Month LED Spot Light MR16
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Parameter
Model | FXMR16 4*1WB | |
Warm White | White | |
Color temperature | 2700-3200K | 6000-6500K |
LEDS | 4 LEDs | |
30º//45º/60º/ | ||
5 W | ||
400LM | ||
12V DC/AC | ||
-20-50°C | ||
30000-50000 | ||
Ø50*50 | ||
GU5.3 | ||
50W |
Features
1.Energy-efficient:Save 80% energy more than incandescent lamp.
2.Environmentally friendly:No any mercury and radiation like ultraviolet radiation and infrared light,ect.
3.Quick response,no strobe,no buzzing noise,instant soft start,and low heat.
4.High shock/vibration resistant.
5.Customized products are available according to your requirements.
6.More than 40000 hours lifespan
Application
-The replacement of traditional halogen bulb.
-lllumination and decoration at home and publix areas.
-Suitable for hotel,meeting room,show room,shop,telephone booth, etc
- Q: How many power illuminator can 5Kva 36V transformer drive?
- By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
- Q: What transformer can be used in a safety voltage lighting transformer?
- 220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q: Why is the two side of the lighting transformer grounded?
- Today's lighting products, regardless of the control system or the electronic power system itself, contain many semiconductorsComponents such as rectifier diodes, transistors, integrated circuits, LED, and so on. Semiconductor components are susceptible to staticElectrical damage, the two side of the power transformer grounding, help to produce a variety of factors, high pressure, residual static electricityDrain to avoid static electricity on the main circuit, to ensure product life.
- Q: Why is elevator lighting transformer installed?
- 3 a power outlet shall be provided at the bottom pit.4 the cables and wires laid in the hoistway shall be flame retardant and damp resistant, and shall be protected by a nonflammable wire, conduit, or wire slot, with no use of wires, conduits, or wire slots made of combustible material.5 an elevator attached to a building whose wiring, materials and methods and electrical components used shall take into account the effects of climatic conditions and shall take waterproof measures.Lighting transformers in order to obtain 36V voltage
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- When the zero line break line is not broken, the voltage drift of the point voltage leads to the rise of the 220V branch voltage and the reduction of the 220V branch voltage
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
- Q: How is the lighting power of the 380V transformer calculated?
- Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
1. Manufacturer Overview
Location | Zhejiang,China |
Year Established | 2008 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Month LED Spot Light MR16
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1 Piece pc
- Supply Capability:
- 50000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords