LFP Battery Energy Storage System CFE-POWERSTORM AC 1200W 1800W 3.7V 282000mAh 3.7V 451200mAh
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 10000000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
LFP Battery Energy Storage System CFE-POWERSTORM AC 1200W 1800W 3.7V 282000mAh 3.7V 451200mAh
1. Support DC output, USB-A port supports QC3.0 output 18W , Type-C port supports PD 60W output
2. AC output rated power: 1200W, 1800W
3. The output voltage is: 220V~230V pure sine wave
4. The Powerstorm can be charged by the car through the cigarette lighter socket
5. Real-time information display on the LED screen, with overcharge, over discharge, over current, short circuit, over temperature, overload protection functions
6. Support 15W wireless fast charging, available for Android and IOS, 8mm inductive fast charging, intelligent power-off
Product Description
Product Spec | ||
Rated power | 1200W | 1800W |
Rated capacity | 999Wh | 1598Wh |
Standard capacity | 3.7V/282000mAh | 3.7V/451200mAh |
Overload protection | 1200+80W | 1980+80W |
Ac output | 4*220V±10%/50HZ | 4*220V±10%/50HZ |
AC parallel connection | POWERSTORM-1200 | POWERSTORM-1800 |
Output wavefom | pure sine wave | pure sine wave |
USB output | 4*QC3.0/18W | 4*QC3.0/18W |
Output Type-C | 2*PD60W | 2*PD60W |
Lighter output | 1*14V/8A | 1*14V/8A |
DC55*2.5 output | 2*14V/8A | 2*14V/8A |
Wireless charger | 15W | 15W |
Charging input voltage | 12-26V | 12-26V |
MPPT input voltage | 18-75V,300W | 18-75V,300W |
Display | 3.5',480*320RGB | 3.5',480*320RGB |
Working temperature | -10 - 40°C | -10 - 40°C |
Weight(net weight) | ≈9.8kg | ≈12.8kg |
Weight(including accessories) | ≈10.8kg | ≈13.8kg |
Product size | 361mm*261mm*234mm | 361mm*261mm*234mm |
Storage Temp | -4 to 113℉(-20 to 45°C) | -4 to 113℉(-20 to 45°C) |
FAQ
CFE Lithium-ion Battery
Q: What kind of battery you can provide?
A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.
b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).
c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.
d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.
e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).
f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.
Q: What is the capacity of production?
A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.
Q:How long is the warranty period?
A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.
Q: How long is the estimated delivery time?
A: The delivery time is within 25 days after receiving the payment.
Q: Are you able to handle shipment transportation?
A: We can arrange the shipment to most places as required.
Q: What kind of certification do you have?
A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.
Q: What kind of product quality your factory offer?
A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .
Q: Can we print our logo on products?
A: We can provide one to one customized OEM with a MOQ demand.
Q: What is the validity of the quotation?
A: Due to the raw material price fluctuation, the quotation validity is 10 days.
- Q: How is the capacity of the battery defined?
- The capacity of the battery unit is AH (safety) is the product of current and time.
- Q: What is the difference between a maintenance-free battery and a conventional battery?
- Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
- Q: What are the technical parameters of the battery?
- Usually the capacity of the power supply is expressed by kV · A or kW. However, as a power supply VRLA battery, the use of security (A · h) that its capacity is more accurate.
- Q: How to determine the battery is good or bad?
- General side maintenance has an observation hole if it is green to prove that the battery is normal if it is black to prove that the battery does not save electricity. There is to observe whether there is liquid exudation, if any, proved to be bad. Finally, you can touch the hand, such as feeling the battery around the plane has proved proof bad.
- Q: What are the hazards of battery over discharge?
- Excessive discharge can seriously damage the battery's electrical performance and cycle life.
- Q: Maintenance-free battery how to detect it?
- Do not always check the color of the electric eye for maintenance-free batteries. Green for the full power; black for the lack of electricity, need to be added to charge; gray or light yellow for the electrolyte is insufficient, because maintenance-free battery can not add liquid, should immediately replace the battery.
- Q: What kind of battery is divided into?
- At present, we used the car battery is divided into three categories, namely, ordinary batteries, dry batteries and maintenance-free batteries three.
- Q: What is a maintenanceable battery?
- It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
- Q: How does battery activation work?
- If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
- Q: Lead-acid battery how to maintain?
- When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Send your message to us
LFP Battery Energy Storage System CFE-POWERSTORM AC 1200W 1800W 3.7V 282000mAh 3.7V 451200mAh
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 unit
- Supply Capability:
- 10000000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches