    Inrush    current

    Less than 7 times Ie

    Harmonic    distortion rate

    Less than 3% (secondary    side of transformer)


    DC side

    Rated voltage

    768V

    768V

    768V

    Lower limit    voltage

    600V

    600V

    600V

    Upper limit    voltage

    876V

    876V

    876V

    Rated current

    650A

    1300A

    1300A

    Cell    specifications

    280Ah

    280Ah

    280Ah

    Number of    batteries

    2880

    3360

    3840

    Number of    modules

    180

    210

    240

    Module    specifications

    1P16S

    1P16S

    1P16S

    Actual    capacity

    2580KWh

    3010KWh

    3440KWh


    Battery management

    Cluster    battery

    12

    14

    16

    Cluster unit

    12

    14

    16

    Voltage    accuracy

    0.002

    0.002

    0.002

    Temperature    accuracy

    0.01

    0.01

    0.01

    SOC accuracy

    0.05

    0.05

    0.05

    Power    accuracy

    0.01

    0.01

    0.01


    Cabinet

    Battery    cabinet

    966*855*2400mm

    966*855*2156mm

    966*855*2156mm

    Control    cabinet

    2000*600*700mm

    2000*600*700mm

    2000*600*700mm

    PCS cabinet

    1400*825*2180mm

    1400*825*2180mm

    1400*825*2180mm


    Air conditioning

    Installation    method

    Embedded

    Embedded

    Embedded

    Cold power

    30KW

    30KW

    30KW


    Fire control

    Fire fighting    medium

    Heptafluoropropane

    Spray method

    Pipeline (battery room)


    Fire detection tube (PCS    room)


    Communication Interface

    Wireless

    2G,1 minute update

    Wired

    Network, 5 seconds update

    System cycle    life

    >6000Cycle(25℃)

    >6000Cycle(25℃)

    >6000Cycle(25℃)

    Capacity    availability

    >80%

    >80%

    >80%

    Weight

    <20T

    <41T

    <45T

    Structure    size

    12.192m*2.438m*2.591m

    12.192m*2.438m*2.591m

    12.192m*2.438m*2.591m



FAQ

CFE Lithium-ion Battery




Q: What kind of battery you can provide?

A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.

    b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).

    c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.

    d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.

    e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).

    f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.


Q: What is the capacity of production?

A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.


Q:How long is the warranty period?

A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.


Q: How long is the estimated delivery time?

A: The delivery time is within 25 days after receiving the payment.


Q: Are you able to handle shipment transportation?

A: We can arrange the shipment to most places as required.


Q: What kind of certification do you have?

A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.


Q: What kind of product quality your factory offer?

A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .


Q: Can we print our logo on products?

A: We can provide one to one customized OEM with a MOQ demand.


Q: What is the validity of the quotation?

A: Due to the raw material price fluctuation, the quotation validity is 10 days.


Q: How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q: How is the capacity of the battery defined?
The capacity of the battery unit is AH (safety) is the product of current and time.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: How to deal with waste batteries?
The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
Q: What are the hazards of battery over discharge?
When the battery discharge current is large, the heat will become more obvious, there will be serious heat generated when the battery deformation, when the concentration of lead sulfate is particularly large, will form a larger crystal particles, that lead to the battery Internal irreversible sulfation.
Q: Maintenance-free battery how to detect it?
When using a maintenance-free battery, it is easy to think that maintenance-free is the idea that no maintenance is required. Maintenance-free Although maintenance costs and times can be reduced, but for the appearance of the clean-up is essential, so that "maintenance-free" more point to the battery inside.
Q: What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q: How does the battery increase the voltage?
You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
Q: What is a maintenanceable battery?
It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Q: Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords