Raw Materials for Refractory:Calcined Magnesite Powder
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
Caustic Calcined Magnesite Powder
Product Category: 85 Grade,80 Grade,75Grade,70Grade
Caustic Calcined Manesite Ball
Caustic Calcined Magnesite Powder
Product Category: 85 Grade,80 Grade,75Grade,70Grade
Caustic Calcined Manesite Ball
Product Category: 85 Grade,80 Grade,75Grade,70Grade
Caustic Calcined Manesite Ball | Product Grade | |||
Product Category | 85 | 80 | 75 | 70 |
MgO content | 85% | 80% | 75% | 70% |
Calcium oxide(CaO) | 2.5% | 2.5% | 3% | 3% |
Loss On Ingition | 7% | 10% | 12% | 16% |
Silica SiO2 | 6% | 8% | 10% | 10% |
Particle size | ≤ 120 | ≤ 120 | ≤ 120 | ≤ 120 |
No. Item Result
1 MgO % 98%min
Clarity Test OK
2 CaO 0.2%max
3 Fe 0.0075%max
Cl 0.035%max
SO4 1.0%max
4 Insoluble matter in acid 0.1%max
Heavy Metal 20ppm max
5 Bulk Density 0.32g/ml
Heating Loss 0.8%max
6 Screenings 250 99.5%
- Q: What type of firebrick does TZ-3 represent?
- Height is 65mm, length is 230mm, and width is 114mm, that is the t-3 firebricks which meet the national standard.
- Q: What does the function of SiC for refractories?
- Anti-wear! High intensity!
- Q: What are included in fireproofing materials?
- There are many types of fireproof materials, and the following listed below is the main species: All kinds of fire retardant coating such as finishing fire retardant paint, fire retardant coating components, fire-resistant coating for steel structure; all kinds of fire-proof materials such as fire?retardant material and its products, textile, fire?retardant fabric, building materials and products, flooring material and external wall thermal insulation system; all kinds of fireproofing components such as fireproof?panel, fire door, fire resistant window frame, fire resisting shutter, fireproofing glass, elevator landing door,ventilating duct, fire-proof?sealing?material and fire protection smoke exhaust fan. The main indicators to judge fire resistance are: Flame retardency, ignition,production of?toxic?gases, smoke density,heat release and exhaust gas; fire resistance, combustion performance, heat of combustion, fire-resistant performance, high temperature resistance, fire?rating, etc. There are some specific parameters which need to be judged by a professional testing equipment. You can go to the inorganic laboratory to check. The test results of fire rating are accurate.
- Q: How should fireproof building materials be ranked?
- 5. Civil building 5.1. Fire resistance rating, number of layers and floorage of civil buildings 5.1.1. Fire resistance rating of civil buildings should be classified into four levels of first, second, third and fourth. Unless otherwise specified in the code, the combustion performance and fire endurance of building components with different fire resistance rating should be no less than that of the regulations in Table 5.1.1. Table 5.1.1: Combustion Performance and Fire Endurance (h) of Building Components (Figure) Note: 1. Unless otherwise specified in the Code, the fire resistance rating of the building with wooden pillars as load-bearing and incombustible material as the building wall should be the fourth level; 2. For the suspended ceiling of the building with the second level of fire resistance rating, if it uses non-combustible component, it won't be limited in its fire endurance; 3. For buildings with the second level of fire resistance rating, if it is really difficult for the partition wall of rooms with the area of no less than 100m2 to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.3h; 4. For buildings with the first or second level of fire resistance rating, if it is really difficult for the partition wall of both sides of the evacuation walk to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.75h. 5. Fire endurance and combustion performance of the residential building component can be implemented in accordance with the provisions of current national standard GB 50368 "Residential Building Code".
- Q: What is refractory aggregate?
- It includes two categories: coarse aggregate and fine aggregate.
- Q: What's the type of fire proofing thermal insulation materials?
- Aluminum silicate: AlSiO3 With flint clay clinker as raw material, aluminum silicate is made by resistance or electric-arc furnace fusion and then spraying processing. Aluminum silicate fiber, also known as ceramic fiber, is a new lightweight refractory material featured by light weight, high temperature resistance, good thermal stability, low heat conduction rate, small heat capacity, good mechanical vibration resistance, small thermal expansion and good thermal insulation. It can be processed into aluminum silicate fiber board, aluminium silicate fiber felt, aluminium silicate fiber rope, aluminium silicate fiber blanket, etc. Featured by high temperature resistance, low heat conductivity coefficient, light weight, long life, good tensile strength and elasticity and no toxin, this new sealing material is an alternative of asbestos and widely used for thermal insulation of thermal energy equipment in metallurgy, electric power, machinery, chemical industry, etc.
- Q: What are the disadvantages of the refractory industry?
- The rapid development of continuous casting technology allows Hua Heng refractories to be improved in variety and quality. The development of refractory for continuous casting has a significant impact on the production of continuous casting and quality of continuous casting billet. Constructing and putting Baosteel into action has greatly pushed the improvement of the refractory technology. Continuous casting refractory is an important part of the continuous casting machine. In addition to the general characteristics of refractories, it is also required functions that can purify molten steel, improve the quality of steel, stabilize temperature and composition of the molten steel, control and regulate the molten steel flow. Therefore, it is known as functional refractories. Continuous casting Refractories include: (1) ladle refractory - ladle lining, permanent lining and ventilation components; (2) tundish refractories - permanent lining, coating, insulating plates, clad etc; (3 ) functional refractories - long nozzle for non-oxidizing casting, submerged nozzle, monolithic stopper, sliding gate; (4) ceramic purifier for purifying molten , slag dam, alkaline paint and horizontal separating ring and gate board for continuous casting.
- Q: what is the specs of thermal insulation refractory slab ?
- According to different requirements of each project to select the fire board. fireproof?panel should have product qualification certificate. Specifications shall comply with the requirements of design drawings and inspection reports from the National Fireproofing Protection Building Materials Inspection Center. General specifications are as follows: Length: it is determined according to the project width: 1200mm, 900mm; thickness: 9.5mm, 12mm, 15mm, 18mm, 25mm. Commonly used is 12mm. According to different requirements of each project to select the fire board. Fireproof?panel should have product qualification certificate. Specifications shall comply with the requirements of design drawings and inspection reports from the National Fireproofing Protection Building Materials Inspection Center. General specifications are as follows: Length: It is determined according to the project width: 1200mm, 900mm; thickness: 9.5mm, 12mm, 15mm, 18mm, 25mm. Commonly used is 12mm.
- Q: how does the fire endurance of first rate fire resistant window?
- how does the fire endurance of first rate fire resistant window? I really don't know it and I need a specific direct and detailed answer!
- Q: How to classify fire resistance rating of brick-concrete structure?
- In order to ensure the safety of the building, the fire protection measures must be taken to make it have a certain degree of fire resistance, even if there is a fire, it will not cause too much damage. According to the national conditions of our country, and in the light of other countries standards, < high-rise civil building fire protection design specification > defines fireproof rank of high-rise civil buildings into level one and two; < code for fire protection design of buildings > divides the rank into level one, two, three, four, level one is the highest level, level four is the lowest. Besides that the minimum fire resistance of the building component is specified, buildings of fire resistance rating also specified requirements for combustion performance. Because the component with the same fire resistance limit is different, it is different in the fire.According to our country national standard < building design fire protection code >, the fire resistance rating of the building is divided into four levels. The fire resistance of a building is determined by the combustion performance and fire resistance of building components (such as beams, columns, floors, walls, etc.). Generally speaking, the fire resistance building of level one is a mixed structure of reinforced concrete structure or a mixture of brick wall and steel concrete structure; the fire resistance building of level two is a mixed structure of steel truss structure, reinforced concrete column and brick wall; the fire resistance building of level three is brick-wood structure made of wood roof and brick wall; the fire resistance building of level four is combustible structure which is composed of wood roof and non-combustible wall.
Send your message to us
Raw Materials for Refractory:Calcined Magnesite Powder
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords