Tubular motor accessory driving adapter CE TUV
- Loading Port:
- Ningbo
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 500 set
- Supply Capability:
- 400000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Tubular motor for roller shutter, electric awning, motorized blind, Roma shade;
Used for rolling windows, doors, blinds, screens and rolling shutters.
Projection screen, skylight shade, sunshade, sun protection, rolling door drive, security shutter operator.
CE, TUV, RoHS, CCC, ISO9001 certificated,
Safety, Energy saving, High efficiency, Long life time,
Low noise, Low temperature increasing, Low maintenance cost.
Standard: TUV, CE, CCC, UL
Productivity: 300, 000pcs/year
Origin: China
Packing: 6pcs/ctn, 1pc/colour box
Min. Order: 500pcs
Transportation: By sea or by air
Features Tubular motor for roller shutter:
1) Voltage: 230V/50Hz
2) Input power: 117W/ 215W
3) Current: 0.49A /0.92A
4) Speed: 12/16/25rpm
5) Torque: 10/15/20/30/40/50N. M
6) Working duration: ≥ 4min
7) Insulation classification: B
8) Protection classification: IP44
9) Certification: CE, TUV, CCC, ISO9001-2008 ROHS,
Outer packing Tubular motor for roller shutter:
6pcs/carton with foam in it
- Q: How to distinguish dc motor from ac motor?
- Relative decision, according to the purpose of the use dc motor energy saving, high power factor, but need to convert ac to dc, need to increase the current transformer, cause high cost; The ac motor is easy to use, the structure is simple, the relative noise is too loud, please make the decision according to the demand
- Q: The converter can control which motors
- Frequency converter (Variable frequency Drive, VFDS) is the application of frequency conversion technology and microelectronic technology, by changing the way to control the motor power frequency ac motor power control equipment. Inverter is mainly composed of rectifier (ac to dc), filter, inverter (dc to ac), brake unit, drive unit, detection unit micro processing unit, etc. Internal IGBT inverter on the open circuit to adjust the output of the power supply voltage and frequency, based on the actual needs of the motor to provide the needed power supply voltage, thus achieve the goal of energy saving and speed, in addition, the protection of the inverter and there are many functions, such as over-current, over-voltage protection, overload protection, etc. With the increasing degree of industrial automation, the frequency converter has been widely used.
- Q: How do I get 220v on the motor?
- First of all depends on the specific parameters of the motor, such as: rated voltage, dc motor or ac motor, ac motor is single-phase or three-phase motor, synchronous motor or induction moto
- Q: Single phase single capacitance ac motor three wires wrong
- The single phase motor is divided by the main winding and the starting winding, and the wrong turn can also be turned, but the electric opportunity quickly overheat and damage, the proposal to seek a professional to show you.
- Q: What is excitation, excitation current, what is the difference between motor and generator
- The excitation current is provided by the independent power supply for the motor excitation winding. For example, the use of an independent dc power source for the excitation winding of a dc generator; The electromagnetic field of the armature winding of the asynchronous motor is generated by ac power supply. The former is the dc excitation, the latter is the exchange excitation. Synchronous motor according to the situation of the power grid, can be a rotor field winding dc excitation, can also be provided by the grid ac excitation on the stator, the general is given priority to with dc excitation. If the dc excitation is insufficient, then the reactive reactive current from the grid input is added to the motor. If the dc excitation method is overused, the motor will output the backward reactive current to the grid, weakening the internal magnetic field of the motor. When the dc excitation is adopted, the voltage drop in the excitation circuit is only caused by the resistance, the excitation voltage is low, and the excitation power supply is small. With the use of ac excitation, the excitation voltage is much higher, and the capacity of excitation power supply is much higher.
- Q: Does the train use dc or ac?
- Alternating current (ac) in 48 v the following safety voltage range Can form loop with a line. A line of fire, tracks or earth is zero. 48 v alternating current (ac) is not allowed above the earth or other bare conductors as the zero line is based on the safety of think. More than 48 v ac voltage, if zero line bad earth contact naked outside zero to get an electric shock accidents. I don't know much about electric motors on the railroad. I haven't seen anything like that. Sorry.
- Q: Three-phase ac motor star row and delta connection?
- Three-phase squirrel-cage asynchronous motor adopts - delta Y step-down starting advantage: Y connection of the stator winding, the starting voltage for direct using delta connection, a third of the 1/3 of the starting current to delta connection, thus features good starting current, the circuit is simple, less investment. The drawback is that the torque is reduced to a third of the triangular method, and the torque characteristics are poor. So the line is suitable for light or no-load start. In addition, note that the consistency of the rotation direction should be noted when the y-delta joins
- Q: What kind of motor can be added
- This motor can only be adjusted by frequency conversion. Because of the lowering of the speed control, the electrical opportunity can not work, or even burn. It can also be used for speed reduction gear Governor (called) is a kind of automatic adjustment device, according to the change of the diesel engine load, it automatically increase or decrease in fuel injection pump oil, the diesel engine to run at a steady speed.
- Q: How to control the start-stop of 220V ac motor with a single chip? What type will you use for the relay
- The current amplification comes directly with a triode, which is based on the control voltage of your relay. The 12-24v dc relay is usually selected. The protective circuit of heat relay is optional according to need.
- Q: What's the total number of ac motor governor? The most common, each principle, the detailed point, the master thank you Please be more careful, the principle means thank you
- Ac motor speed governor generally refers to the electromagnetic speed regulating motor controller. Now the gear speed machine, also called ac motor speed, the best you know that will you use it first.
Send your message to us