Gel batteries with CE ROHS SGS 12v 50ah lead acid deep cycle battery
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Quick Details
Place of Origin: Jiangsu, China (Mainland)
Brand Name: oliter deep cycle battery
Model Number: LCPC50-12
Usage: UPS
Voltage: 12v
Sealed Type: Sealed
Maintenance Type: Free
Size: 227*138*228(mm)
Weight: 15±0.5KG
Nominal Capacity: 50AH
Model: 12V50AH
size: 227*138*228(mm)
Nominal Capacity: 50AH
self-discharge: <2%/month
packing: cartoon
use: deep cycle battery
Specifications
12v 50ah deep cycle battery
1)manufacture with good quality
2)MSDS,ROHS,ISO9001,ISO14001
3)export experience 15 years
Product Description
Item | 12V 50AH deep cycle battery |
Brand Name | Oliter |
Model NO. | LCPC50-12 |
Battery type | storage battery |
Battery dimension | 227*138*228(mm) (L*W*H) |
Nominal voltage | 12v |
Nominal capacity | 50ah |
Net Weight | 15kg |
Cycle life | 100%DOD 572times , 50%DOD 1485 times , 30%DOD 2406times |
Battery Case | ABS |
Plate | lead-antimony |
Payment terms | T/T(with 30% deposit),70% paid by the copy of BL |
Loading port | Shanghai |
Main Market | America,Africa, Mid-east,Asia ,South America, Europe |
- Q: How to repair the battery?
- To the battery in accordance with the 0.1C current discharge, record the discharge time. Its discharge current multiplied by the number of hours of time, is the battery repair capacity. If the Chongqing battery capacity to reach the nominal capacity of more than 70%, the end of the repair.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
- Q: How to deal with waste batteries?
- The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
- Q: What are the hazards of battery over discharge?
- When the battery discharge current is large, the heat will become more obvious, there will be serious heat generated when the battery deformation, when the concentration of lead sulfate is particularly large, will form a larger crystal particles, that lead to the battery Internal irreversible sulfation.
- Q: Maintenance-free battery how to detect it?
- Check the height of the electrolyte at least once a month. There is no mark line of the battery, the electrolyte added to the plate 10-15mm can be higher; there are two red line of the battery, the electrolyte can not exceed the red line above.
- Q: What are the advantages of maintenance-free batteries?
- Maintenance-free battery using lead-calcium alloy grille, the amount of water generated when charging less water evaporation is low, with the shell with a sealed structure, the release of sulfuric acid gas is also very little, so with the above advantages.
- Q: How should the battery be well maintained?
- Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
- Q: 80ah how much battery storage capacity?
- Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
- Q: How does the battery increase the voltage?
- You can use the same battery in series, with 5 12v battery in series becomes 60v, if you need the current is relatively small, you can use DC-DC module to 12v voltage rise to 60v.
- Q: What is a maintenanceable battery?
- It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
Send your message to us
Gel batteries with CE ROHS SGS 12v 50ah lead acid deep cycle battery
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 5000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords