• Raw Materials for Refractory:Silicon Carbide for Refractory Castables for Ladles Supplied by CNBM System 1
  • Raw Materials for Refractory:Silicon Carbide for Refractory Castables for Ladles Supplied by CNBM System 2
Raw Materials for Refractory:Silicon Carbide for Refractory Castables for Ladles Supplied by CNBM

Raw Materials for Refractory:Silicon Carbide for Refractory Castables for Ladles Supplied by CNBM

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
2500 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

Place of Origin:

Henan, China (Mainland)

Shape:

Powder

Material:

Clay,Alumina magnesia,Bauxite-mullite,Corundun

SiO2 Content (%):

15%-30%

Al2O3 Content (%):

45%-90%

MgO Content (%):

4.4%

CaO Content (%):

1.2-3.2%

Refractoriness (Degree):

Common (1580°< Refractoriness< 1770°)

CrO Content (%):

Appropriate

SiC Content (%):

Appropriate

Model Number:

Customer's Requirement, refractory castable

Brand Name:

cnbm

Compressive strength 1000°C:

40-74Mpa

Compressive strength 1500°C:

43-150Mpa

Bending Strength 1000°C:

11-19Mpa

Bulk density(g/cm3):

2.3

Bending Strength 1500°C:

13-23Mpa

Reheating linear change 1000°C:

-0.02-+0.08

Reheating linear change 1500°C:

+0.10-+0.62

Max Service temperature °C ≥:

1650

Color:

White,Yellow,Grey Green etc

Packaging & Delivery

Packaging Details:1.25kg/Bag 
2.As your demands
Delivery Detail:30 days after down deposit

Silicon Carbide for refractory castables for ladles

Specifications&Data

What is the details of our steel fiber reinforced refractory castable?

Steel fiber reinforced refractory castable is a special castable which is added steel fiber into the castable,can improve the toughness,mechanical strength,thermal shock resistance and spalling resistance.

What is the Feature of Our steel fiber reinforced refractory castable?

1.High mechanical strength,

2.Good thermal shock resistance,

3.Good toughness and anti-stripping,

4.High refractoriness,

5.Tiny linear variation,no cracking,

6.Resistant to scour and erosion,

7.Good volume stability under high temperature.

What is the Applications of our steel fiber reinforced refractory castable?

Steel fiber reinforced refractory castable is mainly used in heat treatment furnace,heating furnace,soaking pit furnace,tundish slag dam weir,seconclary refining and the catalytic cracking unit etc key part of kiln furnace and thermal equipment.

What is the Technique Data of our steel fiber reinforced refractory castable?

Item

Fire clay

High alumina

Corundum

Chemical Composition %

Al2O3 ≥

45

75

90

CaO ≤

1.0

1.0

1.0

 

Bulk density g/cm3

110°C,24h

2.40

2.70

3.15

1350°C,3h

2.35

-

-

1500°C,3h

-

2.65

3.10(1550°C)

Reheating linearchange %

1350°C,3h

±0.5

-

-

1500°C,3h

-

±0.5

±0.5(1550°C)

 

Bending Strength MPa

110°C,24h

6

7

7

1350°C,3h

8

-

-

1500°C,3h

-

10

10(1550°C)

 

Compressive strength MPa

110°C,24h

40

40

40

1350°C,3h

75

-

-

1500°C,3h

-

85

90(1550°C)

Service temperature °C ≥

1500

1550

1650

 Silicon Carbide for Refractory Castables for Ladles Supplied by CNBM


Q: how to use boiler fireclay
Boiler refractory, diluted with water to touch the places where needed, can be used after high temperature baking.
Q: What do we mean by saying that a ladle cover knots, elbow knots, blowpipe knots in refractory materials? What is the “knot”?
Go eastward 200 meters from the south gate of cultural square.
Q: Does anyone know about the fire resistance period of thin fireproof coatings?
The columns are 2.5 to 3.0 hours, beams are 2.5 hours, C-shaped steels are 0.5 hours. The thin steelwork fireproof coatings are primarily water-soluble, which will be expanded and foamed when exposing to the fire. Thus the fire-resistant insulation layer formed through expansion and foaming will delay the temperature increase of the steel and protect of steel components. The thin fireproof coatings are made of adhesives, catalysts, carburizers, foamers, fillers, fibers and modifiers. The required emulsion polymers must have good adhesion, durability, and water-resistance to the steel substrates. The coating has a strong adhesion and good flexibility, is light and thin, as well as highly resistant to vibration. It is especially applicable for indoor bareness steel structure, light layer steel structure, and steel structure with decoration demands whose fire resistance requirement is within 1.5-2.5 hours.
Q: Manganese steel belongs to refractories
Material wear and other harsh working conditions, extrusion, there will be work-hardening phenomenon rapidly on the surface. The most important feature of manganese steel is that it is not refractory under a strong impact, and under extrusion conditions, part of it will be fractured. The main form of damage is wear and consumption: It is a kind of inorganic non-metallic material whose refractoriness is not lower than 1580 ℃, mainly used to endure impact. Manganese steel is a kind of high strength steel, which is free of deformation, so that it can remain austenite good toughness and ductility at heart while keeping good wear resistance at the same time on hardened layer. Refractories are
Q: Does anyone know what is a lightweight refractory material?
Light weighted castable is one of the kind.
Q: Which one is the best refractory material?
Resin bonded refractory is mainly abot aluminum magnesium carbon, and carbonaceous etc. Thermoplastic resins need to add the coagulant (Uto), ageing mixture for a period of time, so the production cycle is long. Hot hard resin is relatively not so complex, but it’s not as good as thermoplastic resins in thermoplastic binding.
Q: What is shapeless refractory with high performance?
The popular ones are: Non-cement fine powder bonded castable is a functional refractory castable with nano material introduced.
Q: Is there anyone who can explain how to grade the level of fire insulation board?
1, Combustion performance of building material is divided into the following several class according to China's national standard GB8624-97 Class a: Non combustible building materials: Non-conbustible material. Class B1: Refractory building materials: Flame retardant materials have good flame retardant effect. It hardly catch on fire in the case of open flame and high temperature, do not spread fire quickly, and when the fire source is removed, fire will be stopped immediately. Class B2: Combustible building materials: Combustible materials have certain flame retardant effect. In case of fire or under high temperature, it will immediately burst into flames, easily leading to spread of fire , such as poles, wooden frame, timber, and wood stairs. Class B3: Combustible building materials: Without any flame retardant effect, will be burnt easily, resulting in high risk of fire. I Hope my answer will help you.
Q: what is the specs of thermal insulation refractory slab ?
Fireproof insulation specification is 1220 * 2420 1220 * 2420 * 8 * 9. HPL also known as the fireproof board is scientificly named thermosetting resin impregnated paper laminated wood, the abbreviation of which is HPL.Decorative high-pressure Laminate is fire-resistant building materials for decorative purposes. It is rich in surface color, texture and special logistics performance, widely used in interior decoration, furniture, kitchen cabinets, laboratory table, external walls.
Q: Is it normal for caable fire resistant material to catch on fire?
Abnormal, preventive measures: 1 take fire preventive measures. Measures taken for fire retardant measures of cable: (1) seal closely with fire resistant materials holes ran by cables through walls, shafts to prevent the cable fire, high temperature gas diffusion and spread when cables are on fire. (2) to wrap the cable with the insulation refractory material, when the cable is surrounded with fire, warpped cable is insulated by the insulation material from fire, so it will not be burned. If the cable itself is on fire, fire will be extinguished thankes to lack of oxygen in warpped cable, to avoid the fire to spread out. 2 to strengthen the cable circuit switch and regular protective check and maintenance, to ensure that the action is reliable. 3 to strengthen the cable operation and monitoring, to avoid the overload of the cable operation. . 4 regularly clean dust on the cable, to prevent cable from catching on fire due to the accumulation of dust. 5 to ensure the construction quality, the quality the cable must be strictly in line with the requirements and standards. 6 cable laying should maintain enough distance form the heat pipe, control cable is no longer than 0.5 meters; power cable is no longer than l meters. Control cable and power cable should be divided into slots, be layered and seperated instead of being overlapped . For the parts that do not meet the requirements, measures must be taken to insulate heat and fire. 7 regularly teat cable , abnormal problem should be handled in a timely manner. 8 install fire alarm so that fire will be discovered on time, and cables will not catch on fire. 9 the cable trench should be kept dry to prevent the cable from being affected with damp, or leading to declined insulating function and short circuit.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords