MODEL

STANDARD

DX/CX6K

DX/CX 10K

DX/CX6KL

DX/CX10KL

CAPACITY

VA/W

6KVA/4.8KW

10KVA/8KW

6KVA/4.8KW

10KVA/7KW

INPUT

Nominal Voltage

220/230/240VAC

Voltage Range

120-275VAC

Frequency Range

46-64Hz: 50Hz, 60Hz auto sense

Phase

Single phase with Ground

Power Factor

>=0.99

OUTPUT

Voltage

220/230/240*(1±1%)VAC

Frequency

50/60Hz(Adjustable)

 

50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.1%)

60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.1%)

 

Wave Form

Pure Sine Wave

Power Factor

0.8

Harmonic Distortion

=<2% THD (Linear Load), =<6% THD (Non-Linear Load)

Overload Capacity

Normal when load < 105%; 105%-125% for 1 min, 125%-150% for 30sec

Current Crest Ratio

3:1

Connections

Terminal block

Efficiency

To AC Mode

88%

To Battery Mode

up to 90%

Battery

Type

Sealed free maintenance lead acid battery

Nominal DC voltage

Built in batteries 12v7.2ah*16pcs

192VDC

192VDC

Quantity

16pcs

16pcs

Depends on requested back-up time

Depends on requested back-up time

Back-up Time (Full load)

>=7 min

>=5 min

Depends on the capacity of external battery bank

Depends on the capacity of external battery bank

Recharge Time

7 hours to 90%

Depends on the capacity of external battery bank

Depends on the capacity of external battery bank

Charge current(MAX)

2.0A

4.2A or 8A

4.2A or 8A

Charge voltage

220Vdc ± 1%

Bypass

Automatic Transfer

On overload and UPS failure

Before UPS Power-on

Default "ON" user adjustable to "YES"

Transfer Time

 

Zero

Indicators

LCD Display

UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault code

Audible Alarm

 

Bypass, On battery mode, Battery low, Overload, Fault

Acoustic noise

At 1 meter distance

<55dB

Communications

Intelligent RS232 serial port

Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC

SNMP (Optional)

Power management from SNMP manager and web browser

USB (Optional)

Windows family software and Mac OS

Environmental

Operating Temperature

0~40 °C

Operating Humidity

20~90% ( Non Condensing)

Weight

Net weight (kg)

84

93

35

38

35

UPS Dimension

L*W*H (mm)

570*260*717

 

Q: How many power illuminator can 5Kva 36V transformer drive?
The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
Q: What transformer can be used in a safety voltage lighting transformer?
An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
Q: How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
Voltage x current = power, in general we are using the total power of 2/3, you can press this type of calculation, if the installation of electrodeless lights, the line should be separated,
Q: What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q: Why should lighting transformers be used in factories and mines?
There are two cases. One is the general factories and mines, and the low voltage is three-phase four wire system, and the neutral point is directly grounded. Between the phase line and the zero line is 220V, which can be connected with the illumination load.
Q: Is the substation separate from the power and illumination transformer?
There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
Q: The transformer zero line has broken, has the result to the household illumination circuit?
The lighting circuit mostly 3 phase unbalanced load, there will be zero drift, zero if the transformer line is broken, part of the lighting circuit to form a series of equipment in the case of two-phase circuit, circuit voltage is decreased and the lighting brightness is not enough, circuit voltage increases, the lamp burned;
Q: How many A leakage protection switches are used in 5000VA lighting transformers?
AC circuit transformer for lighting lamp is suitable for 50-60Hz, is the power supply with safety shell low-voltage safety lights, can choose 220V or 380V power supply input voltage: 0V, 220V, 380V, 0V, 6.3V, output voltage: 12V, 24V, 36V.
Q: Power and lighting transformers, lighting quality will be affected much?
First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
Q: Why can't autotransformer be used as transformer for safety lighting?
When a fault occurs, leakage of electric leakage occurs, and the original coil is transmitted to the residents at high voltage, causing disastrous effects on the human body and property!
We are now looking forward to your kind cooperation, and will be highly appreciated for that. We sincerely hope to cooperate with you in the lighting field. Please don't hesitate to contact us at your convenience.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords