Lithium-ion Battery Energy Storage System CFE Replacement LFP S Pro
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Lithium-ion Battery Energy Storage System CFE Replacement LFP S Pro
1、OLED power display screen and switch buttons.
2、Rugged stainless steel body with good looking.
3、High protection level IP65.
4、Quick connection and insulation protection.
5、Stainless steel handles guarantees 3000 fatigue tests.
6、Support external connections in series with voltage up to 51.2V.
7、 Support 6 batteries connected in parallel.
Product Description
Product Spec | |
Model | CFE-1280S Pro |
Nominal Voltage | 12.8V |
Nominal Capacity @1C | 100Ah |
Charge Voltage | 14.8V |
Charge Current Max Continuous | 50A |
Discharge Current Max Continuous | 100A |
Discharge Voltage Minimum | 10.8V |
Pulse Current 5 Sec | 150A |
Weight | 12.3kg±0.5kg |
Dimensions L*W*H(mm) | 320*140*210 |
Calendar Life & Performance Guarantee | a. 3500 cycles or 5 years , whichever comes first b. 1500 cycles or 2 years , whichever comes first |
Test conditions: 0.2C Charging/Discharging, @25°C, 80% DOD
FAQ
CFE Lithium-ion Battery
Q: What kind of battery you can provide?
A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.
b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).
c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.
d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.
e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).
f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.
Q: What is the capacity of production?
A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.
Q:How long is the warranty period?
A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.
Q: How long is the estimated delivery time?
A: The delivery time is within 25 days after receiving the payment.
Q: Are you able to handle shipment transportation?
A: We can arrange the shipment to most places as required.
Q: What kind of certification do you have?
A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.
Q: What kind of product quality your factory offer?
A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .
Q: Can we print our logo on products?
A: We can provide one to one customized OEM with a MOQ demand.
Q: What is the validity of the quotation?
A: Due to the raw material price fluctuation, the quotation validity is 10 days.
- Q:What is the difference between a maintenance-free battery and a conventional battery?
- As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
- Q:What are the technical parameters of the battery?
- The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
- Q:The role of the battery?
- It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
- Q:Maintenance-free battery how to detect it?
- Keep the battery surface clean. If the discovery of solid oxide on the pole, it should be timely with hot water pouring, to be removed, so as not to affect the pole and the terminal between the continuity. After cleaning up, wipe the battery surface, in the pole and the terminal cast on the butter to ensure that the pole is not oxidized.
- Q:80ah how much battery storage capacity?
- Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
- Q:What kind of battery is divided into?
- Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water. It also has a shock, high temperature, small size, self-discharge characteristics of the general life is generally ordinary Twice the battery. There are two kinds of maintenance-free batteries on the market.
- Q:How to determine the battery is good or bad?
- Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
- Q:What battery does the van use?
- General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
- Q:How should the battery be well maintained?
- Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
- Q:How to deal with waste batteries?
- The rest of the various types of waste batteries are generally shipped to a special toxic, hazardous landfill, but this approach not only cost too much but also cause waste, because there are many useful raw materials available.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Lithium-ion Battery Energy Storage System CFE Replacement LFP S Pro
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 1000000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords