• Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 1
  • Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 2
  • Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH System 3
Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH

Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 SET
Supply Capability:
1000000 SET/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Utility ESS Lithium-ion LFP Battery Container Energy Storage System 2.58/3.01/3.44MWH Customized MWH


1.Lithium iron Phosphate battery Proven track record

2.System charging and discharging efficiency>90%

3.The battery cycle life under energy storage conditions exceeds 6000 cycle

4.Integrate high-speed communication, power distribution and metering, AC output adopts 2-level controllable switch + passive protection

5.Adopt high-current high-efficiency two-way active equalization technology to eliminate series losses caused by inconsistent batteries

6.Modular design, indoor or outdoor, space efficient




  • Product Description

  • CFE main technical indicators

    Serial number

    Index


    System nominal

    Rated power

    500KW

    1000 KW

    1000 KW

    Nominal    capacity

    2580KWh

    3010 KWh

    3440 KWh


    Communication side

    Rated voltage

    380V

    380V

    380V

    Rated current

    759A

    1500A

    1500A

    Rated    frequency

    50HZ

    50HZ

    50HZ

    Power factor

    >0.98

    >0.98

    >0.98

    Wiring

    Three-phase    three-wire

    Three-phase    three-wire

    Three-phase    three-wire

    Isolation    transformer

    630KVA

    1250KVA

    1250KVA

    Inrush    current

    Less than 7 times Ie

    Harmonic    distortion rate

    Less than 3% (secondary    side of transformer)


    DC side

    Rated voltage

    768V

    768V

    768V

    Lower limit    voltage

    600V

    600V

    600V

    Upper limit    voltage

    876V

    876V

    876V

    Rated current

    650A

    1300A

    1300A

    Cell    specifications

    280Ah

    280Ah

    280Ah

    Number of    batteries

    2880

    3360

    3840

    Number of    modules

    180

    210

    240

    Module    specifications

    1P16S

    1P16S

    1P16S

    Actual    capacity

    2580KWh

    3010KWh

    3440KWh


    Battery management

    Cluster    battery

    12

    14

    16

    Cluster unit

    12

    14

    16

    Voltage    accuracy

    0.002

    0.002

    0.002

    Temperature    accuracy

    0.01

    0.01

    0.01

    SOC accuracy

    0.05

    0.05

    0.05

    Power    accuracy

    0.01

    0.01

    0.01


    Cabinet

    Battery    cabinet

    966*855*2400mm

    966*855*2156mm

    966*855*2156mm

    Control    cabinet

    2000*600*700mm

    2000*600*700mm

    2000*600*700mm

    PCS cabinet

    1400*825*2180mm

    1400*825*2180mm

    1400*825*2180mm


    Air conditioning

    Installation    method

    Embedded

    Embedded

    Embedded

    Cold power

    30KW

    30KW

    30KW


    Fire control

    Fire fighting    medium

    Heptafluoropropane

    Spray method

    Pipeline (battery room)


    Fire detection tube (PCS    room)


    Communication Interface

    Wireless

    2G,1 minute update

    Wired

    Network, 5 seconds update

    System cycle    life

    >6000Cycle(25℃)

    >6000Cycle(25℃)

    >6000Cycle(25℃)

    Capacity    availability

    >80%

    >80%

    >80%

    Weight

    <20T

    <41T

    <45T

    Structure    size

    12.192m*2.438m*2.591m

    12.192m*2.438m*2.591m

    12.192m*2.438m*2.591m



FAQ

CFE Lithium-ion Battery




Q: What kind of battery you can provide?

A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.

    b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).

    c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.

    d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.

    e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).

    f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.


Q: What is the capacity of production?

A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.


Q:How long is the warranty period?

A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.


Q: How long is the estimated delivery time?

A: The delivery time is within 25 days after receiving the payment.


Q: Are you able to handle shipment transportation?

A: We can arrange the shipment to most places as required.


Q: What kind of certification do you have?

A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.


Q: What kind of product quality your factory offer?

A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .


Q: Can we print our logo on products?

A: We can provide one to one customized OEM with a MOQ demand.


Q: What is the validity of the quotation?

A: Due to the raw material price fluctuation, the quotation validity is 10 days.


Q: How to repair the battery?
To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
Q: How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q: What are the technical parameters of the battery?
The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: What are the hazards of battery over discharge?
Excessive discharge can seriously damage the battery's electrical performance and cycle life.
Q: What are the advantages of maintenance-free batteries?
Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
Q: What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q: The role of the battery?
It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
Q: What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q: Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords