• solar lithium high voltage storage  battery lithium batteries pack NCQ System 1
  • solar lithium high voltage storage  battery lithium batteries pack NCQ System 2
  • solar lithium high voltage storage  battery lithium batteries pack NCQ System 3
  • solar lithium high voltage storage  battery lithium batteries pack NCQ System 4
solar lithium high voltage storage  battery lithium batteries pack NCQ

solar lithium high voltage storage battery lithium batteries pack NCQ

Ref Price:
get latest price
Loading Port:
SHANGHAI
Payment Terms:
TT OR LC
Min Order Qty:
10 SET
Supply Capability:
100 SET/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Parameters

Product Model

HV-BOx2-384

Product Specification

384V 10KWH

Nominal Voltage

384v

Nominal Capacity

27Ah

Cell Type

(LFP)

Standard Charge Voltage

438V

Max Charge Current

1C

Discharge Cut-Off Voltage

300v

Max Discharge Current

1C

Protection level

4 levels Battery Management Protection

Communication Interface

CAN

Cycle Life*

≥6000 cycles (80%DOD)

Charge Temperature

Range 0~65℃

Discharge Temperature

Range -20~65℃

Parallels Function

Support 10 Units In Parallels

Dimensions

980*520*20OMM

Weight

92Kg

Installation Method

(Floor Mounted Type)

 

Source with confidence

 Direct from Verified Custom Manufacturer

 

Application Areas:

Energy storage system, control system, alarm system, power system, database Emergency lighting system, emergency power supply, UPS Telecommunication, communication, fire fighting system, Solar/wind energy storage, Back-up power for small UPS.

 

Product features:

Professional design, stylish shell, good interface.

Modular Design, free combination, easy to transport and install.

Thick shell, good protection for internal cells.

Smart protection, customized BMS to avoid overcharging.

High energy battery, high energy density term and conversion efficiency.

Fast charging, 1C high performance battery.

Long cycle life, high quality cells provide longer service life.

Stable performance, can normally work under high temperature.

 

OrderOrderOrder

CONVENIENT AND BEAUTIFUL ENERGY STORAGE DEVICE, TO ENSURE THAT YOU CAN GET THE LIGHT AT ANY TIME AND PLACE. TO ORDER IT, QUALITY SERVICE, REASONABLE PRICE AND PERFECT AFTER-SALES.

 

 

 

FAQ:

 

Can I have a sample order?

A. Yes, welcome sample order to test and check quality.

 

How about after-sales service?

A. We will provide you with a 3 years warranty. If there are any problems, please let us know and we will provide you with a positive solution.

 

 What about the lead time?

A. Sample 5-10 days, mass production time 3-5 weeks depending on order quantity.

 

Do you have any MOQ limit?

A. Yes, but low MOQ, 10pcs order is available.

 

How do you ship the goods and how long does it take to arrive?

A. We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Bigger order shipped by air or by sea.

 

How to proceed with an order?

A. 1st, please let us know your requirements or application. 2nd, We offer our quotation. 3rd, customer confirms the samples and make a deposit for formal order. 4th, We produce your order.

 

Can you print my logo on the product?

A. Yes. Please supply us the artwork before mass production.


Q: How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q: What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q: Maintenance-free battery how to detect it?
Battery pole Pole terminal has corrosive material without treatment, as long as no loose on it. If the appearance of the corrosive material, the inner surface of the terminal will also be corrosion, resulting in increased resistance, affecting the normal battery charging and discharge, it must be promptly processed.
Q: What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q: What is the meaning of the battery above 12v65Ah?
Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
Q: How should the battery be well maintained?
Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
Q: 80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q: What is a maintenanceable battery?
This is relative to a maintenance-free battery. Maintenance of the battery needs to be supplemented with electrolyte to ensure work, while maintenance-free is not required.
Q: Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords