Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
10000000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

LFP Battery Energy Storage System CFE-48150T 48V 150Ah Lithium-ion Battery for Telecom


1、Intelligent design: universal matching, precise SOC, simple operation and maintenance, and multiple protection systems, low temperature charging and self-heating function

2、High reliability design: Integrated BMS design, long service life

3、High-density design: 4U high




  • Product Description

  • Product Spec

    Item

    CFE-48150T

    1. Performance parameters


    Model

    15S

    Nominal Voltage

    48V

    Nominal Capacity

    150Ah(0.2C to 40V at 25 )

    Operating Voltage Range

    40V-56.4V

    Boost charge/Float charge voltage 

    54.5V/52.5V

    Charging current (current-limiting )

    10A

    Continuous Charge Current 

    100A

    Continuous Discharge Current 

    100A

    Discharge Cut-off Voltage 

    40V

    Dimensions

    Width

    442±1mm

    Height

    177±1mm

    Depth 

    550±1mm

    Weight

    55±1kg

    2. Function Description


    Installation Method

    Rack Mounted

    Communication Interface 

    RS232/RS485*2/Dry Contact*2

    Indicator State

    ALM/RUN/SOC

    Parallel Communication 

    Maximum support for 15 sets of parallel

    Terminal Stud

    M6

    Alarm and Protection

    Over voltage, under voltage, short circuit, overload, over current, over temperature, low temperature protection,etc.

    3. Working Condition


    Cooling Type 

    Self-cooling

    Altitude 

    ≤2000m

    Humidity 

    5%-95%

    Operating

    Temperature

    Charge 

    0ºC to 45ºC

    Discharge 

    -5ºC to 50ºC


FAQ

CFE Lithium-ion Battery




Q: What kind of battery you can provide?

A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.

    b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).

    c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.

    d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.

    e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).

    f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.


Q: What is the capacity of production?

A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.


Q:How long is the warranty period?

A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.


Q: How long is the estimated delivery time?

A: The delivery time is within 25 days after receiving the payment.


Q: Are you able to handle shipment transportation?

A: We can arrange the shipment to most places as required.


Q: What kind of certification do you have?

A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.


Q: What kind of product quality your factory offer?

A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .


Q: Can we print our logo on products?

A: We can provide one to one customized OEM with a MOQ demand.


Q: What is the validity of the quotation?

A: Due to the raw material price fluctuation, the quotation validity is 10 days.


Q:Maintenance-free battery how to detect it?
Check the height of the electrolyte at least once a month. There is no mark line of the battery, the electrolyte added to the plate 10-15mm can be higher; there are two red line of the battery, the electrolyte can not exceed the red line above.
Q:How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q:Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.
Q:What battery does the van use?
General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
Q:How does battery activation work?
If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
Q:How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q:What are the hazards of battery over discharge?
Crystalline conductivity is poor, and bulky, will clog the pores of the battery plate, affecting the battery electrolyte penetration and exchange, but also further increase the battery resistance, a long time will prevent the battery power and chemical energy Of the reversible conversion, resulting in poor recovery of the battery charge, the battery was seriously damaged, or even unable to repair until scrapped.
Q:How should the battery be well maintained?
Electrolyte density This is to evaluate whether the battery charge is normal, whether the aging of the important parameters, the use of density meter or electrolyte density tester can be measured. If the electrolyte density is too small, you need to charge. And the electrolyte concentration is too thick or too thin to a certain extent, it means that such as the occurrence of plate vulcanization, short circuit or overcharge phenomenon, this time on the need for maintenance.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords