MODEL | STANDARD | DX/CX6K | DX/CX 10K | DX/CX6KL | DX/CX10KL | |
CAPACITY | VA/W | 6KVA/4.8KW | 10KVA/8KW | 6KVA/4.8KW | 10KVA/7KW | |
INPUT | Nominal Voltage | 220/230/240VAC | ||||
Voltage Range | 120-275VAC | |||||
Frequency Range | 46-64Hz: 50Hz, 60Hz auto sense | |||||
Phase | Single phase with Ground | |||||
Power Factor | >=0.99 | |||||
OUTPUT | Voltage | 220/230/240*(1±1%)VAC | ||||
Frequency | 50/60Hz(Adjustable)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.1%) 60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.1%)
| |||||
Wave Form | Pure Sine Wave | |||||
Power Factor | 0.8 | |||||
Harmonic Distortion | =<2% THD (Linear Load), =<6% THD (Non-Linear Load) | |||||
Overload Capacity | Normal when load < 105%; 105%-125% for 1 min, 125%-150% for 30sec | |||||
Current Crest Ratio | 3:1 | |||||
Connections | Terminal block | |||||
Efficiency | To AC Mode | 88% | ||||
To Battery Mode | up to 90% | |||||
Battery | Type | Sealed free maintenance lead acid battery | ||||
Nominal DC voltage | Built in batteries 12v7.2ah*16pcs | 192VDC | 192VDC | |||
Quantity | 16pcs | 16pcs | Depends on requested back-up time | Depends on requested back-up time | ||
Back-up Time (Full load) | >=7 min | >=5 min | Depends on the capacity of external battery bank | Depends on the capacity of external battery bank | ||
Recharge Time | 7 hours to 90% | Depends on the capacity of external battery bank | Depends on the capacity of external battery bank | |||
Charge current(MAX) | 2.0A | 4.2A or 8A | 4.2A or 8A | |||
Charge voltage | 220Vdc ± 1% | |||||
Bypass | Automatic Transfer | On overload and UPS failure | ||||
Before UPS Power-on | Default "ON" user adjustable to "YES" | |||||
Transfer Time |
| Zero | ||||
Indicators | LCD Display | UPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault code | ||||
Audible Alarm |
| Bypass, On battery mode, Battery low, Overload, Fault | ||||
Acoustic noise | At 1 meter distance | <55dB | ||||
Communications | Intelligent RS232 serial port | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC | ||||
SNMP (Optional) | Power management from SNMP manager and web browser | |||||
USB (Optional) | Windows family software and Mac OS | |||||
Environmental | Operating Temperature | 0~40 °C | ||||
Operating Humidity | 20~90% ( Non Condensing) | |||||
Weight | Net weight (kg) | 84 | 93 | 35 | 38 | 35 |
UPS Dimension | L*W*H (mm) | 570*260*717 |
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- In general, indoor transformers are used in general practice
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: Why is the two side of the lighting transformer grounded?
- Single-phase transformer two side lighting to the ground, on the one hand is the lighting products now contain many semiconductor devices such as diodes, transistors, integrated circuits, semiconductor devices vulnerable to electrostatic damage, two side grounding contributes to the surge pressure factors produced by residual electrostatic discharge stay in the main circuit, avoid electrostatic protection, product life. In the 21 aspect, there is distributed capacitance between the two side and the primary side of the power transformer, and the high frequency surge disturbance caused by the primary side current source will directly enter the two side to the main circuit through the distributed capacitor. These unnecessary high frequency interference may jump into the sensitive signal source, make the control system malfunction, and the two side grounding of the power transformer can eliminate most of the undesirable effects of the distributed capacitance.
- Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
- Q: Why is elevator lighting transformer installed?
- 3 a power outlet shall be provided at the bottom pit.4 the cables and wires laid in the hoistway shall be flame retardant and damp resistant, and shall be protected by a nonflammable wire, conduit, or wire slot, with no use of wires, conduits, or wire slots made of combustible material.5 an elevator attached to a building whose wiring, materials and methods and electrical components used shall take into account the effects of climatic conditions and shall take waterproof measures.Lighting transformers in order to obtain 36V voltage
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- I don't know how much the output voltage of your transformer is, but the internationally accepted voltage below 36V is the voltage that is not harmful to the human body
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
- Q: Why can't autotransformer be used as transformer for safety lighting?
- The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
- Q: What's the function of the lighting transformer?
- Illumination transformer: usually refers to the secondary output voltage for the safety voltage 24V - 36V, only for special lighting power supply using voltage converter.
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Pe=19.5KW, installed capacityKx=1 coefficient of demandPjs=KxPe=19.5KW, calculated loadCOS, phi, =0.85, power factorIjs=KxPe/3/220/cos phi (Ijs calculates current, voltage, 380V/220V, three-phase)=1*19.5*1000/3/220/0.85=34.76A
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Parallel Redundancy UPS Power System
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Unit pc
- Supply Capability:
- 1000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords